{"id":1297,"date":"2026-04-29T10:02:18","date_gmt":"2026-04-29T02:02:18","guid":{"rendered":"https:\/\/w6pown520g.wpdns.site\/?post_type=product&#038;p=1297"},"modified":"2026-06-29T15:23:16","modified_gmt":"2026-06-29T07:23:16","slug":"bsmjparallel-series-self-healing-low-voltage-parallel-capacitors","status":"publish","type":"product","link":"https:\/\/cnbygele.com\/es\/product\/bsmjparallel-series-self-healing-low-voltage-parallel-capacitors\/","title":{"rendered":"Condensadores paralelos de baja tensi\u00f3n auto-recuperables de la serie BSMJ (Paralelo)"},"content":{"rendered":"<h2><strong><b>Descripci\u00f3n del producto<\/b><\/strong><\/h2>\n<p>Los condensadores en paralelo de baja tensi\u00f3n autorregenerables son adecuados para sistemas de energ\u00eda con frecuencias de 50 Hz o 60 Hz. Se utilizan principalmente para mejorar el factor de potencia, reducir la p\u00e9rdida de energ\u00eda reactiva, mejorar la calidad del voltaje y aprovechar la capacidad del transformador. Es el mejor producto de bajo consumo recomendado firmemente por el pa\u00eds para su uso.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1048\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.BSMJ_.webp\" alt=\"\" width=\"1524\" height=\"824\" \/><\/p>\n<h2>Indicadores t\u00e9cnicos del producto<\/h2>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"228\">Proyecto<\/td>\n<td width=\"440\">Par\u00e1metro<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" width=\"75\">Condiciones<br \/>\nde Uso<\/td>\n<td>Temperatura ambiente<\/td>\n<td>-25\u2103~+50\u2103<\/td>\n<\/tr>\n<tr>\n<td>Humedad relativa<\/td>\n<td>85%<\/td>\n<\/tr>\n<tr>\n<td>Actitud<\/td>\n<td>\u22642000m<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Tensi\u00f3n nominal<\/td>\n<td>250VAC, 400VAC, 450VAC, 525VAC, 690VAC, 750VAC, 1050VAC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Capacidad nominal<\/td>\n<td>1-100kvar<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Tolerancia de capacidad<\/td>\n<td>-5~+10%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Valor de la tangente del \u00e1ngulo de p\u00e9rdidas<\/td>\n<td>A la tensi\u00f3n nominal a frecuencia de red, tg 6 \u2264 0,11 TP3T a 20 \u2103<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Tensi\u00f3n soportada de CA<\/td>\n<td width=\"440\">2,15 veces la tensi\u00f3n nominal entre polos durante 10 segundos, y 3 kV<br \/>\nentre postes durante 10 segundos<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Sobretensi\u00f3n m\u00e1xima permitida<\/td>\n<td>1,1 veces la tensi\u00f3n nominal<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">M\u00e1xima corriente de sobrecarga admisible<\/td>\n<td>1,30 veces la corriente nominal<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Caracter\u00edsticas de autodescarga<\/td>\n<td width=\"440\">A\u00f1ade un voltaje de CC de \u221a2 al condensador, desconecta la fuente de alimentaci\u00f3n para<br \/>\n3 minutos, y el voltaje restante disminuye en 75V o menos<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Cumple con las normas<\/td>\n<td>GB12747-2017\u3001IEC60831-2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimensiones del producto<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1050\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/8.BSMJ_.webp\" alt=\"\" width=\"1920\" height=\"1950\" \/><\/p>\n<h2>Especificaciones principales<\/h2>\n<table>\n<tbody>\n<tr>\n<td width=\"97\">Modelo de producto<\/td>\n<td width=\"89\">Calificado<br \/>\ntensi\u00f3n (kV)<\/td>\n<td width=\"110\">Calificado<br \/>\ncapacidad (kvar)<\/td>\n<td width=\"117\">Electricidad total<br \/>\ncapacidad (u F)<\/td>\n<td width=\"82\">Calificado<br \/>\ncorriente (A)<\/td>\n<td width=\"131\">Dimensi\u00f3n del l\u00edmite<br \/>\nLa x An x