{"id":1689,"date":"2026-05-21T11:55:14","date_gmt":"2026-05-21T03:55:14","guid":{"rendered":"https:\/\/w6pown520g.wpdns.site\/?post_type=product&#038;p=1689"},"modified":"2026-06-29T16:02:23","modified_gmt":"2026-06-29T08:02:23","slug":"svg-static-var-generators-2","status":"publish","type":"product","link":"https:\/\/cnbygele.com\/id\/product\/svg-static-var-generators-2\/","title":{"rendered":"Generator Var Statis SVG"},"content":{"rendered":"<h2>Deskripsi Produk<\/h2>\n<p>The consumption of reactive power involves additional charges levied by operators, which is why the use of an SVG compensator effectively reduces electricity bills, completely eliminating the costs associated with reactive power consumption.<\/p>\n<ul>\n<li>Immediate and precise reactive power compensation<\/li>\n<li>Active harmonic suppression<\/li>\n<li>Dynamic adaptation to changing operating conditions<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1609\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control.webp\" alt=\"\" width=\"1500\" height=\"872\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control.webp 1500w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-300x174.webp 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-1024x595.webp 1024w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-768x446.webp 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-600x349.webp 600w\" sizes=\"auto, (max-width: 1500px) 100vw, 1500px\" \/><\/p>\n<p><strong><b>SVG principle of operation<\/b><\/strong><\/p>\n<p>The operating principle of the SVG compensator is based on continuously monitoring the current and voltage waveforms in the network.<\/p>\n<p>When the system detects phase deviations caused by the nature of the load, it immediately generates a compensating current with the opposite characteristics. Thanks to the use of German IGBT modules from Infineon and precise PWM control, the device corrects the power factor in real time, compensating both inductive and capacitive reactive power. This active mode of operation ensures the maintenance of ideal power supply parameters regardless of load fluctuations, guaranteeing exceptional reliability and the highest precision of compensation.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1613\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1.webp\" alt=\"\" width=\"2480\" height=\"2339\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1.webp 2480w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-300x283.webp 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-1024x966.webp 1024w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-768x724.webp 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-1536x1449.webp 1536w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-2048x1932.webp 2048w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-600x566.webp 600w\" sizes=\"auto, (max-width: 2480px) 100vw, 2480px\" \/><\/p>\n<h2><strong><b>Wall-Mounted SVG<\/b><\/strong><\/h2>\n<p><strong>Spesifikasi Teknis<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"174\">KETIK<\/td>\n<td width=\"149\">Seri 230V<\/td>\n<td width=\"155\">Seri 400V<\/td>\n<td width=\"91\">Seri 500V<\/td>\n<td width=\"91\">Seri 690V<\/td>\n<\/tr>\n<tr>\n<td>Kapasitas<\/td>\n<td width=\"149\">20kVar\/30kVar\/35kVar\/<br \/>\n50kVar\/70kVar\/100kVar<\/td>\n<td