{"id":2322,"date":"2026-08-06T09:00:00","date_gmt":"2026-08-06T01:00:00","guid":{"rendered":"https:\/\/cnbygele.com\/blog\/mining-conveyor-vfd-harmonics-measurement\/"},"modified":"2026-08-06T09:00:00","modified_gmt":"2026-08-06T01:00:00","slug":"mining-conveyor-vfd-harmonics-measurement","status":"publish","type":"post","link":"https:\/\/cnbygele.com\/fr\/blog\/mining-conveyor-vfd-harmonics-measurement\/","title":{"rendered":"Harmoniques des variateurs de fr\u00e9quence pour convoyeurs miniers : Guide de mesure pour les alimentateurs"},"content":{"rendered":"<div class=\"b2b-article\">\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Mining conveyors run long VFD-fed strings where belt loading, crusher starts, and reclaim duty change the harmonic current seen at each feeder.<\/strong> Assessing mining conveyor VFD harmonics starts at the monitored feeder: define whether the question is local drive behavior, a substation bus, or the plant PCC, then log belt load states before any APF discussion begins.<\/p>\n<nav class=\"b2b-toc\" style=\"background:#f5f8fa;padding:16px 20px;border-radius:8px;margin:0 0 24px\">\n<h2 id=\"contents\" style=\"margin:42px 0 14px;scroll-margin-top:96px\">Contenu<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"#define-the-electrical-boundary-before-collecting-data\">D\u00e9finir la limite \u00e9lectrique avant de collecter des donn\u00e9es<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#separate-harmonic-planning-from-other-electrical-questions\">S\u00e9parer la planification harmonique des autres questions \u00e9lectriques<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#compare-mitigation-paths-without-defaulting-to-one-device\">Comparer les strat\u00e9gies d'att\u00e9nuation sans privil\u00e9gier un seul appareil<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#plan-integration-and-commissioning-early\">Planifier l'int\u00e9gration et la mise en service t\u00f4t<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#product-inquiry-and-project-boundary\">Product inquiry and project boundary<\/a><\/li>\n<\/ul>\n<\/nav>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"direct-answer\">R\u00e9ponse directe<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Mining conveyors run long VFD-fed strings where belt loading, crusher starts, and reclaim duty change the harmonic current seen at each feeder. Assessing mining conveyor VFD harmonics starts at the monitored feeder: define whether the question is local drive behavior, a substation bus, or the plant PCC, then log belt load states before any APF discussion begins.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">This matters because harmonic-current questions, reactive-power questions, voltage events, protection coordination, and equipment-operation questions can overlap without having the same technical answer. CNBYG can discuss AHF\/APF product-line context when measured harmonic current is the defined objective. It cannot establish conveyor availability targets, MSHA or site safety certification, or a guaranteed harmonic result from an article or a nameplate rating. For wider navigation, use the <a href=\"https:\/\/cnbygele.com\/fr\/power-quality-system-guides\/\">Guides d'ing\u00e9nierie des syst\u00e8mes de qualit\u00e9 de l'\u00e9nergie<\/a>.<\/p>\n<figure class=\"wp-block-image size-large\" style=\"clear:both;display:block;margin:28px 0;float:none;width:100%;\"><img decoding=\"async\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/07\/active-harmonic-filter-ahf-selection-guide-product-2.webp\" alt=\"Mining conveyor VFD harmonics assessment at feeder level\" class=\"alignnone size-large\" style=\"display:block;max-width:640px;height:auto;float:none;margin:0 auto;\" \/><\/figure>\n<p style=\"clear:both;margin:0;padding:0;height:0;line-height:0;\">&nbsp;<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"define-the-electrical-boundary-before-collecting-data\">D\u00e9finir la limite \u00e9lectrique avant de collecter des donn\u00e9es<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">La premi\u00e8re d\u00e9cision est de savoir o\u00f9 le r\u00e9sultat sera utilis\u00e9. Une mesure \u00e0 un distributeur individuel peut aider \u00e0 caract\u00e9riser une charge locale. Une mesure \u00e0 une entr\u00e9e de service, un secondaire de transformateur ou un point de couplage commun r\u00e9pond \u00e0 une question diff\u00e9rente. Enregistrez l'emplacement du compteur, l'orientation du transformateur de courant, la r\u00e9f\u00e9rence de tension, l'intervalle d'\u00e9chantillonnage, la p\u00e9riode d'agr\u00e9gation, l'\u00e9tat de fonctionnement et si d'autres charges importantes \u00e9taient actives. Sans ces d\u00e9tails, un chiffre ne peut pas \u00eatre compar\u00e9 de mani\u00e8re fiable \u00e0 un objectif de projet.