Al (mm)<\/td>\n<\/tr>\n<tr>\n<td>0.25-3-3YN<\/td>\n<td>0.25<\/td>\n<td>3<\/td>\n<td>153<\/td>\n<td>4<\/td>\n<td>-170x60x125<\/td>\n<\/tr>\n<tr>\n<td>0.25-5-3YN<\/td>\n<td>0.25<\/td>\n<td>5<\/td>\n<td>255<\/td>\n<td>6.7<\/td>\n<td>170x60x125<\/td>\n<\/tr>\n<tr>\n<td>0.25-7.5-3YN<\/td>\n<td>0.25<\/td>\n<td>7.5<\/td>\n<td>382<\/td>\n<td>10<\/td>\n<td>170x60x125<\/td>\n<\/tr>\n<tr>\n<td>0.25-10-3YN<\/td>\n<td>0.25<\/td>\n<td>10<\/td>\n<td>509<\/td>\n<td>13.3<\/td>\n<td>170x60x125<\/td>\n<\/tr>\n<tr>\n<td>0.25-15-3YN<\/td>\n<td>0.25<\/td>\n<td>15<\/td>\n<td>764<\/td>\n<td>20<\/td>\n<td>170x89x200<\/td>\n<\/tr>\n<tr>\n<td>0.25-20-3YN<\/td>\n<td>0.25<\/td>\n<td>20<\/td>\n<td>1019<\/td>\n<td>26.7<\/td>\n<td>170x89x245<\/td>\n<\/tr>\n<tr>\n<td>0.25-25-3YN<\/td>\n<td>0.25<\/td>\n<td>25<\/td>\n<td>1273<\/td>\n<td>33.3<\/td>\n<td>170x89x300<\/td>\n<\/tr>\n<tr>\n<td>0.25-30-3YN<\/td>\n<td>0.25<\/td>\n<td>30<\/td>\n<td>1528<\/td>\n<td>40<\/td>\n<td>170x89x300<\/td>\n<\/tr>\n<tr>\n<td>0.45-5-3<\/td>\n<td>0.45<\/td>\n<td>5<\/td>\n<td>79<\/td>\n<td>6.4<\/td>\n<td>170x60x105<\/td>\n<\/tr>\n<tr>\n<td>0.45-6-3<\/td>\n<td>0.45<\/td>\n<td>6<\/td>\n<td>94<\/td>\n<td>7.7<\/td>\n<td>170x60x105<\/td>\n<\/tr>\n<tr>\n<td>0.45-7-3<\/td>\n<td>0.45<\/td>\n<td>7<\/td>\n<td>110<\/td>\n<td>9<\/td>\n<td>170x60x105<\/td>\n<\/tr>\n<tr>\n<td>0.45-7.5-3<\/td>\n<td>0.45<\/td>\n<td>7.5<\/td>\n<td>118<\/td>\n<td>9.6<\/td>\n<td>170x60x105<\/td>\n<\/tr>\n<tr>\n<td>0.45-8-3<\/td>\n<td>0.45<\/td>\n<td>8<\/td>\n<td>126<\/td>\n<td>10.3<\/td>\n<td>170x60x105<\/td>\n<\/tr>\n<tr>\n<td>0.45-10-3<\/td>\n<td>0.45<\/td>\n<td>10<\/td>\n<td>157<\/td>\n<td>12.8<\/td>\n<td>170x60x125<\/td>\n<\/tr>\n<tr>\n<td>0.45-12-3<\/td>\n<td>0.45<\/td>\n<td>12<\/td>\n<td>189<\/td>\n<td>15.4<\/td>\n<td>170x60x175<\/td>\n<\/tr>\n<tr>\n<td>0.45-14-3<\/td>\n<td>0.45<\/td>\n<td>14<\/td>\n<td>220<\/td>\n<td>18<\/td>\n<td>170x60x175<\/td>\n<\/tr>\n<tr>\n<td>0.45-15-3<\/td>\n<td>0.45<\/td>\n<td>15<\/td>\n<td>236<\/td>\n<td>19.2<\/td>\n<td>170x60x175<\/td>\n<\/tr>\n<tr>\n<td>0.45-16-3<\/td>\n<td>0.45<\/td>\n<td>16<\/td>\n<td>252<\/td>\n<td>20.5<\/td>\n<td>170x60x175<\/td>\n<\/tr>\n<tr>\n<td>0.45-18-3<\/td>\n<td>0.45<\/td>\n<td>18<\/td>\n<td>283<\/td>\n<td>23.1<\/td>\n<td>170x60x210<\/td>\n<\/tr>\n<tr>\n<td>0.45-20-3<\/td>\n<td>0.45<\/td>\n<td>20<\/td>\n<td>314<\/td>\n<td>25.7<\/td>\n<td>170x60x210<\/td>\n<\/tr>\n<tr>\n<td>0.45-25-3<\/td>\n<td>0.45<\/td>\n<td>25<\/td>\n<td>393<\/td>\n<td>32.1<\/td>\n<td>170x89x200<\/td>\n<\/tr>\n<tr>\n<td>0.45-30-3<\/td>\n<td>0.45<\/td>\n<td>30<\/td>\n<td>472<\/td>\n<td>38.5<\/td>\n<td>170x89x200<\/td>\n<\/tr>\n<tr>\n<td>0.45-40-3<\/td>\n<td>0.45<\/td>\n<td>40<\/td>\n<td>629<\/td>\n<td>51.3<\/td>\n<td>170x89x245<\/td>\n<\/tr>\n<tr>\n<td>0.45-50-3<\/td>\n<td>0.45<\/td>\n<td>50<\/td>\n<td>786<\/td>\n<td>64.2<\/td>\n<td>170x89x300<\/td>\n<\/tr>\n<tr>\n<td>0.45-60-3<\/td>\n<td>0.45<\/td>\n<td>60<\/td>\n<td>943<\/td>\n<td>77<\/td>\n<td>270x120x250<\/td>\n<\/tr>\n<tr>\n<td>0.45-70-3<\/td>\n<td>0.45<\/td>\n<td>20<\/td>\n<td>1100<\/td>\n<td>89.8<\/td>\n<td>270x120x300<\/td>\n<\/tr>\n<tr>\n<td>0.45-80-3<\/td>\n<td>0.45<\/td>\n<td>80<\/td>\n<td>1258<\/td>\n<td>102.6<\/td>\n<td>270x120x300<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Instrucciones<\/h2>\n<p><strong>Instrucciones de uso<\/strong><\/p>\n<ul>\n<li>Transportar en el embalaje original de f\u00e1brica; manipular con cuidado.<\/li>\n<li>Almacenar en un entorno interior con gas seco y no corrosivo.<\/li>\n<\/ul>\n<p><strong>Inspecci\u00f3n de aceptaci\u00f3n del usuario<\/strong><\/p>\n<ul>\n<li>Compruebe que el modelo de la placa de caracter\u00edsticas coincide con el producto adquirido antes de usarlo.<\/li>\n<li>Prueba de capacidad: Realizarla seg\u00fan lo indicado en el punto 4.2, utilizando instrumentos con un error relativo \u22642%.