{"id":1290,"date":"2026-04-29T10:02:18","date_gmt":"2026-04-29T02:02:18","guid":{"rendered":"https:\/\/w6pown520g.wpdns.site\/?post_type=product&#038;p=1290"},"modified":"2026-07-17T16:09:53","modified_gmt":"2026-07-17T08:09:53","slug":"ahf-active-harmonic-filter-harmonic-control","status":"publish","type":"product","link":"https:\/\/cnbygele.com\/pt\/product\/ahf-active-harmonic-filter-harmonic-control\/","title":{"rendered":"Filtro Ativo de Pot\u00eancia (APF) e Filtro Ativo de Harm\u00f3nicas (AHF)"},"content":{"rendered":"<h2>Descri\u00e7\u00e3o do Produto<\/h2>\n<p>O filtro ativo de pot\u00eancia AHF consegue monitorizar eficazmente as harm\u00f3nicas e extrair as respetivas correntes harm\u00f3nicas. O equipamento gera correntes harm\u00f3nicas inversas atrav\u00e9s de IGBT, suprimindo completamente as harm\u00f3nicas no ponto de liga\u00e7\u00e3o do equipamento e evitando perdas mais elevadas causadas pela circula\u00e7\u00e3o de correntes harm\u00f3nicas atrav\u00e9s de disjuntores ou transformadores. Simultaneamente, o equipamento tamb\u00e9m consegue gerir a pot\u00eancia reativa e os fen\u00f3menos de desequil\u00edbrio trif\u00e1sico, proporcionando uma verdadeira gest\u00e3o integrada e inteligente da qualidade da energia el\u00e9trica. O AHF consegue filtrar eficazmente as harm\u00f3nicas da 2.\u00aa \u00e0 50.\u00aa ordem.<\/p>\n<ul>\n<li>Melhorar a qualidade da alimenta\u00e7\u00e3o el\u00e9trica, aumentar a fiabilidade do funcionamento dos equipamentos e reduzir as perdas econ\u00f3micas causadas por avarias nos equipamentos<\/li>\n<li>Reduzir o aquecimento das linhas e o envelhecimento do isolamento, melhorando a seguran\u00e7a e a fiabilidade el\u00e9trica<\/li>\n<li>Reduzir a probabilidade de resson\u00e2ncia dos condensadores de compensa\u00e7\u00e3o e aumentar a seguran\u00e7a da instala\u00e7\u00e3o el\u00e9trica; cumprir os requisitos das normas nacionais<\/li>\n<li>Reduzir as interfer\u00eancias eletromagn\u00e9ticas causadas pelas harm\u00f3nicas e assegurar o funcionamento normal dos sistemas de comunica\u00e7\u00e3o<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-1609 size-full\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control.webp\" alt=\"\" width=\"1500\" height=\"872\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control.webp 1500w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-300x174.webp 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-1024x595.webp 1024w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-768x446.webp 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-600x349.webp 600w\" sizes=\"auto, (max-width: 1500px) 100vw, 1500px\" \/><\/p>\n<p><strong><b>Princ\u00edpio de funcionamento do AHF:<\/b><\/strong><\/p>\n<p>O AHF funciona atrav\u00e9s da monitoriza\u00e7\u00e3o cont\u00ednua e em tempo real da corrente da carga, utilizando transformadores de corrente externos (CT). O seu processador digital de sinal de alta velocidade (DSP) interno extrai as componentes harm\u00f3nicas e a corrente reativa da forma de onda detetada e, em seguida, gera uma