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">For belt conveyor, crusher, and reclaim VFD feeders in mining plants, create an operating log that identifies empty belt, fully loaded belt, acceleration and deceleration, crusher start coincidence, and maintenance bypass. The log should make clear when the monitored load is active and what else is connected to the same bus. Record whether crushers and reclaimers were running during each capture window, because their VFD stacks can dominate the feeder spectrum.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Un enregistrement de mesure utile avant l'appel d'offres couvre normalement ces \u00e9l\u00e9ments :<\/p>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\">Le sch\u00e9ma unifilaire indiquant la position de chaque compteur, avec le rapport du TC et la polarit\u00e9 not\u00e9s.<\/li>\n<li style=\"margin:0 0 8px\">Spectres de tension et de courant captur\u00e9s \u00e0 des intervalles d'agr\u00e9gation d\u00e9finis, et non \u00e0 des instantan\u00e9s uniques.<\/li>\n<li style=\"margin:0 0 8px\">A time-stamped operating log linking each measurement window to the belt load and crusher operating state.<\/li>\n<li style=\"margin:0 0 8px\">Inventaire existant de condensateurs, de r\u00e9actances, de filtres et de variateurs sur le m\u00eame bus.<\/li>\n<li style=\"margin:0 0 8px\">La tendance de la puissance active et r\u00e9active sur au moins un cycle d'exploitation repr\u00e9sentatif.<\/li>\n<\/ul>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Question de mesure<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Entr\u00e9e de projet utile<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">D\u00e9cision qu'il soutient<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">What is occurring at the monitored conveyor or crusher feeder?<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Spectre actuel, tendance RMS, \u00e9tat de charge, emplacement du TC<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">D\u00e9pannage local et caract\u00e9risation de la source<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Que se passe-t-il \u00e0 la fronti\u00e8re du syst\u00e8me ?<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Tendances de la tension\/du courant, demande, transformateur et donn\u00e9es en amont<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u00c9valuation au niveau du syst\u00e8me et d\u00e9finition des objectifs<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Is the condition repeatable across shift and production cycles?<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Journal d'exploitation horodat\u00e9 et p\u00e9riodes repr\u00e9sentatives multiples<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Planification de la capacit\u00e9 et de la mise en service<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Quel \u00e9quipement est d\u00e9j\u00e0 connect\u00e9 ?<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">D\u00e9tails de ligne unique, condensateur\/r\u00e9acteur\/filtre et protection<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Examen de l'interaction et de l'int\u00e9gration<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Important :<\/strong> Do not treat a single feeder measurement as representative of the whole mine site without logging belt load and crusher coincidence states (Source: <a href=\"https:\/\/cnbygele.com\/fr\/blog\/vfd-harmonics-industrial-plants-apf-selection\/\">Mesure des harmoniques VFD et s\u00e9lection APF<\/a>). Crusher and reclaim VFD stacks can dominate the feeder spectrum during overlapping operating windows.