<\/li>\n<li>Prueba de tensi\u00f3n de resistencia: Aplicar 75% de la tensi\u00f3n especificada en el apartado 4.3.<\/li>\n<\/ul>\n<p><strong>Instalaci\u00f3n y operaci\u00f3n<\/strong><\/p>\n<ul>\n<li>Instalar en interiores, para uso a una altitud inferior a 2000 m.<\/li>\n<li>Temperatura ambiente: -25 a +50 \u2103; humedad: &lt;85%; versi\u00f3n para bajas temperaturas (-40 a +50 \u2103) disponible bajo pedido.<\/li>\n<li>Sitio de instalaci\u00f3n: evitar la luz solar directa, la lluvia, el polvo excesivo y las vibraciones severas; separaci\u00f3n &gt;30 mm; garantizar una buena ventilaci\u00f3n y disipaci\u00f3n de calor en las altas temperaturas del verano.<\/li>\n<li>Antes de la instalaci\u00f3n, considere la elevaci\u00f3n de tensi\u00f3n despu\u00e9s de la entrada del condensador para evitar el funcionamiento a largo plazo bajo sobretensi\u00f3n; compruebe la forma de onda de la tensi\u00f3n y las caracter\u00edsticas de la red; tome medidas para limitar los arm\u00f3nicos si existen fuentes arm\u00f3nicas.<\/li>\n<li>Cuando se conecta en paralelo con un motor de inducci\u00f3n, la corriente del condensador es inferior al 90% de la corriente en vac\u00edo del motor.<\/li>\n<li>Utilice cables de cobre flexibles para los terminales de l\u00ednea y puesta a tierra, asegure un buen contacto; revise los terminales regularmente para evitar da\u00f1os.<\/li>\n<li>Intervalo entre desconexi\u00f3n y reconexi\u00f3n &gt;3 min (tiempo de autodescarga) para evitar da\u00f1os por sobretensi\u00f3n.<\/li>\n<\/ul>\n<p><strong>Instrucciones para realizar un pedido<\/strong><\/p>\n<ul>\n<li>Los usuarios deben proporcionar la tensi\u00f3n nominal, la capacidad nominal, el n\u00famero de fases y otros par\u00e1metros del producto.<\/li>\n<li>Los usuarios deben hacer todo lo posible por proporcionar algunas caracter\u00edsticas del lugar de uso.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Los condensadores paralelos de baja tensi\u00f3n con autorreparaci\u00f3n de la serie BSMJ (Parallel) son compactos y ligeros, y utilizan una pel\u00edcula de polipropileno metalizado como diel\u00e9ctrico. Ocupan solo 1\/4 del volumen y pesan 1\/5 del peso de los productos anteriores. Su gran capacidad de autorreparaci\u00f3n les permite recuperarse r\u00e1pidamente de una ruptura diel\u00e9ctrica localizada provocada por una sobretensi\u00f3n, lo que garantiza una alta fiabilidad. Estos condensadores presentan una p\u00e9rdida real inferior a 0,11 TP3T, lo que ofrece ventajas como un bajo consumo energ\u00e9tico, una baja generaci\u00f3n de calor, un bajo aumento de temperatura, una larga vida \u00fatil y un ahorro energ\u00e9tico.<\/p>","protected":false},"featured_media":1349,"template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[38,35],"product_tag":[],"class_list":["post-1297","product","type-product","status-publish","has-post-thumbnail","product_cat-power-film-capacitor","product_cat-reactive-power-compensator","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/cnbygele.com\/es\/wp-json\/wp\/v2\/product\/1297","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnbygele.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnbygele.com\/es\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/es\/wp-json\/wp\/v2\/media\/1349"}],"wp:attachment":[{"href":"https:\/\/cnbygele.com\/es\/wp-json\/wp\/v2\/media?parent=1297"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnbygele.com\/es\/wp-json\/wp\/v2\/product_brand?post=1297"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnbygele.com\/es\/wp-json\/wp\/v2\/product_cat?post=1297"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnbygele.com\/es\/wp-json\/wp\/v2\/product_tag?post=1297"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}