corrente de compensa\u00e7\u00e3o precisa em oposi\u00e7\u00e3o de fase. Esta corrente de compensa\u00e7\u00e3o \u00e9 injetada novamente na linha de alimenta\u00e7\u00e3o el\u00e9trica atrav\u00e9s de um inversor com trans\u00edstores bipolares de porta isolada (IGBT), cancelando eficazmente as harm\u00f3nicas e corrigindo o fator de pot\u00eancia. Como resultado, o AHF garante que a rede el\u00e9trica fornece apenas a corrente fundamental, com um fator de pot\u00eancia pr\u00f3ximo da unidade, assegurando uma alimenta\u00e7\u00e3o el\u00e9trica limpa e est\u00e1vel.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-945\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.AHF-Active-Harmonic-Filter-Harmonic-Control.webp\" alt=\"\" width=\"1500\" height=\"1693\" \/><\/p>\n<h2><strong><b>AHF de Montagem na Parede<\/b><\/strong><\/h2>\n<p><strong>Especifica\u00e7\u00f5es T\u00e9cnicas<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"164\">TIPO<\/td>\n<td width=\"122\">S\u00e9rie 230 V<\/td>\n<td width=\"122\">S\u00e9rie 400 V<\/td>\n<td width=\"122\">S\u00e9rie 500 V<\/td>\n<td width=\"122\">S\u00e9rie 690 V<\/td>\n<\/tr>\n<tr>\n<td>Capacidade<\/td>\n<td width=\"122\">30 A\/50 A\/75 A<br \/>\n100 A\/150 A\/200 A<\/td>\n<td width=\"122\">30 A\/50 A\/75 A<br \/>\n100 A\/150 A\/200 A<\/td>\n<td width=\"122\">30 A\/50 A\/75 A<br \/>\n100 A\/150 A\/200 A<\/td>\n<td width=\"122\">30 A\/50 A\/75 A<br \/>\n100 A\/150 A<\/td>\n<\/tr>\n<tr>\n<td>Tens\u00e3o<\/td>\n<td>230 V (\u00b120%)<\/td>\n<td>400 V (\u00b120%)<\/td>\n<td>500 V (\u00b120%)<\/td>\n<td>690 V (\u00b120%)<\/td>\n<\/tr>\n<tr>\n<td>Frequ\u00eancia<\/td>\n<td colspan=\"4\">50 Hz (\u00b15%)<\/td>\n<\/tr>\n<tr>\n<td>Fase<\/td>\n<td colspan=\"4\">3 fases<\/td>\n<\/tr>\n<tr>\n<td>Tempo de resposta<\/td>\n<td colspan=\"4\">&lt;5 ms<\/td>\n<\/tr>\n<tr>\n<td>Transformador de corrente<\/td>\n<td colspan=\"4\">150:5~10 000:5<\/td>\n<\/tr>\n<tr>\n<td>Efici\u00eancia e perdas<\/td>\n<td colspan=\"4\">Efici\u00eancia \u226597% (3 fases), perda \u226415 W\/A<\/td>\n<\/tr>\n<tr>\n<td>Fun\u00e7\u00e3o<\/td>\n<td colspan=\"4\">Elimina\u00e7\u00e3o de harm\u00f3nicos<\/td>\n<\/tr>\n<tr>\n<td>N\u00famero de m\u00f3dulos<\/td>\n<td colspan=\"4\" width=\"491\">Sem limita\u00e7\u00f5es. Um m\u00f3dulo de monitoriza\u00e7\u00e3o pode ser equipado com 32 m\u00f3dulos de atua\u00e7\u00e3o\/execu\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td>Protocolo de comunica\u00e7\u00e3o<\/td>\n<td colspan=\"4\">Modbus, TCP\/IP, CAN<\/td>\n<\/tr>\n<tr>\n<td>Altitude acima do n\u00edvel do mar<\/td>\n<td colspan=\"4\">&lt;2000m<\/td>\n<\/tr>\n<tr>\n<td>Temperatura<\/td>\n<td colspan=\"4\">-20~+50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Humidade<\/td>\n<td colspan=\"4\">&lt;90%<\/td>\n<\/tr>\n<tr>\n<td>Grau de polui\u00e7\u00e3o<\/td>\n<td colspan=\"4\">Inferior ao n\u00edvel 2<\/td>\n<\/tr>\n<tr>\n<td>Modo de compensa\u00e7\u00e3o<\/td>\n<td colspan=\"4\" width=\"491\">Supress\u00e3o de harm\u00f3nicas\/compensa\u00e7\u00e3o de pot\u00eancia reativa\/compensa\u00e7\u00e3o de