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"separate-harmonic-planning-from-other-electrical-questions\">S\u00e9parer la planification harmonique des autres questions \u00e9lectriques<\/h2>\n<figure class=\"wp-block-image size-large\" style=\"clear:both;display:block;margin:28px 0;float:none;width:100%;\"><img decoding=\"async\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/07\/active-harmonic-filter-ahf-selection-guide-body-3.webp\" alt=\"Belt conveyor and crusher drive harmonic measurement context\" class=\"alignnone size-large\" style=\"display:block;max-width:640px;height:auto;float:none;margin:0 auto;\" \/><\/figure>\n<p style=\"clear:both;margin:0;padding:0;height:0;line-height:0;\">&nbsp;<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">La planification harmonique ne doit pas devenir une explication fourre-tout pour chaque pr\u00e9occupation op\u00e9rationnelle. Une lecture de forme d'onde peut exister \u00e0 c\u00f4t\u00e9 de variations de tension, de demande de puissance r\u00e9active, de d\u00e9s\u00e9quilibres, d'\u00e9v\u00e9nements de commutation ou d'une perturbation en amont. Chaque probl\u00e8me n\u00e9cessite ses propres preuves et sa propre m\u00e9thode d'acceptation. Une recommandation faite avant cette s\u00e9paration peut cr\u00e9er une port\u00e9e incorrecte, en particulier lorsque l'installation comprend un \u00e9quipement de compensation existant ou plusieurs sources de courant non lin\u00e9aire.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">La <a href=\"https:\/\/standards.ieee.org\/ieee\/519\/5892\/\" rel=\"nofollow noopener\" target=\"_blank\">Aper\u00e7u de la norme IEEE 519<\/a> est un contexte utile pour discuter du contr\u00f4le harmonique aux limites du syst\u00e8me, mais ce n'est pas une r\u00e8gle universelle pour le dimensionnement des dispositifs. Les \u00e9quipes de projet doivent \u00e9tablir le point d'application, l'ensemble de donn\u00e9es, les conditions du r\u00e9seau et les exigences contractuelles. De m\u00eame, un article ne peut pas confirmer que la condition mesur\u00e9e cause un \u00e9v\u00e9nement op\u00e9rationnel particulier. Utilisez des mesures sur site et le processus d'ing\u00e9nierie responsable pour \u00e9tablir cette relation.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"compare-mitigation-paths-without-defaulting-to-one-device\">Comparer les strat\u00e9gies d'att\u00e9nuation sans privil\u00e9gier un seul appareil<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Le chemin d'att\u00e9nuation suit l'objectif d\u00e9fini. Une option ne doit \u00eatre pr\u00e9s\u00e9lectionn\u00e9e que lorsque le relev\u00e9 de mesure la justifie et que la conception d'int\u00e9gration est comprise. Aucun appareil unique n'est automatiquement la bonne r\u00e9ponse pour chaque lecture de distorsion, cible de puissance r\u00e9active, \u00e9v\u00e9nement de tension ou r\u00e9sultat d'\u00e9tude de syst\u00e8me. Les bancs de condensateurs existants, les r\u00e9acteurs, les filtres, les variateurs, l'imp\u00e9dance des transformateurs, la protection et les variations de charge attendues affectent tous l'examen du projet.<\/p>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Cat\u00e9gorie d'option<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Peut \u00eatre envisag\u00e9 lorsque<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Doit \u00eatre confirm\u00e9 avant la s\u00e9lection<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">AHF \/ APF<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Harmonic-current mitigation at the mining plant distribution bus or PCC is a defined, measured objective<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Profil actuel, emplacement d'installation, plan CT, base de capacit\u00e9, protection, chaleur et m\u00e9thode d'acceptation<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">SVG \/ ASVG<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Le comportement dynamique de la puissance r\u00e9active est l'objectif principal d\u00e9fini.<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Profil de puissance r\u00e9active, contexte de tension, \u00e9quipements existants, commandes et limites de mise en service<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Composants passifs<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">L'\u00e9tude du syst\u00e8me identifie une fonction fixe ou accord\u00e9e appropri\u00e9e<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Risque de r\u00e9sonance, commutation, donn\u00e9es r\u00e9seau, protection et installation physique<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Changement op\u00e9rationnel ou en amont<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">La configuration de la source, du calendrier ou de la distribution est essentielle<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Responsabilit\u00e9s du propri\u00e9taire, coordination des services publics et chemin d'impl\u00e9mentation document\u00e9<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\">Pour une discussion sur la gamme de produits, voir le <a href=\"https:\/\/cnbygele.com\/fr\/produit\/ahf-active-harmonic-filter-harmonic-control\/\">Filtre Harmonique Actif CNBYG AHF page<\/a>. Il doit \u00eatre utilis\u00e9 avec les donn\u00e9es du projet, non comme un substitut \u00e0 l'\u00e9tude. Le guide associ\u00e9 sur <a href=\"https:\/\/cnbygele.com\/fr\/blog\/vfd-harmonics-industrial-plants-apf-selection\/\">Mesure des harmoniques VFD et s\u00e9lection APF<\/a> explique la m\u00eame approche ax\u00e9e sur la mesure dans un contexte d'application voisin.