{"id":1689,"date":"2026-05-21T11:55:14","date_gmt":"2026-05-21T03:55:14","guid":{"rendered":"https:\/\/w6pown520g.wpdns.site\/?post_type=product&#038;p=1689"},"modified":"2026-06-29T16:02:23","modified_gmt":"2026-06-29T08:02:23","slug":"svg-static-var-generators-2","status":"publish","type":"product","link":"https:\/\/cnbygele.com\/id\/product\/svg-static-var-generators-2\/","title":{"rendered":"Generator Var Statis SVG"},"content":{"rendered":"<h2>Deskripsi Produk<\/h2>\n<p>Konsumsi daya reaktif dikenakan biaya tambahan oleh operator jaringan. Oleh karena itu, penggunaan kompensator SVG secara efektif mengurangi tagihan listrik dengan menghilangkan sepenuhnya biaya yang terkait dengan konsumsi daya reaktif.<\/p>\n<ul>\n<li>Kompensasi daya reaktif secara langsung dan akurat<\/li>\n<li>Penekanan harmonisa aktif<\/li>\n<li>Adaptasi dinamis terhadap perubahan kondisi operasi<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1609\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control.webp\" alt=\"\" width=\"1500\" height=\"872\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control.webp 1500w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-300x174.webp 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-1024x595.webp 1024w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-768x446.webp 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-600x349.webp 600w\" sizes=\"auto, (max-width: 1500px) 100vw, 1500px\" \/><\/p>\n<p><strong><b>Prinsip kerja SVG<\/b><\/strong><\/p>\n<p>Prinsip kerja kompensator SVG didasarkan pada pemantauan bentuk gelombang arus dan tegangan dalam jaringan secara terus-menerus.<\/p>\n<p>Ketika sistem mendeteksi pergeseran fase yang disebabkan oleh karakteristik beban, sistem segera menghasilkan arus kompensasi dengan karakteristik yang berlawanan. Berkat penggunaan modul IGBT Jerman dari Infineon dan kontrol PWM yang presisi, perangkat ini mengoreksi faktor daya secara real-time serta mengompensasi daya reaktif induktif maupun kapasitif. Mode operasi aktif ini memastikan parameter pasokan listrik tetap ideal terlepas dari fluktuasi beban, sehingga menjamin keandalan luar biasa dan presisi kompensasi tertinggi.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1613\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1.webp\" alt=\"\" width=\"2480\" height=\"2339\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1.webp 2480w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-300x283.webp 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-1024x966.webp 1024w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-768x724.webp 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-1536x1449.webp 1536w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-2048x1932.webp 2048w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-600x566.webp 600w\" sizes=\"auto, (max-width: 2480px) 100vw, 2480px\" \/><\/p>\n<h2><strong><b>SVG Pemasangan di Dinding<\/b><\/strong><\/h2>\n<p><strong>Spesifikasi Teknis<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"174\">KETIK<\/td>\n<td width=\"149\">Seri 230V<\/td>\n<td width=\"155\">Seri 400V<\/td>\n<td width=\"91\">Seri 500V<\/td>\n<td width=\"91\">Seri 690V<\/td>\n<\/tr>\n<tr>\n<td>Kapasitas<\/td>\n<td width=\"149\">20kVar\/30kVar\/35kVar\/<br \/>\n50kVar\/70kVar\/100kVar<\/td>\n<td width=\"155\">10kVar\/15kVar\/20kVar\/<br \/>\n30kVar\/35kVar\/50kVar\/<br \/>\n75kVar\/100kVar\/150kVar<\/td>\n<td>85 kVar<\/td>\n<td>120 kVar<\/td>\n<\/tr>\n<tr>\n<td>Tegangan<\/td>\n<td>230 V (+\/-20%)<\/td>\n<td>400 V (+\/-20%)<\/td>\n<td>500 V (+\/-201 TP3T)<\/td>\n<td>690 V (+\/-201 TP3T)<\/td>\n<\/tr>\n<tr>\n<td>Frekuensi<\/td>\n<td colspan=\"4\">50 Hz (+\/-51 TP3T)<\/td>\n<\/tr>\n<tr>\n<td>Fase<\/td>\n<td>1 Fase<\/td>\n<td colspan=\"3\">3 Fase<\/td>\n<\/tr>\n<tr>\n<td>Waktu respons<\/td>\n<td colspan=\"4\">&lt;10 ms<\/td>\n<\/tr>\n<tr>\n<td>Faktor kompensasi<\/td>\n<td colspan=\"4\">&gt;95%<\/td>\n<\/tr>\n<tr>\n<td>Efisiensi perangkat<\/td>\n<td colspan=\"4\">&gt;97%<\/td>\n<\/tr>\n<tr>\n<td>Frekuensi pensaklaran<\/td>\n<td>32 kHz<\/td>\n<td>16 kHz<\/td>\n<td>12,8 kHz<\/td>\n<td>12,8 kHz<\/td>\n<\/tr>\n<tr>\n<td>Fungsi<\/td>\n<td colspan=\"4\">Kompensasi daya reaktif<\/td>\n<\/tr>\n<tr>\n<td>Jumlah modul<\/td>\n<td colspan=\"4\" width=\"488\">Tanpa batasan. Satu modul pemantauan dapat<br \/>\ndilengkapi dengan 32 modul aktuator\/eksekusi<\/td>\n<\/tr>\n<tr>\n<td>Komunikasi<\/td>\n<td colspan=\"4\">RS485 saluran ganda (Mendukung komunikasi nirkabel WiFi\/GPRS)<\/td>\n<\/tr>\n<tr>\n<td>Ketinggian di atas permukaan laut<\/td>\n<td colspan=\"4\">&lt;2000m<\/td>\n<\/tr>\n<tr>\n<td>Suhu<\/td>\n<td colspan=\"4\">-20 hingga +50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Kelembapan<\/td>\n<td colspan=\"4\">&lt;90%<\/td>\n<\/tr>\n<tr>\n<td>Tingkat Polusi<\/td>\n<td colspan=\"4\">Di Bawah Level 2<\/td>\n<\/tr>\n<tr>\n<td>Proteksi<\/td>\n<td colspan=\"4\" width=\"488\">Beban lebih, arus lebih, tegangan lebih, terhadap ketidakseimbangan jaringan suplai,<br \/>\nTermal\/suhu berlebih, fluktuasi frekuensi, hubung singkat<\/td>\n<\/tr>\n<tr>\n<td>Kebisingan<\/td>\n<td>&lt;50dB<\/td>\n<td>&lt;60dB<\/td>\n<td colspan=\"2\">&lt;65dB<\/td>\n<\/tr>\n<tr>\n<td>Metode instalasi<\/td>\n<td colspan=\"4\">Pemasangan di Dinding<\/td>\n<\/tr>\n<tr>\n<td>Koneksi<\/td>\n<td colspan=\"4\">Dari atas (Dipasang di dinding)<\/td>\n<\/tr>\n<tr>\n<td>Derajat perlindungan<\/td>\n<td colspan=\"4\">IP20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong><b>Informasi Ukuran Produk<\/b><\/strong><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-962\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/4.SVG.webp\" alt=\"\" width=\"1500\" height=\"816\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"101\">Model<\/td>\n<td width=\"246\">Kapasitas (kvar)<\/td>\n<td width=\"71\">Tegangan (V)<\/td>\n<td width=\"113\">Ukuran (P\u00d7T\u00d7L) (mm)<\/td>\n<td width=\"133\">Pendinginan<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.23-2L-W<\/td>\n<td>20Kvar\/30Kvar\/35Kvar<\/td>\n<td>230V<\/td>\n<td>380x424x88<\/td>\n<td>Pendinginan Udara Paksa<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.23-2L-W<\/td>\n<td>50Kvar\/70Kvar\/100Kvar<\/td>\n<td>230V<\/td>\n<td>500x550x130<\/td>\n<td>Pendinginan Udara Paksa<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.4-4L-W<\/td>\n<td>10Kvar\/15Kvar\/20Kvar\/30Kvar\/35Kvar<\/td>\n<td>400V<\/td>\n<td>380x424x88<\/td>\n<td>Pendinginan Udara Paksa<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.4-4L-W<\/td>\n<td>50Kvar\/75Kvar\/100Kvar\/150Kvar<\/td>\n<td>400V<\/td>\n<td>500x550x130<\/td>\n<td>Pendinginan Udara Paksa<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.5-4L-W<\/td>\n<td>85 kVAr<\/td>\n<td>500V<\/td>\n<td>500x550x130<\/td>\n<td>Pendinginan Udara Paksa<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.69-4L-W<\/td>\n<td>120 kVAr<\/td>\n<td>690V<\/td>\n<td>500x550x130<\/td>\n<td>Pendinginan Udara Paksa<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Spesifikasi terbatas pada jenis standar; dimensi lain tersedia berdasarkan permintaan.