desequil\u00edbrio,<\/p>\n<p>11 modos em qualquer combina\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td>Ru\u00eddo<\/td>\n<td>&lt;50 dB<\/td>\n<td>&lt;60 dB<\/td>\n<td colspan=\"2\">&lt;65 dB<\/td>\n<\/tr>\n<tr>\n<td>M\u00e9todo de instala\u00e7\u00e3o<\/td>\n<td colspan=\"4\">Montagem na parede<\/td>\n<\/tr>\n<tr>\n<td>Conformidade com as normas<\/td>\n<td colspan=\"4\">IEEE519\u3001IEC6100-3-6\u3001ER G5\/4\u3001CE, Conformidade EMC: EN 61000-6-4 Classe A<\/td>\n<\/tr>\n<tr>\n<td>Grau de prote\u00e7\u00e3o<\/td>\n<td colspan=\"4\">IP20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><b>Informa\u00e7\u00f5es sobre as dimens\u00f5es do produto<\/b><\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-947\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/4.AHF-Active-Harmonic-Filter-Harmonic-Control.webp\" alt=\"\" width=\"1500\" height=\"778\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"112\">Modelo<\/td>\n<td width=\"213\">Capacidade (kvar)<\/td>\n<td width=\"79\">Tens\u00e3o (V)<\/td>\n<td width=\"117\">Dimens\u00f5es (L*A*P) (mm)<\/td>\n<td width=\"140\">Arrefecimento<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.23-3L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>230 V<\/td>\n<td>480x570x175<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.23-3L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>230 V<\/td>\n<td>480x570x175<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.4-4L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>400 V<\/td>\n<td>480x570x175<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.4-4L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>400 V<\/td>\n<td>480x570x175<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.5-4L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>500 V<\/td>\n<td>480x570x175<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.69-4L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A<\/td>\n<td>690 V<\/td>\n<td>480x570x175<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>A especifica\u00e7\u00e3o limita-se aos modelos padr\u00e3o; est\u00e3o dispon\u00edveis outras dimens\u00f5es mediante pedido.<\/p>\n<h2><strong><b>AHF para montagem em bastidor<\/b><\/strong><\/h2>\n<p><strong>Especifica\u00e7\u00f5es T\u00e9cnicas<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"165\">TIPO<\/td>\n<td width=\"123\">S\u00e9rie 230 V<\/td>\n<td width=\"123\">S\u00e9rie 400 V<\/td>\n<td width=\"123\">S\u00e9rie 500 V<\/td>\n<td width=\"123\">S\u00e9rie 690 V<\/td>\n<\/tr>\n<tr>\n<td>Capacidade<\/td>\n<td width=\"123\">30 A\/50 A\/75 A<br \/>\n100 A\/150 A\/200 A<\/td>\n<td width=\"123\">30 A\/50 A\/75 A<br \/>\n100 A\/150 A\/200 A<\/td>\n<td width=\"123\">30 A\/50 A\/75 A<br \/>\n100 A\/150 A\/200 A<\/td>\n<td width=\"123\">30 A\/50 A\/75 A<br \/>\n100 A\/150 A<\/td>\n<\/tr>\n<tr>\n<td>Tens\u00e3o<\/td>\n<td>230 V (\u00b120%)<\/td>\n<td>400 V (\u00b120%)<\/td>\n<td>500 V (\u00b120%)<\/td>\n<td>690 V (\u00b120%)<\/td>\n<\/tr>\n<tr>\n<td>Frequ\u00eancia<\/td>\n<td colspan=\"4\">50 Hz (\u00b15%)<\/td>\n<\/tr>\n<tr>\n<td>Fase<\/td>\n<td