{"id":1291,"date":"2026-04-29T10:02:18","date_gmt":"2026-04-29T02:02:18","guid":{"rendered":"https:\/\/w6pown520g.wpdns.site\/?post_type=product&#038;p=1291"},"modified":"2026-07-17T16:09:58","modified_gmt":"2026-07-17T08:09:58","slug":"svg-static-var-generators","status":"publish","type":"product","link":"https:\/\/cnbygele.com\/pt\/product\/svg-static-var-generators\/","title":{"rendered":"Gerador Est\u00e1tico de Energia Reativa (SVG) e Gerador Est\u00e1tico Avan\u00e7ado de Energia Reativa (ASVG)"},"content":{"rendered":"<h2>Descri\u00e7\u00e3o do Produto<\/h2>\n<p>O consumo de pot\u00eancia reativa implica custos adicionais cobrados pelos operadores de rede. Por este motivo, a utiliza\u00e7\u00e3o de um compensador SVG permite reduzir eficazmente a fatura de eletricidade, eliminando completamente os custos associados ao consumo de pot\u00eancia reativa.<\/p>\n<ul>\n<li>Compensa\u00e7\u00e3o imediata e precisa da pot\u00eancia reativa<\/li>\n<li>Supress\u00e3o ativa de harm\u00f3nicas<\/li>\n<li>Adapta\u00e7\u00e3o din\u00e2mica \u00e0s condi\u00e7\u00f5es de funcionamento vari\u00e1veis<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1609\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control.webp\" alt=\"\" width=\"1500\" height=\"872\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control.webp 1500w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-300x174.webp 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-1024x595.webp 1024w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-768x446.webp 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-600x349.webp 600w\" sizes=\"auto, (max-width: 1500px) 100vw, 1500px\" \/><\/p>\n<p><strong><b>Princ\u00edpio de funcionamento do SVG<\/b><\/strong><\/p>\n<p>O princ\u00edpio de funcionamento do compensador SVG baseia-se na monitoriza\u00e7\u00e3o cont\u00ednua das formas de onda da corrente e da tens\u00e3o na rede.<\/p>\n<p>Quando o sistema deteta desvios de fase causados pela natureza da carga, gera imediatamente uma corrente de compensa\u00e7\u00e3o com caracter\u00edsticas opostas. Gra\u00e7as \u00e0 utiliza\u00e7\u00e3o de m\u00f3dulos IGBT alem\u00e3es da Infineon e ao controlo PWM de precis\u00e3o, o equipamento corrige o fator de pot\u00eancia em tempo real, compensando tanto a pot\u00eancia reativa indutiva como a capacitiva. Este modo de funcionamento ativo assegura a manuten\u00e7\u00e3o de par\u00e2metros ideais de alimenta\u00e7\u00e3o el\u00e9trica, independentemente das flutua\u00e7\u00f5es da carga, garantindo uma fiabilidade excecional e a m\u00e1xima precis\u00e3o de compensa\u00e7\u00e3o.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1613\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1.webp\" alt=\"\" width=\"2480\" height=\"2339\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1.webp 2480w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-300x283.webp 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-1024x966.webp 1024w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-768x724.webp 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-1536x1449.webp 1536w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-2048x1932.webp 2048w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-600x566.webp 600w\" sizes=\"auto, (max-width: 2480px) 100vw, 2480px\" \/><\/p>\n<h2><strong><b>SVG de montagem na parede<\/b><\/strong><\/h2>\n<p><strong>Especifica\u00e7\u00f5es