<\/p>\n<h2><strong><b>SVG yang dipasang di rak<\/b><\/strong><\/h2>\n<p><strong>Spesifikasi Teknis<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"183\">KETIK<\/td>\n<td width=\"146\">Seri 230V<\/td>\n<td width=\"153\">Seri 400V<\/td>\n<td width=\"93\">Seri 500V<\/td>\n<td width=\"93\">Seri 690V<\/td>\n<\/tr>\n<tr>\n<td>Kapasitas<\/td>\n<td width=\"146\">20kVar\/30kVar\/35kVar\/<br \/>\n50kVar\/70kVar\/100kVar<\/td>\n<td width=\"153\">10kVar\/15kVar\/20kVar\/<br \/>\n30kVar\/35kVar\/50kVar\/<br \/>\n75kVar\/100kVar\/150kVar<\/td>\n<td>85 kVar<\/td>\n<td>120 kVar<\/td>\n<\/tr>\n<tr>\n<td>Tegangan<\/td>\n<td>230 V (+\/-20%)<\/td>\n<td>400 V (+\/-20%)<\/td>\n<td>500 V (+\/-201 TP3T)<\/td>\n<td>690 V (+\/-201 TP3T)<\/td>\n<\/tr>\n<tr>\n<td>Frekuensi<\/td>\n<td colspan=\"4\">50 Hz (+\/-51 TP3T)<\/td>\n<\/tr>\n<tr>\n<td>Fase<\/td>\n<td>1 Fase<\/td>\n<td colspan=\"3\">3 Fase<\/td>\n<\/tr>\n<tr>\n<td>Waktu respons<\/td>\n<td colspan=\"4\">&lt;10 ms<\/td>\n<\/tr>\n<tr>\n<td>Faktor kompensasi<\/td>\n<td colspan=\"4\">&gt;95%<\/td>\n<\/tr>\n<tr>\n<td>Efisiensi perangkat<\/td>\n<td colspan=\"4\">&gt;97%<\/td>\n<\/tr>\n<tr>\n<td>Frekuensi pensaklaran<\/td>\n<td>32 kHz<\/td>\n<td>16 kHz<\/td>\n<td>12,8 kHz<\/td>\n<td>12,8 kHz<\/td>\n<\/tr>\n<tr>\n<td>Fungsi<\/td>\n<td colspan=\"4\">Kompensasi daya reaktif<\/td>\n<\/tr>\n<tr>\n<td>Jumlah modul<\/td>\n<td colspan=\"4\" width=\"487\">Tanpa batasan. Satu modul pemantauan dapat<br \/>\ndilengkapi dengan 32 modul aktuator\/eksekusi<\/td>\n<\/tr>\n<tr>\n<td>Komunikasi<\/td>\n<td colspan=\"4\">RS485 saluran ganda (Mendukung komunikasi nirkabel WiFi\/GPRS)<\/td>\n<\/tr>\n<tr>\n<td>Ketinggian di atas permukaan laut<\/td>\n<td colspan=\"4\">&lt;2000m<\/td>\n<\/tr>\n<tr>\n<td>Suhu<\/td>\n<td colspan=\"4\">-20 hingga +50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Kelembapan<\/td>\n<td colspan=\"4\">&lt;90%<\/td>\n<\/tr>\n<tr>\n<td>Tingkat Polusi<\/td>\n<td colspan=\"4\">Di Bawah Level 2<\/td>\n<\/tr>\n<tr>\n<td>Proteksi<\/td>\n<td colspan=\"4\" width=\"487\">Beban lebih, arus lebih, tegangan lebih, terhadap ketidakseimbangan jaringan suplai,<br \/>\nTermal\/suhu berlebih, fluktuasi frekuensi, hubung singkat<\/td>\n<\/tr>\n<tr>\n<td>Kebisingan<\/td>\n<td>&lt;50dB<\/td>\n<td>&lt;60dB<\/td>\n<td colspan=\"2\">&lt;65dB<\/td>\n<\/tr>\n<tr>\n<td>Metode instalasi<\/td>\n<td colspan=\"4\">Pemasangan rak<\/td>\n<\/tr>\n<tr>\n<td>Koneksi<\/td>\n<td colspan=\"4\">Dari belakang (Rak)<\/td>\n<\/tr>\n<tr>\n<td>Derajat perlindungan<\/td>\n<td colspan=\"4\">IP20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><b>Informasi Ukuran Produk<\/b><\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1615\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators.webp\" alt=\"\" width=\"1500\" height=\"765\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators.webp 1500w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators-300x153.webp 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators-1024x522.webp 1024w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators-768x392.webp 