colspan=\"4\">3 fases<\/td>\n<\/tr>\n<tr>\n<td>Tempo de resposta<\/td>\n<td colspan=\"4\">&lt;5 ms<\/td>\n<\/tr>\n<tr>\n<td>Transformador de corrente<\/td>\n<td colspan=\"4\">150:5~10 000:5<\/td>\n<\/tr>\n<tr>\n<td>Efici\u00eancia e perdas<\/td>\n<td colspan=\"4\">Efici\u00eancia \u226597% (3 fases), perda \u226415 W\/A<\/td>\n<\/tr>\n<tr>\n<td>Fun\u00e7\u00e3o<\/td>\n<td colspan=\"4\">Elimina\u00e7\u00e3o de harm\u00f3nicos<\/td>\n<\/tr>\n<tr>\n<td>N\u00famero de m\u00f3dulos<\/td>\n<td colspan=\"4\" width=\"493\">Sem limita\u00e7\u00f5es. Um m\u00f3dulo de monitoriza\u00e7\u00e3o pode ser equipado com 32 m\u00f3dulos de atua\u00e7\u00e3o\/execu\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td>Protocolo de comunica\u00e7\u00e3o<\/td>\n<td colspan=\"4\">Modbus, TCP\/IP, CAN<\/td>\n<\/tr>\n<tr>\n<td>Altitude acima do n\u00edvel do mar<\/td>\n<td colspan=\"4\">&lt;2000m<\/td>\n<\/tr>\n<tr>\n<td>Temperatura<\/td>\n<td colspan=\"4\">-20~+50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Humidade<\/td>\n<td colspan=\"4\">&lt;90%<\/td>\n<\/tr>\n<tr>\n<td>Grau de polui\u00e7\u00e3o<\/td>\n<td colspan=\"4\">Inferior ao n\u00edvel 2<\/td>\n<\/tr>\n<tr>\n<td>Modo de compensa\u00e7\u00e3o<\/td>\n<td colspan=\"4\" width=\"493\">Supress\u00e3o de harm\u00f3nicas\/compensa\u00e7\u00e3o de pot\u00eancia reativa\/compensa\u00e7\u00e3o de desequil\u00edbrios, com 11 modos combin\u00e1veis livremente<\/td>\n<\/tr>\n<tr>\n<td>Ru\u00eddo<\/td>\n<td>&lt;50 dB<\/td>\n<td>&lt;60 dB<\/td>\n<td colspan=\"2\">&lt;65 dB<\/td>\n<\/tr>\n<tr>\n<td>M\u00e9todo de instala\u00e7\u00e3o<\/td>\n<td colspan=\"4\">Montagem em bastidor<\/td>\n<\/tr>\n<tr>\n<td>Conformidade com as normas<\/td>\n<td colspan=\"4\">IEEE519\u3001IEC6100-3-6\u3001ER G5\/4\u3001CE, Conformidade EMC: EN 61000-6-4 Classe A<\/td>\n<\/tr>\n<tr>\n<td>Grau de prote\u00e7\u00e3o<\/td>\n<td colspan=\"4\">IP20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong><b>Informa\u00e7\u00f5es sobre as dimens\u00f5es do produto<\/b><\/strong><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1610\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.1-AHF-Active-Harmonic-Filter-Harmonic-Control.webp\" alt=\"\" width=\"1500\" height=\"765\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.1-AHF-Active-Harmonic-Filter-Harmonic-Control.webp 1500w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.1-AHF-Active-Harmonic-Filter-Harmonic-Control-300x153.webp 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.1-AHF-Active-Harmonic-Filter-Harmonic-Control-1024x522.webp 1024w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.1-AHF-Active-Harmonic-Filter-Harmonic-Control-768x392.webp 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.1-AHF-Active-Harmonic-Filter-Harmonic-Control-600x306.webp 600w\" sizes=\"auto, (max-width: 1500px) 100vw, 1500px\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"112\">Modelo<\/td>\n<td width=\"208\">Capacidade (kvar)<\/td>\n<td width=\"81\">Tens\u00e3o (V)<\/td>\n<td width=\"120\">Dimens\u00f5es (L*A*P) (mm)<\/td>\n<td