{"id":1296,"date":"2026-04-29T10:02:18","date_gmt":"2026-04-29T02:02:18","guid":{"rendered":"https:\/\/w6pown520g.wpdns.site\/?post_type=product&#038;p=1296"},"modified":"2026-05-19T11:45:23","modified_gmt":"2026-05-19T03:45:23","slug":"jkw-series-reactive-power-automatic-compensation-controller","status":"publish","type":"product","link":"https:\/\/cnbygele.com\/fr\/product\/jkw-series-reactive-power-automatic-compensation-controller\/","title":{"rendered":"Contr\u00f4leur de compensation automatique de puissance r\u00e9active s\u00e9rie JKW"},"content":{"rendered":"<h2><strong><b>Description du produit<\/b><\/strong><\/h2>\n<p>Le r\u00e9gulateur automatique de compensation de puissance r\u00e9active de la s\u00e9rie JKW (ci-apr\u00e8s d\u00e9nomm\u00e9 le r\u00e9gulateur) est un \u00e9quipement sp\u00e9cialis\u00e9 pour la compensation de la puissance r\u00e9active dans les syst\u00e8mes de distribution basse tension, con\u00e7u conform\u00e9ment \u00e0 la norme industrielle JBT9663-2013 de la R\u00e9publique populaire de Chine et \u00e0 la norme de l'industrie \u00e9lectrique DUT597-1996. Sa grandeur physique \u00e9chantillonn\u00e9e est la puissance r\u00e9active, qui pr\u00e9sente les avantages d'une conception novatrice, de fonctions multiples, de bonnes performances de contr\u00f4le et d'une fiabilit\u00e9 \u00e9lev\u00e9e. Il occupe une position de leader parmi les produits similaires en Chine et constitue un nouvel \u00e9quipement pour l'automatisation de la distribution.<\/p>\n<ul>\n<li>Adoption de la technologie d'\u00e9chantillonnage AC ;<\/li>\n<li>En utilisant le facteur de puissance fondamental et la puissance r\u00e9active fondamentale comme grandeurs physiques de contr\u00f4le, une grande pr\u00e9cision de contr\u00f4le, sans oscillations de commutation, et insensible aux harmoniques ;<\/li>\n<li>Fonctionnement num\u00e9rique de tous les param\u00e8tres de contr\u00f4le, facile \u00e0 utiliser, une \u00e9tape en place, sans perte de donn\u00e9es de panne de courant ;<\/li>\n<li>Adoption d'un contr\u00f4le d'optimisation automatique pour r\u00e9duire la fr\u00e9quence de commutation et am\u00e9liorer la dur\u00e9e de vie du syst\u00e8me ;<\/li>\n<li>Forte capacit\u00e9 anti-interf\u00e9rences, capable de supporter des impulsions d'interf\u00e9rence de 2000V directement entr\u00e9es par l'alimentation, sans plantage ni perte de donn\u00e9es, fonctionnement stable et fiable\u00a0;<\/li>\n<li>Affichage num\u00e9rique du facteur de puissance, de la puissance r\u00e9active, de la tension, du courant (c\u00f4t\u00e9 primaire), des param\u00e8tres de contr\u00f4le du r\u00e9seau \u00e9lectrique ;<\/li>\n<li>Il existe deux modes de fonctionnement : le mode facteur de puissance et le mode de commande de la puissance r\u00e9active, qui sont pratiques pour l'installation et le d\u00e9bogage par les utilisateurs ;<\/li>\n<li>Il a pour fonction de juger et d'afficher la surtension et la sous-tension, et de couper rapidement le parc de condensateurs pour emp\u00eacher le parc de condensateurs de fonctionner dans des conditions de surtension ;<\/li>\n<li>Avec fonction de verrouillage d'oscillation