{"id":1296,"date":"2026-04-29T10:02:18","date_gmt":"2026-04-29T02:02:18","guid":{"rendered":"https:\/\/w6pown520g.wpdns.site\/?post_type=product&#038;p=1296"},"modified":"2026-10-23T09:56:54","modified_gmt":"2026-10-23T01:56:54","slug":"jkw-series-reactive-power-automatic-compensation-controller","status":"publish","type":"product","link":"https:\/\/cnbygele.com\/pt\/product\/jkw-series-reactive-power-automatic-compensation-controller\/","title":{"rendered":"Controlador Autom\u00e1tico de Pot\u00eancia Reativa da S\u00e9rie JKW"},"content":{"rendered":"<h2>Escolha o controlador JKW exato antes de efetuar a encomenda<\/h2>\n<p>Esta p\u00e1gina apresenta v\u00e1rios modelos de controladores; a designa\u00e7\u00e3o da fam\u00edlia JKW n\u00e3o garante que tenham dimens\u00f5es de painel, alimenta\u00e7\u00e3o, sa\u00eddas ou comportamento de comuta\u00e7\u00e3o id\u00eanticos. Compare o c\u00f3digo completo do modelo encomendado com o desenho do quadro el\u00e9trico existente e o manual atualizado do fabricante.<\/p>\n<div style=\"overflow-x:auto;max-width:100%\">\n<table>\n<thead>\n<tr>\n<th>Rever item<\/th>\n<th>Informa\u00e7\u00f5es a fornecer juntamente com o pedido de informa\u00e7\u00e3o<\/th>\n<th>Requisitos que devem corresponder<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Identifica\u00e7\u00e3o e compatibilidade de instala\u00e7\u00e3o<\/td>\n<td>Fotografia da etiqueta do modelo original, dimens\u00f5es do recorte do painel e profundidade de montagem<\/td>\n<td>Modelo exato e desenho mec\u00e2nico<\/td>\n<\/tr>\n<tr>\n<td>Alimenta\u00e7\u00e3o e entrada do transformador de corrente (TC)<\/td>\n<td>Alimenta\u00e7\u00e3o efetiva, rela\u00e7\u00e3o de transforma\u00e7\u00e3o do TC, corrente nominal do secund\u00e1rio e posi\u00e7\u00e3o de amostragem<\/td>\n<td>Manual do controlador encomendado e esquema el\u00e9trico do quadro<\/td>\n<\/tr>\n<tr>\n<td>Escal\u00f5es e sa\u00eddas<\/td>\n<td>N\u00famero de escal\u00f5es, capacidades dos escal\u00f5es da bateria de condensadores e interface de contactores\/tir\u00edstores<\/td>\n<td>Tipo de sa\u00edda e requisitos de comuta\u00e7\u00e3o e descarga<\/td>\n<\/tr>\n<tr>\n<td>Compatibilidade de substitui\u00e7\u00e3o<\/td>\n<td>Mapa de terminais existente, fun\u00e7\u00f5es ativadas e c\u00f3digo do modelo de substitui\u00e7\u00e3o pretendido<\/td>\n<td>Compatibilidade documentada, n\u00e3o apenas designa\u00e7\u00f5es semelhantes<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Para um pedido de informa\u00e7\u00e3o sobre a substitui\u00e7\u00e3o de um JKW-285, forne\u00e7a a documenta\u00e7\u00e3o desse modelo exato: as linhas do cat\u00e1logo abaixo n\u00e3o comprovam, por si s\u00f3, a equival\u00eancia com o JKW-285. Confirme as informa\u00e7\u00f5es antigas pouco claras ou inconsistentes com a ficha t\u00e9cnica atual do fornecedor antes de configurar um controlador ou aprovar uma substitui\u00e7\u00e3o.<\/p>\n<p>Para obter informa\u00e7\u00f5es sobre o contexto do sistema, consulte o <a href=\"https:\/\/cnbygele.com\/pt\/blog\/leading-vs-lagging-current-power-factor\/\">guia sobre fatores de pot\u00eancia adiantados e atrasados<\/a> e <a href=\"https:\/\/cnbygele.com\/pt\/blog\/static-var-generator-svg-capacity-selection-and-technical-parameter-guide\/\">guia de dimensionamento da compensa\u00e7\u00e3o de pot\u00eancia reativa<\/a>. Um controlador de bancos de condensadores por escal\u00f5es e um SVG t\u00eam fun\u00e7\u00f5es diferentes; n\u00e3o devem ser considerados substitutos diretos.<\/p>\n<h2><strong><b>Descri\u00e7\u00e3o do Produto<\/b><\/strong><\/h2>\n<p>O controlador autom\u00e1tico de compensa\u00e7\u00e3o de pot\u00eancia reativa da s\u00e9rie JKW (doravante designado por controlador) \u00e9 um equipamento especializado para a compensa\u00e7\u00e3o de pot\u00eancia reativa em sistemas de distribui\u00e7\u00e3o de baixa tens\u00e3o, concebido em conformidade com a norma industrial JBT9663-2013 da Rep\u00fablica Popular da China e com a norma do setor el\u00e9trico DUT597-1996. A sua grandeza f\u00edsica de amostragem \u00e9 a pot\u00eancia reativa. Apresenta vantagens como um design inovador, m\u00faltiplas fun\u00e7\u00f5es, bom desempenho de controlo e elevada fiabilidade. Ocupa uma posi\u00e7\u00e3o de lideran\u00e7a entre os produtos similares na China e disponibiliza um novo equipamento para a automatiza\u00e7\u00e3o da distribui\u00e7\u00e3o de energia.