width=\"143\">Arrefecimento<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.23-3L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>230 V<\/td>\n<td>480x570x175<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.23-3L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>230 V<\/td>\n<td>480x570x175<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.4-4L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>400 V<\/td>\n<td>480x570x175<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.4-4L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>400 V<\/td>\n<td>480x570x175<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.5-4L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>500 V<\/td>\n<td>480x570x175<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.69-4L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A<\/td>\n<td>690 V<\/td>\n<td>480x570x175<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>A especifica\u00e7\u00e3o limita-se aos modelos padr\u00e3o; est\u00e3o dispon\u00edveis outras dimens\u00f5es mediante pedido.<\/p>\n<p><!-- CNBYG-HUB-RESOURCES-START --><\/p>\n<section>\n<h2>Centro de apoio \u00e0 aplica\u00e7\u00e3o e sele\u00e7\u00e3o de AHF\/APF<\/h2>\n<p>O Filtro Ativo de Harm\u00f3nicas (AHF) da CNBYG, tamb\u00e9m designado por Filtro Ativo de Pot\u00eancia (APF), \u00e9 uma solu\u00e7\u00e3o da gama de produtos destinada a projetos em que a corrente harm\u00f3nica medida, a procura de pot\u00eancia reativa ou o desequil\u00edbrio trif\u00e1sico necessitam de uma avalia\u00e7\u00e3o t\u00e9cnica. Antes de selecionar um modelo ou uma pot\u00eancia nominal, confirme o ponto de liga\u00e7\u00e3o, o perfil de carga, o espectro harm\u00f3nico, a topologia da instala\u00e7\u00e3o e os crit\u00e9rios de aceita\u00e7\u00e3o exigidos.<\/p>\n<p><a href=\"\/pt\/contact-us\/\">Partilhe os dados do projeto AHF\/APF<\/a><\/p>\n<\/section>\n<section>\n<h2>Quando iniciar uma avalia\u00e7\u00e3o AHF\/APF<\/h2>\n<div>\n<article>\n<h3><a href=\"https:\/\/cnbygele.com\/pt\/blog\/vfd-harmonics-industrial-plants-apf-selection\/\">Cargas industriais com elevada utiliza\u00e7\u00e3o de variadores de frequ\u00eancia (VFD)<\/a><\/h3>\n<p>Utilize os dados de carga medidos e os perfis de funcionamento para definir o problema antes de dimensionar o equipamento.<\/p>\n<\/article>\n<article>\n<h3><a href=\"https:\/\/cnbygele.com\/pt\/blog\/data-center-neutral-harmonics-apf-selection\/\">Quest\u00f5es relacionadas com harm\u00f3nicas e corrente no neutro em centros de dados<\/a><\/h3>\n<p>Analise a carga no neutro e o ponto de medi\u00e7\u00e3o relevante como parte do projeto.<\/p>\n<\/article>\n<article>\n<h3><a href=\"https:\/\/cnbygele.com\/pt\/blog\/ieee-519-harmonic-limits-apf-sizing\/\">Planeamento de projetos segundo a norma IEEE 519<\/a><\/h3>\n<p>O artigo explica os dados necess\u00e1rios ao planeamento, mas n\u00e3o substitui um estudo de conformidade.<\/p>\n<\/article>\n<article>\n<h3><a href=\"\/pt\/power-quality-system\/\">Requisitos combinados de APF e SVG<\/a><\/h3>\n<p>Utilize o centro de apoio ao sistema quando as medi\u00e7\u00f5es identificarem objetivos distintos para as harm\u00f3nicas e a pot\u00eancia reativa.