width=\"155\">10kVar\/15kVar\/20kVar\/<br \/>\n30kVar\/35kVar\/50kVar\/<br \/>\n75kVar\/100kVar\/150kVar<\/td>\n<td>85kVar<\/td>\n<td>120kVar<\/td>\n<\/tr>\n<tr>\n<td>Tegangan<\/td>\n<td>230 V (+\/-20%)<\/td>\n<td>400 V (+\/-20%)<\/td>\n<td>500 V (+\/-201 TP3T)<\/td>\n<td>690 V (+\/-201 TP3T)<\/td>\n<\/tr>\n<tr>\n<td>Frekuensi<\/td>\n<td colspan=\"4\">50 Hz (+\/-51 TP3T)<\/td>\n<\/tr>\n<tr>\n<td>Fase<\/td>\n<td>1 Phase<\/td>\n<td colspan=\"3\">3 Fase<\/td>\n<\/tr>\n<tr>\n<td>Waktu respons<\/td>\n<td colspan=\"4\">&lt;10ms<\/td>\n<\/tr>\n<tr>\n<td>compensation factor<\/td>\n<td colspan=\"4\">&gt;95%<\/td>\n<\/tr>\n<tr>\n<td>Device efficiency<\/td>\n<td colspan=\"4\">&gt;97%<\/td>\n<\/tr>\n<tr>\n<td>Switching frequency<\/td>\n<td>32kHz<\/td>\n<td>16kHz<\/td>\n<td>12,8kHz<\/td>\n<td>12,8kHz<\/td>\n<\/tr>\n<tr>\n<td>Fungsi<\/td>\n<td colspan=\"4\">Kompensasi daya reaktif<\/td>\n<\/tr>\n<tr>\n<td>Jumlah modul<\/td>\n<td colspan=\"4\" width=\"488\">No limitations. One monitoring module can be<br \/>\nequipped with 32 actuator\/execution modules<\/td>\n<\/tr>\n<tr>\n<td>Communication<\/td>\n<td colspan=\"4\">Dual-channel RS485 (Support for wireless WiFi\/GPRS communication)<\/td>\n<\/tr>\n<tr>\n<td>Ketinggian di atas permukaan laut<\/td>\n<td colspan=\"4\">&lt;2000m<\/td>\n<\/tr>\n<tr>\n<td>Suhu<\/td>\n<td colspan=\"4\">-20 hingga +50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Kelembapan<\/td>\n<td colspan=\"4\">&lt;90%<\/td>\n<\/tr>\n<tr>\n<td>Tingkat Polusi<\/td>\n<td colspan=\"4\">Di Bawah Level 2<\/td>\n<\/tr>\n<tr>\n<td>Protections<\/td>\n<td colspan=\"4\" width=\"488\">Overload,Over\u00a0current,Over\u00a0voltage,Against supply network asymmetry,<br \/>\nThermal\/Over\u00a0temperature,Frequency fluctuations Short-circuit<\/td>\n<\/tr>\n<tr>\n<td>Kebisingan<\/td>\n<td>&lt;50dB<\/td>\n<td>&lt;60dB<\/td>\n<td colspan=\"2\">&lt;65dB<\/td>\n<\/tr>\n<tr>\n<td>Metode instalasi<\/td>\n<td colspan=\"4\">Pemasangan di Dinding<\/td>\n<\/tr>\n<tr>\n<td>Connection<\/td>\n<td colspan=\"4\">From the top (Wall-mounted)<\/td>\n<\/tr>\n<tr>\n<td>Derajat perlindungan<\/td>\n<td colspan=\"4\">IP20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong><b>Informasi Ukuran Produk<\/b><\/strong><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-962\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/4.SVG.webp\" alt=\"\" width=\"1500\" height=\"816\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"101\">Model<\/td>\n<td width=\"246\">Kapasitas (kvar)<\/td>\n<td width=\"71\">Tegangan (V)<\/td>\n<td width=\"113\">Ukuran (P\u00d7T\u00d7L) (mm)<\/td>\n<td width=\"133\">Pendinginan<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.23-2L-W<\/td>\n<td>20Kvar\/30Kvar\/35Kvar<\/td>\n<td>230V<\/td>\n<td>380x424x88<\/td>\n<td>Pendinginan Udara Paksa<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.23-2L-W<\/td>\n<td>50Kvar\/70Kvar\/100Kvar<\/td>\n<td>230V<\/td>\n<td>500x550x130<\/td>\n<td>Pendinginan Udara Paksa<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.4-4L-W<\/td>\n<td>10Kvar\/15Kvar\/20Kvar\/30Kvar\/35Kvar<\/td>\n<td>400V<\/td>\n<td>380x424x88<\/td>\n<td>Pendinginan Udara Paksa<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.4-4L-W<\/td>\n<td>50Kvar\/75Kvar\/100Kvar\/150Kvar<\/td>\n<td>400V<\/td>\n<td>500x550x130<\/td>\n<td>Pendinginan Udara Paksa<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.5-4L-W<\/td>\n<td>85Kvar<\/td>\n<td>500V<\/td>\n<td>500x550x130<\/td>\n<td>Pendinginan Udara Paksa<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.69-4L-W<\/td>\n<td>120Kvar<\/td>\n<td>690V<\/td>\n<td>500x550x130<\/td>\n<td>Pendinginan Udara Paksa<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Spesifikasi terbatas pada jenis standar; dimensi lain tersedia berdasarkan permintaan.