commutable en option (\u00e0 pr\u00e9ciser par l'utilisateur lors de la commande) ;<\/li>\n<li>Avec la fonction optionnelle de retardement de 200 secondes entre la coupure et le temps d'entr\u00e9e d'un ensemble de condensateurs, il y a un temps de d\u00e9charge suffisant apr\u00e8s la d\u00e9connexion de la batterie de condensateurs, ce qui r\u00e9duit l'impact sur le r\u00e9seau \u00e9lectrique lorsque les condensateurs sont remis en service (les utilisateurs doivent sp\u00e9cifier lors de la commande) ;<\/li>\n<li>La r\u00e9sistance d'entr\u00e9e du signal d'\u00e9chantillonnage de courant est inf\u00e9rieure \u00e0 0,05 ohm et peut \u00eatre directement extraite du circuit de mesure;<\/li>\n<li>Il existe deux modes de compensation : le facteur de puissance et la puissance r\u00e9active ;<\/li>\n<li>Le manuel utilisateur fournit un grand nombre de m\u00e9thodes de d\u00e9pannage pour faciliter l'installation et le d\u00e9bogage.<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1036\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/9.JKW_.webp\" alt=\"\" width=\"1566\" height=\"719\" \/><\/p>\n<h2><strong><b>Param\u00e8tres techniques principaux <\/b><\/strong><\/h2>\n<p><strong>Param\u00e8tres de base<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"298\">Projet<\/td>\n<td width=\"298\">Param\u00e8tre<\/td>\n<\/tr>\n<tr>\n<td>Tension nominale<\/td>\n<td>AC380\/AC220V+10%<\/td>\n<\/tr>\n<tr>\n<td>Courant nominal<\/td>\n<td>AC0-5A<\/td>\n<\/tr>\n<tr>\n<td>Fr\u00e9quence nominale<\/td>\n<td>50 Hz \u00b1 51 TP3T<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Param\u00e8tres de contr\u00f4le<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"239\">Projet<\/td>\n<td width=\"413\">Param\u00e8tre<\/td>\n<\/tr>\n<tr>\n<td>Sensibilit\u00e9<\/td>\n<td>100 mA<\/td>\n<\/tr>\n<tr>\n<td>Cible cosinus phi pr\u00e9-r\u00e9gl\u00e9<\/td>\n<td>0,70-1,00\u00a0; Pas 0,01\u00a0; Pr\u00e9r\u00e9glage d'usine 0,95<\/td>\n<\/tr>\n<tr>\n<td>D\u00e9lai de commutation<\/td>\n<td>1 seconde et 250 millisecondes<\/td>\n<\/tr>\n<tr>\n<td>Protection contre les surtensions<\/td>\n<td>380~500\/230~260V; Pas de 1V ; Hyst\u00e9r\u00e9sis 6V<\/td>\n<\/tr>\n<tr>\n<td>Protection contre la sous-tension<\/td>\n<td>340V\/180V ; Diff\u00e9rence de retour 6V<\/td>\n<\/tr>\n<tr>\n<td>Changements d'EC<\/td>\n<td>5015A~4000\/5A ; Pas de 1<\/td>\n<\/tr>\n<tr>\n<td>Capacit\u00e9 capacitive<\/td>\n<td>O~125Kvar, preset d'usine 5Kvar pour chaque branche<\/td>\n<\/tr>\n<tr>\n<td>Note de contact<\/td>\n<td>380V*5A\/220V*7A Par branche<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Pr\u00e9cision de mesure<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"298\">Projet<\/td>\n<td width=\"298\">Param\u00e8tre<\/td>\n<\/tr>\n<tr>\n<td>Tension<\/td>\n<td>\u00b11,01 TP3T<\/td>\n<\/tr>\n<tr>\n<td>Courant<\/td>\n<td>\u00b11,01 TP3T<\/td>\n<\/tr>\n<tr>\n<td>Facteur de puissance<\/td>\n<td>\u00b11,01 TP3T<\/td>\n<\/tr>\n<tr>\n<td>Puissance r\u00e9active<\/td>\n<td>\u00b12,01 TP3T<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Plage r\u00e9glable et valeurs de r\u00e9glage d'usine des param\u00e8tres de