<\/p>\n<\/article>\n<\/div>\n<\/section>\n<section>\n<h2>Par\u00e2metros de sele\u00e7\u00e3o AHF\/APF<\/h2>\n<ul>\n<li>Diagrama unifilar, tens\u00e3o de servi\u00e7o, frequ\u00eancia, dados do transformador e ponto de instala\u00e7\u00e3o previsto<\/li>\n<li>Medi\u00e7\u00f5es representativas de corrente e tens\u00e3o, incluindo o espectro harm\u00f3nico e o modo de funcionamento<\/li>\n<li>Invent\u00e1rio de cargas n\u00e3o lineares, varia\u00e7\u00e3o da carga, condensadores\/reatores existentes e configura\u00e7\u00e3o das prote\u00e7\u00f5es<\/li>\n<li>Espa\u00e7o dispon\u00edvel, arrefecimento, encaminhamento dos cabos, comunica\u00e7\u00f5es e requisitos aplic\u00e1veis de aceita\u00e7\u00e3o do projeto<\/li>\n<\/ul>\n<p>Os dados do produto devem ser avaliados em fun\u00e7\u00e3o destes par\u00e2metros; nenhuma p\u00e1gina gen\u00e9rica pode garantir um determinado resultado em termos de harm\u00f3nicas ou de conformidade.<\/p>\n<\/section>\n<section>\n<h2>Recursos t\u00e9cnicos selecionados<\/h2>\n<p>Utilize estes artigos para enquadrar a quest\u00e3o t\u00e9cnica antes de solicitar uma recomenda\u00e7\u00e3o para o projeto.<\/p>\n<ul>\n<li><a href=\"https:\/\/cnbygele.com\/pt\/blog\/active-harmonic-filter-ahf-selection-guide\/\">Guia de sele\u00e7\u00e3o de filtros ativos de harm\u00f3nicas (AHF)<\/a><\/li>\n<li><a href=\"https:\/\/cnbygele.com\/pt\/blog\/vfd-harmonics-industrial-plants-apf-selection\/\">Harm\u00f3nicas de variadores de frequ\u00eancia (VFD) em instala\u00e7\u00f5es industriais: sele\u00e7\u00e3o de filtros ativos de pot\u00eancia (APF)<\/a><\/li>\n<li><a href=\"https:\/\/cnbygele.com\/pt\/blog\/ieee-519-harmonic-limits-apf-sizing\/\">Limites de harm\u00f3nicas da norma IEEE 519 e dimensionamento de filtros ativos de pot\u00eancia (APF)<\/a><\/li>\n<li><a href=\"https:\/\/cnbygele.com\/pt\/blog\/data-center-neutral-harmonics-apf-selection\/\">Harm\u00f3nicas no neutro de centros de dados e sele\u00e7\u00e3o de filtros ativos de pot\u00eancia (APF)<\/a><\/li>\n<li><a href=\"https:\/\/cnbygele.com\/pt\/blog\/welding-robot-harmonic-profile-mitigation\/\">Perfil harm\u00f3nico de rob\u00f4s de soldadura e medidas de mitiga\u00e7\u00e3o<\/a><\/li>\n<li><a href=\"https:\/\/cnbygele.com\/pt\/blog\/apf-svg-automobile-manufacturing-harmonic-guide\/\">APF e SVG para fabrica\u00e7\u00e3o de autom\u00f3veis<\/a><\/li>\n<\/ul>\n<\/section>\n<section>\n<h2>P\u00e1ginas de solu\u00e7\u00e3o relacionadas<\/h2>\n<div>\n<article>\n<h3><a href=\"https:\/\/cnbygele.com\/pt\/solutions\/automobile-manufacturing\/\">Fabrico de Autom\u00f3veis<\/a><\/h3>\n<p>Controladores de velocidade vari\u00e1vel, equipamentos de soldadura e cargas de automa\u00e7\u00e3o requerem medi\u00e7\u00e3o antes de selecionar um caminho de mitiga\u00e7\u00e3o.<\/p>\n<\/article>\n<article>\n<h3><a href=\"https:\/\/cnbygele.com\/pt\/solutions\/data-center\/\">Centro de Dados<\/a><\/h3>\n<p>Trate as cargas harm\u00f4nicas, corrente neutra e requisitos de continuidade como uma revis\u00e3o de projeto coordenada.