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"plan-integration-and-commissioning-early\">Planifier l'int\u00e9gration et la mise en service t\u00f4t<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Les questions d'int\u00e9gration doivent \u00eatre identifi\u00e9es avant l'\u00e9mission d'une demande de devis (RFQ). L'\u00e9quipe doit documenter l'emplacement de connexion propos\u00e9, la configuration des transformateurs de courant (TC), la configuration des feeders et des jeux de barres, l'espace disponible, le routage des c\u00e2bles, la ventilation, les conditions environnementales, l'acc\u00e8s, les communications, les alarmes et les attentes en mati\u00e8re de maintenance. La coordination de la protection et les exigences d'arr\u00eat doivent \u00e9galement faire l'objet d'un examen sp\u00e9cifique au projet. Ce sont des \u00e9l\u00e9ments de conception, pas des d\u00e9tails \u00e0 reporter jusqu'\u00e0 l'arriv\u00e9e du mat\u00e9riel.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">La mise en service devrait comparer les conditions repr\u00e9sentatives post-installation avec la base de r\u00e9f\u00e9rence convenue et la m\u00e9thode d'acceptation d\u00e9finie. Gardez les conditions d'exploitation comparables : enregistrez les charges principales en fonctionnement, l'emplacement des compteurs et les param\u00e8tres de mesure utilis\u00e9s. Si l'objectif du site inclut une m\u00e9trique de fronti\u00e8re de syst\u00e8me, le plan de mesure doit conserver cette fronti\u00e8re. Une position de compteur diff\u00e9rente ou un \u00e9tat de charge diff\u00e9rent peut produire un r\u00e9sultat diff\u00e9rent sans d\u00e9montrer un changement dans les performances de l'\u00e9quipement. Le guide sur <a href=\"https:\/\/cnbygele.com\/fr\/blog\/oil-gas-esp-vfd-harmonics-mitigation\/\">oil and gas ESP VFD harmonics mitigation<\/a> montre comment la m\u00eame discipline de mise en service s'applique dans un sc\u00e9nario connexe.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"product-inquiry-and-project-boundary\">Product inquiry and project boundary<\/h2>\n<figure class=\"wp-block-image size-large\" style=\"clear:both;display:block;margin:28px 0;float:none;width:100%;\"><img decoding=\"async\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/07\/active-harmonic-filter-ahf-selection-guide-cover-3.webp\" alt=\"CNBYG AHF product context for mining plant VFD feeders\" class=\"alignnone size-large\" style=\"display:block;max-width:640px;height:auto;float:none;margin:0 auto;\" \/><\/figure>\n<p style=\"clear:both;margin:0;padding:0;height:0;line-height:0;\">&nbsp;<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Une demande est plus utile lorsqu'elle contient le sch\u00e9ma unifilaire, la tension et la fr\u00e9quence nominales, les informations sur les transformateurs, les donn\u00e9es repr\u00e9sentatives de tension\/courant, le calendrier d'exploitation, l'inventaire des charges, les condensateurs\/r\u00e9actances\/filtres existants, les informations de protection, le point d'installation propos\u00e9, les donn\u00e9es d'espace et de refroidissement, et les exigences de communication. D\u00e9crivez la d\u00e9cision requise : d\u00e9pannage local, \u00e9valuation de la limite du syst\u00e8me, att\u00e9nuation des courants harmoniques, r\u00e9ponse de la puissance r\u00e9active, ou examen coordonn\u00e9.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">CNBYG can review these inputs and discuss whether its product line fits the stated scope. It should not be asked to promise conveyor availability targets, MSHA or site safety certification, or a guaranteed harmonic result. Where a project has regulated, critical, or unusual operating constraints, involve the relevant owner, system engineer, utility, and equipment specialists. Use the <a href=\"https:\/\/cnbygele.com\/fr\/contact-us\/\">Page de contact CNBYG<\/a> soumettre les informations disponibles sur le projet.