{"id":1297,"date":"2026-04-29T10:02:18","date_gmt":"2026-04-29T02:02:18","guid":{"rendered":"https:\/\/w6pown520g.wpdns.site\/?post_type=product&#038;p=1297"},"modified":"2026-05-19T11:45:59","modified_gmt":"2026-05-19T03:45:59","slug":"bsmjparallel-series-self-healing-low-voltage-parallel-capacitors","status":"publish","type":"product","link":"https:\/\/cnbygele.com\/fr\/product\/bsmjparallel-series-self-healing-low-voltage-parallel-capacitors\/","title":{"rendered":"Condensateurs Parall\u00e8les Basse Tension Auto-r\u00e9parants S\u00e9rie BSMJ"},"content":{"rendered":"<h2><strong><b>Description du produit<\/b><\/strong><\/h2>\n<p>Les condensateurs parall\u00e8les basse tension \u00e0 auto-gu\u00e9rison conviennent aux syst\u00e8mes \u00e9lectriques de fr\u00e9quences de 50 Hz ou 60 Hz. Ils sont principalement utilis\u00e9s pour am\u00e9liorer le facteur de puissance, r\u00e9duire les pertes de puissance r\u00e9active, am\u00e9liorer la qualit\u00e9 de la tension et exploiter la capacit\u00e9 des transformateurs. C'est le meilleur produit d'\u00e9conomie d'\u00e9nergie dont l'utilisation est fortement recommand\u00e9e par le pays.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1048\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.BSMJ_.webp\" alt=\"\" width=\"1524\" height=\"824\" \/><\/p>\n<h2>Indicateurs techniques du produit<\/h2>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"228\">Projet<\/td>\n<td width=\"440\">Param\u00e8tre<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" width=\"75\">Conditions<br \/>\nd'utilisation<\/td>\n<td>Temp\u00e9rature ambiante<\/td>\n<td>-25\u2103 \u00e0 +50\u2103<\/td>\n<\/tr>\n<tr>\n<td>Humidit\u00e9 relative<\/td>\n<td>85%<\/td>\n<\/tr>\n<tr>\n<td>Aitituce<\/td>\n<td>\u22642000m<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Tension nominale<\/td>\n<td>250 VCA, 400 VCA, 450 VCA, 525 VCA, 690 VCA, 750 VCA, 1050 VCA<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Capacit\u00e9 nominale<\/td>\n<td>1-100kvar<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Tol\u00e9rance de capacit\u00e9<\/td>\n<td>-5~+10%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Tangente de l'angle de perte<\/td>\n<td>\u00c0 la tension nominale \u00e0 la fr\u00e9quence du r\u00e9seau, tg 6 \u2264 0,11 TP3T \u00e0 20 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Tension de tenue en courant alternatif<\/td>\n<td width=\"440\">2,15 fois la tension nominale entre p\u00f4les pendant 10 secondes, et 3 kV<br \/>\nentre les poteaux pendant 10 secondes<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Sur-tension maximale admissible<\/td>\n<td>1,1 fois la tension nominale<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Courant de surcharge maximal autoris\u00e9<\/td>\n<td>1,30 fois le courant nominal<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Caract\u00e9ristiques de d\u00e9charge spontan\u00e9e<\/td>\n<td width=\"440\">Ajoutez \u221a2 V de tension continue au condensateur, d\u00e9branchez l'alimentation pour<br \/>\n3 minutes, et la tension restante diminue de 75 V ou moins<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Conforme aux normes<\/td>\n<td>GB12747-2017, CEI60831-2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimensions du produit<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1050\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/8.BSMJ_.webp\" alt=\"\" width=\"1920\" height=\"1950\" \/><\/p>\n<h2>Sp\u00e9cifications Principales<\/h2>\n<table>\n<tbody>\n<tr>\n<td width=\"97\">Mod\u00e8le de produit<\/td>\n<td width=\"89\">Class\u00e9<br \/>\ntension (kV)<\/td>\n<td width=\"110\">Class\u00e9<br \/>\ncapacit\u00e9 (kvar)<\/td>\n<td width=\"117\">\u00c9lectricit\u00e9 totale<br \/>\ncapacit\u00e9 (u F)<\/td>\n<td width=\"82\">Class\u00e9<br \/>\ncourant (A)<\/td>\n<td width=\"131\">Dimension limite<br \/>\nLxlxH (mm)<\/td>\n<\/tr>\n<tr>\n<td>0,25-3-3YN<\/td>\n<td>0.25<\/td>\n<td>3<\/td>\n<td>153<\/td>\n<td>4<\/td>\n<td>-170x60x125<\/td>\n<\/tr>\n<tr>\n<td>0,25-5-3YN<\/td>\n<td>0.25<\/td>\n<td>5<\/td>\n<td>255<\/td>\n<td>6.7<\/td>\n<td>170x60x125<\/td>\n<\/tr>\n<tr>\n<td>0,25-7,5-3YN<\/td>\n<td>0.25<\/td>\n<td>7.5<\/td>\n<td>382<\/td>\n<td>10<\/td>\n<td>170x60x125<\/td>\n<\/tr>\n<tr>\n<td>0,25-10-3YN<\/td>\n<td>0.25<\/td>\n<td>10<\/td>\n<td>509<\/td>\n<td>13.3<\/td>\n<td>170x60x125<\/td>\n<\/tr>\n<tr>\n<td>0,25-15-3YN<\/td>\n<td>0.25<\/td>\n<td>15<\/td>\n<td>764<\/td>\n<td>20<\/td>\n<td>170x89x200<\/td>\n<\/tr>\n<tr>\n<td>0,25-20-3YN<\/td>\n<td>0.25<\/td>\n<td>20<\/td>\n<td>1019<\/td>\n<td>26.7<\/td>\n<td>170x89x245<\/td>\n<\/tr>\n<tr>\n<td>0,25-25-3YN<\/td>\n<td>0.25<\/td>\n<td>25<\/td>\n<td>1273<\/td>\n<td>33.3<\/td>\n<td>170x89x300<\/td>\n<\/tr>\n<tr>\n<td>0.25-30-3YN<\/td>\n<td>0.25<\/td>\n<td>30<\/td>\n<td>1528<\/td>\n<td>40<\/td>\n<td>170x89x300<\/td>\n<\/tr>\n<tr>\n<td>0.45-5-3<\/td>\n<td>0.45<\/td>\n<td>5<\/td>\n<td>79<\/td>\n<td>6.4<\/td>\n<td>170x60x105<\/td>\n<\/tr>\n<tr>\n<td>0.45-6-3<\/td>\n<td>0.45<\/td>\n<td>6<\/td>\n<td>94<\/td>\n<td>7.7<\/td>\n<td>170x60x105<\/td>\n<\/tr>\n<tr>\n<td>0.45-7-3<\/td>\n<td>0.45<\/td>\n<td>7<\/td>\n<td>110<\/td>\n<td>9<\/td>\n<td>170x60x105<\/td>\n<\/tr>\n<tr>\n<td>0.45-7.5-3<\/td>\n<td>0.45<\/td>\n<td>7.5<\/td>\n<td>118<\/td>\n<td>9.6<\/td>\n<td>170x60x105<\/td>\n<\/tr>\n<tr>\n<td>0.45-8-3<\/td>\n<td>0.45<\/td>\n<td>8<\/td>\n<td>126<\/td>\n<td>10.3<\/td>\n<td>170x60x105<\/td>\n<\/tr>\n<tr>\n<td>0.45-10-3<\/td>\n<td>0.45<\/td>\n<td>10<\/td>\n<td>157<\/td>\n<td>12.8<\/td>\n<td>170x60x125<\/td>\n<\/tr>\n<tr>\n<td>0.45-12-3<\/td>\n<td>0.45<\/td>\n<td>12<\/td>\n<td>189<\/td>\n<td>15.4<\/td>\n<td>170x60x175<\/td>\n<\/tr>\n<tr>\n<td>0.45-14-3<\/td>\n<td>0.45<\/td>\n<td>14<\/td>\n<td>220<\/td>\n<td>18<\/td>\n<td>170x60x175<\/td>\n<\/tr>\n<tr>\n<td>0.45-15-3<\/td>\n<td>0.45<\/td>\n<td>15<\/td>\n<td>236<\/td>\n<td>19.2<\/td>\n<td>170x60x175<\/td>\n<\/tr>\n<tr>\n<td>0.45-16-3<\/td>\n<td>0.45<\/td>\n<td>16<\/td>\n<td>252<\/td>\n<td>20.5<\/td>\n<td>170x60x175<\/td>\n<\/tr>\n<tr>\n<td>0.45-18-3<\/td>\n<td>0.45<\/td>\n<td>18<\/td>\n<td>283<\/td>\n<td>23.1<\/td>\n<td>170x60x210<\/td>\n<\/tr>\n<tr>\n<td>0.45-20-3<\/td>\n<td>0.45<\/td>\n<td>20<\/td>\n<td>314<\/td>\n<td>25.7<\/td>\n<td>170x60x210<\/td>\n<\/tr>\n<tr>\n<td>0.45-25-3<\/td>\n<td>0.45<\/td>\n<td>25<\/td>\n<td>393<\/td>\n<td>32.1<\/td>\n<td>170x89x200<\/td>\n<\/tr>\n<tr>\n<td>0.45-30-3<\/td>\n<td>0.45<\/td>\n<td>30<\/td>\n<td>472<\/td>\n<td>38.5<\/td>\n<td>170x89x200<\/td>\n<\/tr>\n<tr>\n<td>0.45-40-3<\/td>\n<td>0.45<\/td>\n<td>40<\/td>\n<td>629<\/td>\n<td>51.3<\/td>\n<td>170x89x245<\/td>\n<\/tr>\n<tr>\n<td>0.45-50-3<\/td>\n<td>0.45<\/td>\n<td>50<\/td>\n<td>786<\/td>\n<td>64.2<\/td>\n<td>170x89x300<\/td>\n<\/tr>\n<tr>\n<td>0.45-60-3<\/td>\n<td>0.45<\/td>\n<td>60<\/td>\n<td>943<\/td>\n<td>77<\/td>\n<td>270x120x250<\/td>\n<\/tr>\n<tr>\n<td>0.45-70-3<\/td>\n<td>0.45<\/td>\n<td>20<\/td>\n<td>1100<\/td>\n<td>89.8<\/td>\n<td>270x120x300<\/td>\n<\/tr>\n<tr>\n<td>0.45-80-3<\/td>\n<td>0.45<\/td>\n<td>80<\/td>\n<td>1258<\/td>\n<td>102.6<\/td>\n<td>270x120x300<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Instructions<\/h2>\n<p><strong>Instructions d'utilisation<\/strong><\/p>\n<ul>\n<li>Transport dans son emballage d'origine en usine ; manipuler avec soin.<\/li>\n<li>Stocker dans un environnement int\u00e9rieur sec, sans gaz corrosifs.<\/li>\n<\/ul>\n<p><strong>R\u00e9ception du logiciel par l'utilisateur<\/strong><\/p>\n<ul>\n<li>V\u00e9rifiez que le mod\u00e8le de la plaque signal\u00e9tique correspond au produit achet\u00e9 avant utilisation.<\/li>\n<li>Essai de capacit\u00e9 : \u00e0 r\u00e9aliser conform\u00e9ment au point 4.2, en utilisant des instruments dont l&#x27;erreur relative est inf\u00e9rieure ou \u00e9gale \u00e0 21 TP3T.<\/li>\n<li>Essai de tension de tenue : appliquer une tension de 75%, conform\u00e9ment \u00e0 la sp\u00e9cification du paragraphe 4.3.<\/li>\n<\/ul>\n<p><strong>Installation et exploitation<\/strong><\/p>\n<ul>\n<li>Installation en int\u00e9rieur, pour usage \u00e0 une altitude inf\u00e9rieure \u00e0 2000 m.<\/li>\n<li>Temp\u00e9rature ambiante : -25 \u00e0 +50 \u00b0C, humidit\u00e9 &lt; 85 % ; version basse temp\u00e9rature (-40 \u00e0 +50 \u00b0C) disponible sur demande.<\/li>\n<li>Site d'installation : \u00e9viter la lumi\u00e8re directe du soleil, la pluie, la poussi\u00e8re excessive et les vibrations s\u00e9v\u00e8res ; espacement &gt; 30 mm ; assurer une bonne ventilation et dissipation de la chaleur par temps chaud en \u00e9t\u00e9.<\/li>\n<li>Avant l'installation, consid\u00e9rez l'augmentation de la tension apr\u00e8s l'entr\u00e9e du condensateur pour \u00e9viter un fonctionnement \u00e0 long terme sous surtension ; v\u00e9rifiez la forme d'onde de la tension et les caract\u00e9ristiques du r\u00e9seau ; prenez des mesures pour limiter les harmoniques si des sources d'harmoniques existent.