<\/p>\n<\/article>\n<article>\n<h3><a href=\"https:\/\/cnbygele.com\/pt\/solutions\/photovoltaic-charging-station\/\">Esta\u00e7\u00e3o Fotovoltaica &amp; de Carregamento<\/a><\/h3>\n<p>Inversores e cargas de carregamento podem alterar as condi\u00e7\u00f5es de opera\u00e7\u00e3o; revise os dados no ponto de conex\u00e3o relevante.<\/p>\n<\/article>\n<article>\n<h3><a href=\"https:\/\/cnbygele.com\/pt\/solutions\/marine-shipbuilding\/\">Marinha &amp; Constru\u00e7\u00e3o Naval<\/a><\/h3>\n<p>Soldadura, interfaces de energia de costa e restri\u00e7\u00f5es operacionais mar\u00edtimas precisam de uma avalia\u00e7\u00e3o espec\u00edfica do projeto.<\/p>\n<\/article>\n<\/div>\n<\/section>\n<section>\n<h2>Perguntas frequentes<\/h2>\n<h3>AHF e APF s\u00e3o a mesma categoria de produto?<\/h3>\n<p>Estes termos s\u00e3o comumente usados para equipamentos de filtragem ativa. Confirme a fun\u00e7\u00e3o real do produto e a configura\u00e7\u00e3o do projeto na documenta\u00e7\u00e3o t\u00e9cnica e revis\u00e3o da aplica\u00e7\u00e3o.<\/p>\n<h3>Um AHF\/APF pode ser dimensionado a partir da carga total conectada?<\/h3>\n<p>N\u00e3o. O dimensionamento necessita de corrente harm\u00f4nica medida e condi\u00e7\u00f5es de opera\u00e7\u00e3o espec\u00edficas do projeto, al\u00e9m do invent\u00e1rio de carga.<\/p>\n<\/section>\n<p><!-- CNBYG-HUB-RESOURCES-END --><\/p>","protected":false},"excerpt":{"rendered":"<p>Os filtros ativos de harm\u00f3nicas AHF melhoram a qualidade da energia el\u00e9trica e a fiabilidade dos equipamentos atrav\u00e9s do controlo das harm\u00f3nicas, reduzindo as perdas econ\u00f3micas causadas por avarias nos equipamentos. Reduzem o aquecimento das linhas e o envelhecimento do isolamento, aumentando a seguran\u00e7a e a fiabilidade el\u00e9trica. Al\u00e9m disso, reduzem a probabilidade de resson\u00e2ncia dos condensadores de compensa\u00e7\u00e3o, garantindo a seguran\u00e7a da instala\u00e7\u00e3o el\u00e9trica e a conformidade com as normas nacionais. O equipamento reduz as interfer\u00eancias eletromagn\u00e9ticas causadas pelas harm\u00f3nicas, assegurando o funcionamento normal dos sistemas de comunica\u00e7\u00e3o.<\/p>","protected":false},"featured_media":1607,"template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[33,30],"product_tag":[],"class_list":["post-1290","product","type-product","status-publish","has-post-thumbnail","product_cat-power-quality-system","product_cat-products","first","instock","downloadable","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/product\/1290","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/media\/1607"}],"wp:attachment":[{"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/media?parent=1290"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/product_brand?post=1290"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/product_cat?post=1290"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/product_tag?post=1290"}],"curies":[{"name":"bem jogado","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}