<\/p>\n<h2><strong><b>Rack-mounted SVG<\/b><\/strong><\/h2>\n<p><strong>Spesifikasi Teknis<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"183\">KETIK<\/td>\n<td width=\"146\">Seri 230V<\/td>\n<td width=\"153\">Seri 400V<\/td>\n<td width=\"93\">Seri 500V<\/td>\n<td width=\"93\">Seri 690V<\/td>\n<\/tr>\n<tr>\n<td>Kapasitas<\/td>\n<td width=\"146\">20kVar\/30kVar\/35kVar\/<br \/>\n50kVar\/70kVar\/100kVar<\/td>\n<td width=\"153\">10kVar\/15kVar\/20kVar\/<br \/>\n30kVar\/35kVar\/50kVar\/<br \/>\n75kVar\/100kVar\/150kVar<\/td>\n<td>85kVar<\/td>\n<td>120kVar<\/td>\n<\/tr>\n<tr>\n<td>Tegangan<\/td>\n<td>230 V (+\/-20%)<\/td>\n<td>400 V (+\/-20%)<\/td>\n<td>500 V (+\/-201 TP3T)<\/td>\n<td>690 V (+\/-201 TP3T)<\/td>\n<\/tr>\n<tr>\n<td>Frekuensi<\/td>\n<td colspan=\"4\">50 Hz (+\/-51 TP3T)<\/td>\n<\/tr>\n<tr>\n<td>Fase<\/td>\n<td>1 Phase<\/td>\n<td colspan=\"3\">3 Fase<\/td>\n<\/tr>\n<tr>\n<td>Waktu respons<\/td>\n<td colspan=\"4\">&lt;10ms<\/td>\n<\/tr>\n<tr>\n<td>compensation factor<\/td>\n<td colspan=\"4\">&gt;95%<\/td>\n<\/tr>\n<tr>\n<td>Device efficiency<\/td>\n<td colspan=\"4\">&gt;97%<\/td>\n<\/tr>\n<tr>\n<td>Switching frequency<\/td>\n<td>32kHz<\/td>\n<td>16kHz<\/td>\n<td>12,8kHz<\/td>\n<td>12,8kHz<\/td>\n<\/tr>\n<tr>\n<td>Fungsi<\/td>\n<td colspan=\"4\">Kompensasi daya reaktif<\/td>\n<\/tr>\n<tr>\n<td>Jumlah modul<\/td>\n<td colspan=\"4\" width=\"487\">No limitations. One monitoring module can be<br \/>\nequipped with 32 actuator\/execution modules<\/td>\n<\/tr>\n<tr>\n<td>Communication<\/td>\n<td colspan=\"4\">Dual-channel RS485 (Support for wireless WiFi\/GPRS communication)<\/td>\n<\/tr>\n<tr>\n<td>Ketinggian di atas permukaan laut<\/td>\n<td colspan=\"4\">&lt;2000m<\/td>\n<\/tr>\n<tr>\n<td>Suhu<\/td>\n<td colspan=\"4\">-20 hingga +50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Kelembapan<\/td>\n<td colspan=\"4\">&lt;90%<\/td>\n<\/tr>\n<tr>\n<td>Tingkat Polusi<\/td>\n<td colspan=\"4\">Di Bawah Level 2<\/td>\n<\/tr>\n<tr>\n<td>Protections<\/td>\n<td colspan=\"4\" width=\"487\">Overload,Over current,Over voltage,Against supply network asymmetry,<br \/>\nThermal\/Over temperature,Frequency fluctuations Short-circuit<\/td>\n<\/tr>\n<tr>\n<td>Kebisingan<\/td>\n<td>&lt;50dB<\/td>\n<td>&lt;60dB<\/td>\n<td colspan=\"2\">&lt;65dB<\/td>\n<\/tr>\n<tr>\n<td>Metode instalasi<\/td>\n<td colspan=\"4\">Rack-mount<\/td>\n<\/tr>\n<tr>\n<td>Connection<\/td>\n<td colspan=\"4\">From the back (Rack)<\/td>\n<\/tr>\n<tr>\n<td>Derajat perlindungan<\/td>\n<td colspan=\"4\">IP20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><b>Informasi Ukuran Produk<\/b><\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1615\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators.webp\" alt=\"\" width=\"1500\" height=\"765\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators.webp 1500w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators-300x153.webp 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators-1024x522.webp 