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"frequently-asked-questions\">Foire aux questions<\/h2>\n<h3 style=\"margin:28px 0 12px\">Where should mining conveyor VFD harmonics be measured first?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Start at the feeder serving the conveyor or crusher group, then add the substation or PCC if the project objective is plant-level mitigation rather than local troubleshooting.<\/p>\n<h3 style=\"margin:28px 0 12px\">Do empty and loaded belt states produce different harmonic profiles?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Yes. Torque demand and regenerative behavior change with belt loading, so the operating log must label each measurement window with load state.<\/p>\n<h3 style=\"margin:28px 0 12px\">Can one conveyor feeder measurement represent the whole mine site?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Rarely. Long conveyor strings, multiple substations, and mobile equipment create different buses that need separate records or explicit scope limits.<\/p>\n<h3 style=\"margin:28px 0 12px\">Une seule mesure est-elle suffisante pour s\u00e9lectionner le mat\u00e9riel d'att\u00e9nuation ?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">G\u00e9n\u00e9ralement non. L'emplacement de la mesure, les conditions de fonctionnement, la dur\u00e9e, la topologie \u00e9lectrique et l'objectif du projet d\u00e9terminent si les donn\u00e9es sont repr\u00e9sentatives.<\/p>\n<h3 style=\"margin:28px 0 12px\">Peut-on dimensionner le mat\u00e9riel de mitigation en se basant uniquement sur la charge connect\u00e9e ?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Non. une discussion sur la capacit\u00e9 n\u00e9cessite le comportement actuel mesur\u00e9, un profil de fonctionnement, la topologie d\u2019installation et un objectif de projet d\u00e9fini.<\/p>\n<h3 style=\"margin:28px 0 12px\">Cet article garantit-il un r\u00e9sultat de conformit\u00e9 ou op\u00e9rationnel ?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Non. L'application des normes, les conditions du r\u00e9seau, les crit\u00e8res d'acceptation et la mise en service doivent \u00eatre d\u00e9finis et v\u00e9rifi\u00e9s pour le projet sp\u00e9cifique.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"references\">R\u00e9f\u00e9rences<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/standards.ieee.org\/ieee\/519\/5892\/\" rel=\"nofollow noopener\" target=\"_blank\">IEEE 519 \u2014 Pratiques recommand\u00e9es et exigences pour le contr\u00f4le des harmoniques dans les syst\u00e8mes de puissance \u00e9lectrique<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/www.nema.org\/standards\/view\/motors-and-generators\" rel=\"nofollow noopener\" target=\"_blank\">NEMA MG 1 \u2014 Moteurs et G\u00e9n\u00e9rateurs<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/www.energy.gov\/eere\/amo\/industrial-efficiency-and-decarbonization-office\" rel=\"nofollow noopener\" target=\"_blank\">D\u00e9partement de l'\u00c9nergie des \u00c9tats-Unis \u2014 Bureau de l'efficacit\u00e9 industrielle et de la d\u00e9carbonisation<\/a><\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Mining conveyors run long VFD-fed strings where belt loading, crusher starts, and reclaim duty change the harmonic current seen at each feeder. Assessing mining conveyor VFD harmonics starts at the monitored feeder: define whether the question is local drive behavior, a substation bus, or the plant PCC, then log belt load states before any APF [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":1975,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-2322","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":7}},"acf":[],"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/cnbygele.com\/fr\/wp-json\/wp\/v2\/posts\/2322","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnbygele.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cnbygele.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/fr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/fr\/wp-json\/wp\/v2\/comments?post=2322"}],"version-history":[{"count":0,"href":"https:\/\/cnbygele.com\/fr\/wp-json\/wp\/v2\/posts\/2322\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/fr\/wp-json\/wp\/v2\/media\/1975"}],"wp:attachment":[{"href":"https:\/\/cnbygele.com\/fr\/wp-json\/wp\/v2\/media?parent=2322"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cnbygele.com\/fr\/wp-json\/wp\/v2\/categories?post=2322"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cnbygele.com\/fr\/wp-json\/wp\/v2\/tags?post=2322"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}