T\u00e9cnicas<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"174\">TIPO<\/td>\n<td width=\"149\">S\u00e9rie 230 V<\/td>\n<td width=\"155\">S\u00e9rie 400 V<\/td>\n<td width=\"91\">S\u00e9rie 500 V<\/td>\n<td width=\"91\">S\u00e9rie 690 V<\/td>\n<\/tr>\n<tr>\n<td>Capacidade<\/td>\n<td width=\"149\">20kVar\/30kVar\/35kVar\/<br \/>\n50kVar\/70kVar\/100kVar<\/td>\n<td width=\"155\">10kVar\/15kVar\/20kVar\/<br \/>\n30kVar\/35kVar\/50kVar\/<br \/>\n75kVar\/100kVar\/150kVar<\/td>\n<td>85 kVar<\/td>\n<td>120 kVar<\/td>\n<\/tr>\n<tr>\n<td>Tens\u00e3o<\/td>\n<td>230 V (\u00b120%)<\/td>\n<td>400 V (\u00b120%)<\/td>\n<td>500 V (\u00b120%)<\/td>\n<td>690 V (\u00b120%)<\/td>\n<\/tr>\n<tr>\n<td>Frequ\u00eancia<\/td>\n<td colspan=\"4\">50 Hz (\u00b15%)<\/td>\n<\/tr>\n<tr>\n<td>Fase<\/td>\n<td>Monof\u00e1sico<\/td>\n<td colspan=\"3\">3 fases<\/td>\n<\/tr>\n<tr>\n<td>Tempo de resposta<\/td>\n<td colspan=\"4\">&lt;10 ms<\/td>\n<\/tr>\n<tr>\n<td>Fator de compensa\u00e7\u00e3o<\/td>\n<td colspan=\"4\">&gt;95%<\/td>\n<\/tr>\n<tr>\n<td>Efici\u00eancia do equipamento<\/td>\n<td colspan=\"4\">&gt;97%<\/td>\n<\/tr>\n<tr>\n<td>Frequ\u00eancia de comuta\u00e7\u00e3o<\/td>\n<td>32 kHz<\/td>\n<td>16 kHz<\/td>\n<td>12,8 kHz<\/td>\n<td>12,8 kHz<\/td>\n<\/tr>\n<tr>\n<td>Fun\u00e7\u00e3o<\/td>\n<td colspan=\"4\">Compensa\u00e7\u00e3o de pot\u00eancia reativa<\/td>\n<\/tr>\n<tr>\n<td>N\u00famero de m\u00f3dulos<\/td>\n<td colspan=\"4\" width=\"488\">Sem limita\u00e7\u00f5es. Um m\u00f3dulo de monitoriza\u00e7\u00e3o pode ser<br \/>\nequipado com 32 m\u00f3dulos de acionamento\/execu\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td>Comunica\u00e7\u00e3o<\/td>\n<td colspan=\"4\">RS485 de canal duplo (suporta comunica\u00e7\u00e3o sem fios Wi-Fi\/GPRS)<\/td>\n<\/tr>\n<tr>\n<td>Altitude acima do n\u00edvel do mar<\/td>\n<td colspan=\"4\">&lt;2000m<\/td>\n<\/tr>\n<tr>\n<td>Temperatura<\/td>\n<td colspan=\"4\">-20~+50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Humidade<\/td>\n<td colspan=\"4\">&lt;90%<\/td>\n<\/tr>\n<tr>\n<td>Grau de polui\u00e7\u00e3o<\/td>\n<td colspan=\"4\">Inferior ao n\u00edvel 2<\/td>\n<\/tr>\n<tr>\n<td>Prote\u00e7\u00f5es<\/td>\n<td colspan=\"4\" width=\"488\">Sobrecarga, sobreintensidade, sobretens\u00e3o, contra assimetria da rede de alimenta\u00e7\u00e3o,<br \/>\nProte\u00e7\u00e3o t\u00e9rmica\/sobreaquecimento, flutua\u00e7\u00f5es de frequ\u00eancia, curto-circuito<\/td>\n<\/tr>\n<tr>\n<td>Ru\u00eddo<\/td>\n<td>&lt;50 dB<\/td>\n<td>&lt;60 dB<\/td>\n<td colspan=\"2\">&lt;65 dB<\/td>\n<\/tr>\n<tr>\n<td>M\u00e9todo de instala\u00e7\u00e3o<\/td>\n<td colspan=\"4\">Montagem na parede<\/td>\n<\/tr>\n<tr>\n<td>Liga\u00e7\u00e3o<\/td>\n<td colspan=\"4\">Pela parte superior (montagem na parede)<\/td>\n<\/tr>\n<tr>\n<td>Grau de prote\u00e7\u00e3o<\/td>\n<td colspan=\"4\">IP20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong><b>Informa\u00e7\u00f5es sobre as dimens\u00f5es do produto<\/b><\/strong><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-962\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/4.SVG.webp\" alt=\"\" width=\"1500\" height=\"816\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"101\">Modelo<\/td>\n<td width=\"246\">Capacidade (kvar)<\/td>\n<td width=\"71\">Tens\u00e3o (V)<\/td>\n<td width=\"113\">Dimens\u00f5es (L*A*P) (mm)<\/td>\n<td width=\"133\">Arrefecimento<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.23-2L-W<\/td>\n<td>20Kvar\/30Kvar\/35Kvar<\/td>\n<td>230 