contr\u00f4le<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"101\">Code de param\u00e8tre<\/td>\n<td width=\"246\">Sens<\/td>\n<td width=\"170\">Configuration<\/td>\n<td width=\"146\">Plage r\u00e9glable<\/td>\n<\/tr>\n<tr>\n<td>PA-1<\/td>\n<td>Pr\u00e9r\u00e9glage COS<\/td>\n<td>Hyst\u00e9r\u00e9sis 0,95<\/td>\n<td>Lag 0.8-100<\/td>\n<\/tr>\n<tr>\n<td>PA-2<\/td>\n<td>D\u00e9lai pr\u00e9d\u00e9fini<\/td>\n<td>trente ans<\/td>\n<td>1-250s<\/td>\n<\/tr>\n<tr>\n<td>PA-3<\/td>\n<td>Pr\u00e9r\u00e9glage de surtension<\/td>\n<td>430V<\/td>\n<td>230~260V\/380~500V<\/td>\n<\/tr>\n<tr>\n<td>PA-4<\/td>\n<td>Pr\u00e9r\u00e9glage du circuit<\/td>\n<td>1-12<\/td>\n<td>1-12 Circuits<\/td>\n<\/tr>\n<tr>\n<td>PA-4*<\/td>\n<td>Ratio de CT pr\u00e9d\u00e9fini<\/td>\n<td>Configuration actuelle<\/td>\n<td>50~4000<\/td>\n<\/tr>\n<tr>\n<td>C-01<\/td>\n<td>Condensateur pr\u00e9-r\u00e9gl\u00e9 du 1er circuit<\/td>\n<td>Configuration actuelle<\/td>\n<td>0~150Kvar<\/td>\n<\/tr>\n<tr>\n<td>C-12<\/td>\n<td>Condensateur pr\u00e9s\u00e9lectionn\u00e9 du 12\u00e8me circuit<\/td>\n<td>Configuration actuelle<\/td>\n<td>0~150Kvar<\/td>\n<\/tr>\n<tr>\n<td>PA-5<\/td>\n<td>Couper comme pr\u00e9s\u00e9lection<\/td>\n<td>1.00<\/td>\n<td>0.70~0.70<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Remarque : En mode de contr\u00f4le de la puissance r\u00e9active<\/p>\n<p><strong>Sp\u00e9cifications Principales<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"158\">Sp\u00e9cifications du mod\u00e8le<\/td>\n<td width=\"146\">Dimension<\/td>\n<td width=\"155\">Tension nominale (kV)<\/td>\n<td width=\"155\">Fr\u00e9quence du signal<\/td>\n<\/tr>\n<tr>\n<td>JKW5C<\/td>\n<td>113x113mm<\/td>\n<td>AC220V1380V<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>JKW5B<\/td>\n<td>162x102 mm<\/td>\n<td>220 V c.a.<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>JKG2B<\/td>\n<td>162x102 mm<\/td>\n<td>AC22OV<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>JKW1B<\/td>\n<td>140x102mm<\/td>\n<td>AC220V1380V<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>JKW58<\/td>\n<td>140 x 140 mm<\/td>\n<td>AC220V1380V<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>JKWD5<\/td>\n<td>113x113mm<\/td>\n<td>220V C.A.\/380V C.A.<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>JKWF-12<\/td>\n<td>113x113mm<\/td>\n<td>AC220V<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>JKWF-16<\/td>\n<td>113x113mm<\/td>\n<td>AC22OV<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>JKWF-16<\/td>\n<td>140 x 140 mm<\/td>\n<td>AC22OV<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>RPCF-16<\/td>\n<td>113x113mm<\/td>\n<td>220 V c.a.<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td width=\"116\">Boucle<\/td>\n<td width=\"213\">Sortie<\/td>\n<td width=\"323\">M\u00e9thode de r\u00e9mun\u00e9ration<\/td>\n<\/tr>\n<tr>\n<td>boucle de 1 \u00e0 12<\/td>\n<td>\u00c9tat statique<\/td>\n<td>Suppl\u00e9mentation de Co<\/td>\n<\/tr>\n<tr>\n<td>boucle de 1 \u00e0 12<\/td>\n<td>\u00c9tat statique<\/td>\n<td>Suppl\u00e9mentation de Co<\/td>\n<\/tr>\n<tr>\n<td>boucle de 1 \u00e0 12<\/td>\n<td>\u00c9tat statique<\/td>\n<td>Suppl\u00e9mentation