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators-600x306.webp 600w\" sizes=\"auto, (max-width: 1500px) 100vw, 1500px\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"101\">Model<\/td>\n<td width=\"246\">Kapasitas (kvar)<\/td>\n<td width=\"71\">Tegangan (V)<\/td>\n<td width=\"113\">Ukuran (P\u00d7T\u00d7L) (mm)<\/td>\n<td width=\"133\">Pendinginan<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.23-2L-R<\/td>\n<td>20Kvar\/30Kvar\/35Kvar<\/td>\n<td>230V<\/td>\n<td>380x424x88<\/td>\n<td>Pendinginan Udara Paksa<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.23-2L-R<\/td>\n<td>50Kvar\/70Kvar\/100Kvar<\/td>\n<td>230V<\/td>\n<td>500x550x130<\/td>\n<td>Pendinginan Udara Paksa<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.4-4L-R<\/td>\n<td>10Kvar\/15Kvar\/20Kvar\/30Kvar\/35Kvar<\/td>\n<td>400V<\/td>\n<td>380x424x88<\/td>\n<td>Pendinginan Udara Paksa<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.4-4L-R<\/td>\n<td>50Kvar\/75Kvar\/100Kvar\/150Kvar<\/td>\n<td>400V<\/td>\n<td>500x550x130<\/td>\n<td>Pendinginan Udara Paksa<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.5-4L-R<\/td>\n<td>85 kVAr<\/td>\n<td>500V<\/td>\n<td>500x550x130<\/td>\n<td>Pendinginan Udara Paksa<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.69-4L-R<\/td>\n<td>120 kVAr<\/td>\n<td>690V<\/td>\n<td>500x550x130<\/td>\n<td>Pendinginan Udara Paksa<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Spesifikasi terbatas pada jenis standar; dimensi lain tersedia berdasarkan permintaan.<\/p>","protected":false},"excerpt":{"rendered":"<p>Kompensator daya reaktif statis (SVG) kami menyediakan solusi optimal untuk mengatasi masalah stabilitas jaringan, faktor daya, dan kebutuhan daya reaktif dalam berbagai aplikasi industri. Perangkat ini memiliki kecepatan operasi yang sangat tinggi, desain ringkas, dan efisiensi biaya yang luar biasa, sehingga mampu merespons gangguan secara langsung pada sistem tenaga listrik tegangan menengah dan rendah. Dengan mengompensasi daya reaktif, perangkat ini secara signifikan memperpanjang masa pakai instalasi, meningkatkan keandalan proses produksi, mengoptimalkan kinerja sistem, serta mengurangi rugi-rugi transmisi, sekaligus memenuhi standar kualitas energi yang paling ketat.<\/p>","protected":false},"featured_media":1606,"template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[33,30],"product_tag":[],"class_list":["post-1689","product","type-product","status-publish","has-post-thumbnail","product_cat-power-quality-system","product_cat-products","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/cnbygele.com\/id\/wp-json\/wp\/v2\/product\/1689","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnbygele.com\/id\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnbygele.com\/id\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/id\/wp-json\/wp\/v2\/media\/1606"}],"wp:attachment":[{"href":"https:\/\/cnbygele.com\/id\/wp-json\/wp\/v2\/media?parent=1689"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnbygele.com\/id\/wp-json\/wp\/v2\/product_brand?post=1689"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnbygele.com\/id\/wp-json\/wp\/v2\/product_cat?post=1689"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnbygele.com\/id\/wp-json\/wp\/v2\/product_tag?post=1689"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}