V<\/td>\n<td>380x424x88<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.23-2L-W<\/td>\n<td>50Kvar\/70Kvar\/100Kvar<\/td>\n<td>230 V<\/td>\n<td>500x550x130<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.4-4L-W<\/td>\n<td>10Kvar\/15Kvar\/20Kvar\/30Kvar\/35Kvar<\/td>\n<td>400 V<\/td>\n<td>380x424x88<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.4-4L-W<\/td>\n<td>50Kvar\/75Kvar\/100Kvar\/150Kvar<\/td>\n<td>400 V<\/td>\n<td>500x550x130<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.5-4L-W<\/td>\n<td>85 kVAr<\/td>\n<td>500 V<\/td>\n<td>500x550x130<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.69-4L-W<\/td>\n<td>120 kVAr<\/td>\n<td>690 V<\/td>\n<td>500x550x130<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>A especifica\u00e7\u00e3o limita-se aos modelos padr\u00e3o; est\u00e3o dispon\u00edveis outras dimens\u00f5es mediante pedido.<\/p>\n<h2><strong><b>SVG SVG para montagem em bastidor<\/b><\/strong><\/h2>\n<p><strong>Especifica\u00e7\u00f5es T\u00e9cnicas<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"183\">TIPO<\/td>\n<td width=\"146\">S\u00e9rie 230 V<\/td>\n<td width=\"153\">S\u00e9rie 400 V<\/td>\n<td width=\"93\">S\u00e9rie 500 V<\/td>\n<td width=\"93\">S\u00e9rie 690 V<\/td>\n<\/tr>\n<tr>\n<td>Capacidade<\/td>\n<td width=\"146\">20kVar\/30kVar\/35kVar\/<br \/>\n50kVar\/70kVar\/100kVar<\/td>\n<td width=\"153\">10kVar\/15kVar\/20kVar\/<br \/>\n30kVar\/35kVar\/50kVar\/<br \/>\n75kVar\/100kVar\/150kVar<\/td>\n<td>85 kVar<\/td>\n<td>120 kVar<\/td>\n<\/tr>\n<tr>\n<td>Tens\u00e3o<\/td>\n<td>230 V (\u00b120%)<\/td>\n<td>400 V (\u00b120%)<\/td>\n<td>500 V (\u00b120%)<\/td>\n<td>690 V (\u00b120%)<\/td>\n<\/tr>\n<tr>\n<td>Frequ\u00eancia<\/td>\n<td colspan=\"4\">50 Hz (\u00b15%)<\/td>\n<\/tr>\n<tr>\n<td>Fase<\/td>\n<td>Monof\u00e1sico<\/td>\n<td colspan=\"3\">3 fases<\/td>\n<\/tr>\n<tr>\n<td>Tempo de resposta<\/td>\n<td colspan=\"4\">&lt;10 ms<\/td>\n<\/tr>\n<tr>\n<td>Fator de compensa\u00e7\u00e3o<\/td>\n<td colspan=\"4\">&gt;95%<\/td>\n<\/tr>\n<tr>\n<td>Efici\u00eancia do equipamento<\/td>\n<td colspan=\"4\">&gt;97%<\/td>\n<\/tr>\n<tr>\n<td>Frequ\u00eancia de comuta\u00e7\u00e3o<\/td>\n<td>32 kHz<\/td>\n<td>16 kHz<\/td>\n<td>12,8 kHz<\/td>\n<td>12,8 kHz<\/td>\n<\/tr>\n<tr>\n<td>Fun\u00e7\u00e3o<\/td>\n<td colspan=\"4\">Compensa\u00e7\u00e3o de pot\u00eancia reativa<\/td>\n<\/tr>\n<tr>\n<td>N\u00famero de m\u00f3dulos<\/td>\n<td colspan=\"4\" width=\"487\">Sem limita\u00e7\u00f5es. Um m\u00f3dulo de monitoriza\u00e7\u00e3o pode ser<br \/>\nequipado com 32 m\u00f3dulos de acionamento\/execu\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td>Comunica\u00e7\u00e3o<\/td>\n<td colspan=\"4\">RS485 de canal duplo (suporta comunica\u00e7\u00e3o sem fios Wi-Fi\/GPRS)<\/td>\n<\/tr>\n<tr>\n<td>Altitude acima do n\u00edvel do mar<\/td>\n<td colspan=\"4\">&lt;2000m<\/td>\n<\/tr>\n<tr>\n<td>Temperatura<\/td>\n<td colspan=\"4\">-20~+50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Humidade<\/td>\n<td colspan=\"4\">&lt;90%<\/td>\n<\/tr>\n<tr>\n<td>Grau de polui\u00e7\u00e3o<\/td>\n<td colspan=\"4\">Inferior ao n\u00edvel 2<\/td>\n<\/tr>\n<tr>\n<td>Prote\u00e7\u00f5es<\/td>\n<td colspan=\"4\" width=\"487\">Sobrecarga, sobreintensidade, sobretens\u00e3o, contra assimetria da rede de alimenta\u00e7\u00e3o,<br \/>\nProte\u00e7\u00e3o t\u00e9rmica\/sobreaquecimento, flutua\u00e7\u00f5es