de Co<\/td>\n<\/tr>\n<tr>\n<td>boucle de 1 \u00e0 12<\/td>\n<td>\u00c9tat statique<\/td>\n<td>Suppl\u00e9mentation de Co<\/td>\n<\/tr>\n<tr>\n<td>boucle de 1 \u00e0 12<\/td>\n<td>\u00c9tat statique<\/td>\n<td>Suppl\u00e9mentation de Co<\/td>\n<\/tr>\n<tr>\n<td>boucle de 1 \u00e0 12<\/td>\n<td>CC12V<\/td>\n<td>Suppl\u00e9mentation de Co<\/td>\n<\/tr>\n<tr>\n<td>boucle de 1 \u00e0 12<\/td>\n<td>\u00c9tat statique\/CC 12V<\/td>\n<td>Co-compensation+sous-compensation<\/td>\n<\/tr>\n<tr>\n<td>1-16 boucle<\/td>\n<td>CC12V<\/td>\n<td>Co-compensation+sous-compensation<\/td>\n<\/tr>\n<tr>\n<td>1-16 boucle<\/td>\n<td>\u00c9tat statique<\/td>\n<td>Co-compensation+sous-compensation<\/td>\n<\/tr>\n<tr>\n<td>1-16 boucle<\/td>\n<td>\u00c9tat statique\/CC 12V<\/td>\n<td>Suppl\u00e9mentation de Co<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Mode de c\u00e2blage<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1037\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/10.JKW_-scaled.webp\" alt=\"\" width=\"772\" height=\"2560\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>Le contr\u00f4leur automatique de compensation de puissance r\u00e9active de la s\u00e9rie JKW utilise la technologie d'\u00e9chantillonnage AC, employant le facteur de puissance fondamental et la puissance r\u00e9active fondamentale comme grandeurs physiques de contr\u00f4le pour garantir une haute pr\u00e9cision de contr\u00f4le, aucune oscillation de commutation et une insensibilit\u00e9 aux harmoniques. Tous les param\u00e8tres de contr\u00f4le sont trait\u00e9s num\u00e9riquement, simplifiant l'utilisation et emp\u00eachant la perte de donn\u00e9es due aux coupures de courant. Ce contr\u00f4leur utilise un contr\u00f4le d'optimisation automatique pour r\u00e9duire la fr\u00e9quence de commutation, prolonger la dur\u00e9e de vie du syst\u00e8me et poss\u00e8de de fortes capacit\u00e9s anti-interf\u00e9rences, peut supporter des impulsions d'interf\u00e9rence de 2000V sans planter ni perdre de donn\u00e9es, assurant un fonctionnement stable et fiable.<\/p>","protected":false},"featured_media":1622,"template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[37,35],"product_tag":[],"class_list":["post-1296","product","type-product","status-publish","has-post-thumbnail","product_cat-intelligent-controller","product_cat-reactive-power-compensator","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/cnbygele.com\/fr\/wp-json\/wp\/v2\/product\/1296","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnbygele.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnbygele.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/fr\/wp-json\/wp\/v2\/media\/1622"}],"wp:attachment":[{"href":"https:\/\/cnbygele.com\/fr\/wp-json\/wp\/v2\/media?parent=1296"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnbygele.com\/fr\/wp-json\/wp\/v2\/product_brand?post=1296"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnbygele.com\/fr\/wp-json\/wp\/v2\/product_cat?post=1296"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnbygele.com\/fr\/wp-json\/wp\/v2\/product_tag?post=1296"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}