<\/li>\n<li>Lorsqu&#x27;il est coupl\u00e9 \u00e0 un moteur \u00e0 induction, le courant du condensateur est inf\u00e9rieur \u00e0 90% du courant \u00e0 vide du moteur.<\/li>\n<li>Utiliser des fils de cuivre souples pour les bornes de ligne et de mise \u00e0 la terre, assurer un bon contact ; v\u00e9rifier r\u00e9guli\u00e8rement les bornes pour \u00e9viter les dommages.<\/li>\n<li>Intervalle entre d\u00e9connexion et reconnexion &gt;3min (temps d'auto-d\u00e9charge) pour \u00e9viter les dommages dus \u00e0 une surtension.<\/li>\n<\/ul>\n<p><strong>Instructions de commande<\/strong><\/p>\n<ul>\n<li>Les utilisateurs doivent fournir la tension nominale du produit, la capacit\u00e9 nominale, le nombre de phases et d'autres param\u00e8tres.<\/li>\n<li>Les utilisateurs devraient faire de leur mieux pour fournir quelques caract\u00e9ristiques du lieu d'utilisation.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Les condensateurs parall\u00e8les basse tension \u00e0 autor\u00e9g\u00e9n\u00e9ration de la s\u00e9rie BSMJ (Parallel) sont compacts et l\u00e9gers ; ils utilisent un film de polypropyl\u00e8ne m\u00e9tallis\u00e9 comme di\u00e9lectrique. Leur volume ne repr\u00e9sente qu&#x27;un quart et leur poids un cinqui\u00e8me de ceux des anciens mod\u00e8les. Leur forte capacit\u00e9 d&#x27;auto-r\u00e9paration leur permet de se remettre rapidement d&#x27;une rupture di\u00e9lectrique localis\u00e9e caus\u00e9e par une surtension, garantissant ainsi une grande fiabilit\u00e9. Ces condensateurs pr\u00e9sentent une perte r\u00e9elle inf\u00e9rieure \u00e0 0,11 TP3T, offrant des avantages tels qu&#x27;une faible consommation d&#x27;\u00e9nergie, une faible production de chaleur, une faible \u00e9l\u00e9vation de temp\u00e9rature, une longue dur\u00e9e de vie et des \u00e9conomies d&#x27;\u00e9nergie.<\/p>","protected":false},"featured_media":1349,"template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[38,35],"product_tag":[],"class_list":["post-1297","product","type-product","status-publish","has-post-thumbnail","product_cat-power-film-capacitor","product_cat-reactive-power-compensator","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/cnbygele.com\/fr\/wp-json\/wp\/v2\/product\/1297","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnbygele.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnbygele.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/fr\/wp-json\/wp\/v2\/media\/1349"}],"wp:attachment":[{"href":"https:\/\/cnbygele.com\/fr\/wp-json\/wp\/v2\/media?parent=1297"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnbygele.com\/fr\/wp-json\/wp\/v2\/product_brand?post=1297"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnbygele.com\/fr\/wp-json\/wp\/v2\/product_cat?post=1297"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnbygele.com\/fr\/wp-json\/wp\/v2\/product_tag?post=1297"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}