de frequ\u00eancia, curto-circuito<\/td>\n<\/tr>\n<tr>\n<td>Ru\u00eddo<\/td>\n<td>&lt;50 dB<\/td>\n<td>&lt;60 dB<\/td>\n<td colspan=\"2\">&lt;65 dB<\/td>\n<\/tr>\n<tr>\n<td>M\u00e9todo de instala\u00e7\u00e3o<\/td>\n<td colspan=\"4\">Montagem em bastidor<\/td>\n<\/tr>\n<tr>\n<td>Liga\u00e7\u00e3o<\/td>\n<td colspan=\"4\">Vista traseira (bastidor)<\/td>\n<\/tr>\n<tr>\n<td>Grau de prote\u00e7\u00e3o<\/td>\n<td colspan=\"4\">IP20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><b>Informa\u00e7\u00f5es sobre as dimens\u00f5es do produto<\/b><\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1615\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators.webp\" alt=\"\" width=\"1500\" height=\"765\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators.webp 1500w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators-300x153.webp 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators-1024x522.webp 1024w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators-768x392.webp 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators-600x306.webp 600w\" sizes=\"auto, (max-width: 1500px) 100vw, 1500px\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"101\">Modelo<\/td>\n<td width=\"246\">Capacidade (kvar)<\/td>\n<td width=\"71\">Tens\u00e3o (V)<\/td>\n<td width=\"113\">Dimens\u00f5es (L*A*P) (mm)<\/td>\n<td width=\"133\">Arrefecimento<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.23-2L-R<\/td>\n<td>20Kvar\/30Kvar\/35Kvar<\/td>\n<td>230 V<\/td>\n<td>380x424x88<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.23-2L-R<\/td>\n<td>50Kvar\/70Kvar\/100Kvar<\/td>\n<td>230 V<\/td>\n<td>500x550x130<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.4-4L-R<\/td>\n<td>10Kvar\/15Kvar\/20Kvar\/30Kvar\/35Kvar<\/td>\n<td>400 V<\/td>\n<td>380x424x88<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.4-4L-R<\/td>\n<td>50Kvar\/75Kvar\/100Kvar\/150Kvar<\/td>\n<td>400 V<\/td>\n<td>500x550x130<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.5-4L-R<\/td>\n<td>85 kVAr<\/td>\n<td>500 V<\/td>\n<td>500x550x130<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.69-4L-R<\/td>\n<td>120 kVAr<\/td>\n<td>690 V<\/td>\n<td>500x550x130<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>A especifica\u00e7\u00e3o limita-se aos modelos padr\u00e3o; est\u00e3o dispon\u00edveis outras dimens\u00f5es mediante pedido.<\/p>\n<p><!-- CNBYG-HUB-RESOURCES-START --><\/p>\n<section>\n<h2>Centro de recursos de produtos SVG \/ ASVG<\/h2>\n<p>O Gerador Est\u00e1tico de Energia Reativa (SVG) e o Gerador Est\u00e1tico Avan\u00e7ado de Energia Reativa (ASVG) s\u00e3o designa\u00e7\u00f5es de linhas de produtos destinadas a projetos de compensa\u00e7\u00e3o din\u00e2mica de pot\u00eancia reativa. A CNBYG avalia os requisitos de resposta, a gama de pot\u00eancia reativa, as condi\u00e7\u00f5es de liga\u00e7\u00e3o, a varia\u00e7\u00e3o da carga, os equipamentos existentes e as restri\u00e7\u00f5es de instala\u00e7\u00e3o com base nos dados do projeto. Uma p\u00e1gina de produto n\u00e3o constitui uma garantia de desempenho do fator de pot\u00eancia, da tens\u00e3o ou de conformidade.<\/p>\n<p><a href=\"\/pt\/contact-us\/\">Discutir uma aplica\u00e7\u00e3o SVG\/ASVG<\/a><\/p>\n<\/section>\n<section>\n<h2>Pontos de entrada para aplica\u00e7\u00f5es<\/h2>\n<div>\n<article>\n<h3><a href=\"https:\/\/cnbygele.com\/pt\/blog\/svg-vs-asvg-how-to-choose-for-industrial-plants\/\">Cargas industriais com varia\u00e7\u00f5es r\u00e1pidas<\/a><\/h3>\n<p>Utilize o artigo comparativo para preparar quest\u00f5es t\u00e9cnicas e, em seguida, valide os dados da aplica\u00e7\u00e3o.