1024w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators-768x392.webp 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators-600x306.webp 600w\" sizes=\"auto, (max-width: 1500px) 100vw, 1500px\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"101\">Model<\/td>\n<td width=\"246\">Kapasitas (kvar)<\/td>\n<td width=\"71\">Tegangan (V)<\/td>\n<td width=\"113\">Ukuran (P\u00d7T\u00d7L) (mm)<\/td>\n<td width=\"133\">Pendinginan<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.23-2L-R<\/td>\n<td>20Kvar\/30Kvar\/35Kvar<\/td>\n<td>230V<\/td>\n<td>380x424x88<\/td>\n<td>Pendinginan Udara Paksa<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.23-2L-R<\/td>\n<td>50Kvar\/70Kvar\/100Kvar<\/td>\n<td>230V<\/td>\n<td>500x550x130<\/td>\n<td>Pendinginan Udara Paksa<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.4-4L-R<\/td>\n<td>10Kvar\/15Kvar\/20Kvar\/30Kvar\/35Kvar<\/td>\n<td>400V<\/td>\n<td>380x424x88<\/td>\n<td>Pendinginan Udara Paksa<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.4-4L-R<\/td>\n<td>50Kvar\/75Kvar\/100Kvar\/150Kvar<\/td>\n<td>400V<\/td>\n<td>500x550x130<\/td>\n<td>Pendinginan Udara Paksa<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.5-4L-R<\/td>\n<td>85Kvar<\/td>\n<td>500V<\/td>\n<td>500x550x130<\/td>\n<td>Pendinginan Udara Paksa<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.69-4L-R<\/td>\n<td>120Kvar<\/td>\n<td>690V<\/td>\n<td>500x550x130<\/td>\n<td>Pendinginan Udara Paksa<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Spesifikasi terbatas pada jenis standar; dimensi lain tersedia berdasarkan permintaan.<\/p>","protected":false},"excerpt":{"rendered":"<p>Our static reactive power compensators (SVG) provide an optimal solution for issues related to network stability, power factor, and reactive power demand in various industrial applications. The devices feature extremely fast operation, compact design, and exceptional cost efficiency, ensuring immediate response to disturbances in medium- and low-voltage power systems. By compensating reactive power, they significantly increase the lifespan of installations, enhance the reliability of production processes, improve system performance, and reduce transmission losses, all while meeting the most stringent energy quality standards.<\/p>","protected":false},"featured_media":1606,"template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[33,30],"product_tag":[],"class_list":["post-1689","product","type-product","status-publish","has-post-thumbnail","product_cat-power-quality-system","product_cat-products","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/cnbygele.com\/id\/wp-json\/wp\/v2\/product\/1689","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnbygele.com\/id\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnbygele.com\/id\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/id\/wp-json\/wp\/v2\/media\/1606"}],"wp:attachment":[{"href":"https:\/\/cnbygele.com\/id\/wp-json\/wp\/v2\/media?parent=1689"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnbygele.com\/id\/wp-json\/wp\/v2\/product_brand?post=1689"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnbygele.com\/id\/wp-json\/wp\/v2\/product_cat?post=1689"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnbygele.com\/id\/wp-json\/wp\/v2\/product_tag?post=1689"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}