<\/p>\n<\/article>\n<article>\n<h3><a href=\"https:\/\/cnbygele.com\/pt\/blog\/ev-charging-station-voltage-fluctuation-svg-guide\/\">Carregamento de ve\u00edculos el\u00e9tricos e flutua\u00e7\u00f5es de tens\u00e3o<\/a><\/h3>\n<p>Os perfis de carregamento e as condi\u00e7\u00f5es a montante devem ser analisados no ponto de liga\u00e7\u00e3o do projeto \u00e0 rede.<\/p>\n<\/article>\n<article>\n<h3><a href=\"https:\/\/cnbygele.com\/pt\/blog\/photovoltaic-inverter-harmonics-svg-apf-mitigation\/\">Aplica\u00e7\u00f5es com inversores fotovoltaicos<\/a><\/h3>\n<p>Defina separadamente os objetivos de pot\u00eancia reativa e de harm\u00f3nicas antes de especificar o equipamento.<\/p>\n<\/article>\n<article>\n<h3><a href=\"https:\/\/cnbygele.com\/pt\/blog\/marine-shipbuilding-power-quality-welding-shore-power\/\">Ind\u00fastria naval e constru\u00e7\u00e3o naval<\/a><\/h3>\n<p>Analise as restri\u00e7\u00f5es relativas \u00e0 alimenta\u00e7\u00e3o el\u00e9trica em terra, \u00e0 soldadura e \u00e0 instala\u00e7\u00e3o para o projeto espec\u00edfico da embarca\u00e7\u00e3o ou do estaleiro.<\/p>\n<\/article>\n<\/div>\n<\/section>\n<section>\n<h2>Par\u00e2metros para a sele\u00e7\u00e3o de SVG \/ ASVG<\/h2>\n<ul>\n<li>Diagrama unifilar, tens\u00e3o nominal, frequ\u00eancia, capacidade do transformador e localiza\u00e7\u00e3o da instala\u00e7\u00e3o<\/li>\n<li>Perfil de pot\u00eancia reativa, objetivo do fator de pot\u00eancia, varia\u00e7\u00e3o da carga e dados de tens\u00e3o relevantes<\/li>\n<li>Baterias de condensadores, reat\u00e2ncias, equipamentos de filtragem, prote\u00e7\u00e3o e interfaces de controlo existentes<\/li>\n<li>Restri\u00e7\u00f5es ambientais, de inv\u00f3lucro, t\u00e9rmicas, de cablagem e de coloca\u00e7\u00e3o em servi\u00e7o<\/li>\n<\/ul>\n<p>Para sistemas com um problema distinto de corrente harm\u00f3nica, consulte o <a href=\"https:\/\/cnbygele.com\/pt\/product\/ahf-active-harmonic-filter-harmonic-control\/\">Centro de produtos AHF\/APF<\/a> e determine se os objetivos exigem equipamentos coordenados.<\/p>\n<\/section>\n<section>\n<h2>Recursos t\u00e9cnicos selecionados<\/h2>\n<p>Utilize estes artigos para enquadrar a quest\u00e3o t\u00e9cnica antes de solicitar uma recomenda\u00e7\u00e3o para o projeto.<\/p>\n<ul>\n<li><a href=\"https:\/\/cnbygele.com\/pt\/blog\/svg-vs-asvg-how-to-choose-for-industrial-plants\/\">SVG vs. ASVG: como escolher para instala\u00e7\u00f5es industriais<\/a><\/li>\n<li><a href=\"https:\/\/cnbygele.com\/pt\/blog\/advanced-static-var-generator-asvg-explained\/\">Gerador Avan\u00e7ado Est\u00e1tico de Pot\u00eancia Reativa (ASVG): explica\u00e7\u00e3o<\/a><\/li>\n<li><a href=\"https:\/\/cnbygele.com\/pt\/blog\/ev-charging-station-voltage-fluctuation-svg-guide\/\">Flutua\u00e7\u00f5es de tens\u00e3o em esta\u00e7\u00f5es de carregamento de ve\u00edculos el\u00e9tricos e SVG<\/a><\/li>\n<li><a href=\"https:\/\/cnbygele.com\/pt\/blog\/photovoltaic-inverter-harmonics-svg-apf-mitigation\/\">Harm\u00f3nicas em inversores fotovoltaicos: mitiga\u00e7\u00e3o com SVG e APF<\/a><\/li>\n<li><a href=\"https:\/\/cnbygele.com\/pt\/blog\/static-var-compensation-system-design-basics\/\">Fundamentos da conce\u00e7\u00e3o de sistemas de compensa\u00e7\u00e3o est\u00e1tica de pot\u00eancia reativa<\/a><\/li>\n<li><a href=\"https:\/\/cnbygele.com\/pt\/blog\/marine-shipbuilding-power-quality-welding-shore-power\/\">Qualidade da energia el\u00e9trica na constru\u00e7\u00e3o naval, soldadura e alimenta\u00e7\u00e3o el\u00e9trica em terra<\/a><\/li>\n<\/ul>\n<\/section>\n<section>\n<h2>Informa\u00e7\u00f5es sobre o fabricante e pedidos de cota\u00e7\u00e3o<\/h2>\n<p>Para uma consulta com o fabricante, forne\u00e7a os dados el\u00e9tricos do projeto e as restri\u00e7\u00f5es de instala\u00e7\u00e3o, em vez de solicitar uma classifica\u00e7\u00e3o com base apenas numa palavra-chave. A CNBYG pode discutir a disponibilidade das linhas de produtos, a documenta\u00e7\u00e3o t\u00e9cnica e os dados do projeto atrav\u00e9s do <a href=\"\/pt\/contact-us\/\">p\u00e1gina de contacto<\/a>.<\/p>\n<\/section>\n<section>\n<h2>Perguntas frequentes<\/h2>\n<h3>O SVG \u00e9 adequado para todas as aplica\u00e7\u00f5es de pot\u00eancia reativa?<\/h3>\n<p>N\u00e3o. A adequa\u00e7\u00e3o depende do sistema el\u00e9trico, da resposta necess\u00e1ria, do perfil de carga, dos equipamentos existentes e dos requisitos do projeto.<\/p>\n<h3>O que significa \u201cASVG\u201d neste site?<\/h3>\n<p>\u00c9 a terminologia utilizada pela CNBYG para o seu produto Advanced Static Var Generator (gerador est\u00e1tico avan\u00e7ado de pot\u00eancia reativa). Confirme as fun\u00e7\u00f5es e a configura\u00e7\u00e3o com base na documenta\u00e7\u00e3o do produto aplic\u00e1vel e nos dados da aplica\u00e7\u00e3o.<\/p>\n<\/section>\n<p><!-- CNBYG-HUB-RESOURCES-END --><\/p>","protected":false},"excerpt":{"rendered":"<p>Os nossos compensadores est\u00e1ticos de pot\u00eancia reativa (SVG) oferecem uma solu\u00e7\u00e3o ideal para problemas relacionados com a estabilidade da rede, o fator de pot\u00eancia e as necessidades de pot\u00eancia reativa em diversas aplica\u00e7\u00f5es industriais. Estes equipamentos caracterizam-se por um funcionamento extremamente r\u00e1pido, um design compacto e uma excelente rela\u00e7\u00e3o custo-benef\u00edcio, garantindo uma resposta imediata \u00e0s perturba\u00e7\u00f5es nos sistemas el\u00e9tricos de m\u00e9dia e baixa tens\u00e3o. Atrav\u00e9s da compensa\u00e7\u00e3o da pot\u00eancia reativa, aumentam significativamente a vida \u00fatil das instala\u00e7\u00f5es, melhoram a fiabilidade dos processos de produ\u00e7\u00e3o, otimizam o desempenho do sistema e reduzem as perdas de transmiss\u00e3o, cumprindo simultaneamente os mais rigorosos padr\u00f5es de qualidade de energia.<\/p>","protected":false},"featured_media":1313,"template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[33,30],"product_tag":[],"class_list":["post-1291","product","type-product","status-publish","has-post-thumbnail","product_cat-power-quality-system","product_cat-products","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/product\/1291","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/media\/1313"}],"wp:attachment":[{"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/media?parent=1291"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/product_brand?post=1291"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/product_cat?post=1291"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/product_tag?post=1291"}],"curies":[{"name":"bem jogado","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}