<\/p>\n<ul>\n<li>Utiliza tecnologia de amostragem de corrente alternada (CA);<\/li>\n<li>Utiliza o fator de pot\u00eancia fundamental e a pot\u00eancia reativa fundamental como grandezas f\u00edsicas de controlo, garantindo elevada precis\u00e3o de controlo, aus\u00eancia de oscila\u00e7\u00f5es de comuta\u00e7\u00e3o e insensibilidade \u00e0s harm\u00f3nicas;<\/li>\n<li>Funcionamento totalmente digital dos par\u00e2metros de controlo, f\u00e1cil de utilizar, configura\u00e7\u00e3o imediata e sem perda de dados em caso de falha de energia;<\/li>\n<li>Adota um controlo de otimiza\u00e7\u00e3o autom\u00e1tica para reduzir a frequ\u00eancia de comuta\u00e7\u00e3o e aumentar a vida \u00fatil do sistema;<\/li>\n<li>Elevada capacidade de resist\u00eancia a interfer\u00eancias, suportando impulsos de interfer\u00eancia de 2000 V diretamente introduzidos pela alimenta\u00e7\u00e3o el\u00e9trica, sem bloqueios nem perda de dados, garantindo um funcionamento est\u00e1vel e fi\u00e1vel;<\/li>\n<li>Visualiza\u00e7\u00e3o digital do fator de pot\u00eancia, da pot\u00eancia reativa, da tens\u00e3o, da corrente (lado prim\u00e1rio) e dos par\u00e2metros de controlo da rede el\u00e9trica;<\/li>\n<li>Disp\u00f5e de dois modos de funcionamento: modo de fator de pot\u00eancia e modo de controlo de pot\u00eancia reativa, facilitando a instala\u00e7\u00e3o e a configura\u00e7\u00e3o pelos utilizadores;<\/li>\n<li>Disp\u00f5e de fun\u00e7\u00f5es de dete\u00e7\u00e3o e indica\u00e7\u00e3o de sobretens\u00e3o e subtens\u00e3o, permitindo desligar rapidamente o banco de condensadores para evitar o seu funcionamento em condi\u00e7\u00f5es de sobretens\u00e3o;<\/li>\n<li>Disp\u00f5e de uma fun\u00e7\u00e3o opcional de bloqueio de oscila\u00e7\u00f5es de comuta\u00e7\u00e3o (os utilizadores devem especific\u00e1-la no momento da encomenda);<\/li>\n<li>Disp\u00f5e de uma fun\u00e7\u00e3o opcional de atraso de 200 segundos entre o corte e a liga\u00e7\u00e3o de cada conjunto individual de condensadores. Este intervalo garante um tempo de descarga suficiente ap\u00f3s o desligamento do banco de condensadores, reduzindo o impacto na rede el\u00e9trica quando os condensadores voltam a entrar em funcionamento (os utilizadores devem especificar esta op\u00e7\u00e3o no momento da encomenda);<\/li>\n<li>A resist\u00eancia de entrada do sinal de amostragem de corrente \u00e9 inferior a 0,05 ohms, podendo o sinal ser obtido diretamente do circuito de medi\u00e7\u00e3o;<\/li>\n<li>Disp\u00f5e de dois modos de compensa\u00e7\u00e3o: fator de pot\u00eancia e pot\u00eancia reativa;<\/li>\n<li>O manual do utilizador apresenta um grande n\u00famero de m\u00e9todos de resolu\u00e7\u00e3o de problemas, facilitando a instala\u00e7\u00e3o e a configura\u00e7\u00e3o.<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1036\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/9.JKW_.webp\" alt=\"\" width=\"1566\" height=\"719\" \/><\/p>\n<h2><strong><b>Principais Par\u00e2metros T\u00e9cnicos <\/b><\/strong><\/h2>\n<p><strong>Par\u00e2metros B\u00e1sicos<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"298\">Projeto<\/td>\n<td width=\"298\">Par\u00e2metro<\/td>\n<\/tr>\n<tr>\n<td>Tens\u00e3o nominal<\/td>\n<td>CA 380 V\/CA 220 V +10%\/-10%<\/td>\n<\/tr>\n<tr>\n<td>Corrente nominal<\/td>\n<td>CA 0\u20135 A<\/td>\n<\/tr>\n<tr>\n<td>Frequ\u00eancia nominal<\/td>\n<td>50 Hz \u00b1 51 TP3T<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Par\u00e2metros de Controlo<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"239\">Projeto<\/td>\n<td width=\"413\">Par\u00e2metro<\/td>\n<\/tr>\n<tr>\n<td>Sensibilidade<\/td>\n<td>100 mA<\/td>\n<\/tr>\n<tr>\n<td>Predefini\u00e7\u00e3o do COS \u03a6 pretendido<\/td>\n<td>0,70-1,00; Incremento de 0,01; Predefini\u00e7\u00e3o de f\u00e1brica: 0,95<\/td>\n<\/tr>\n<tr>\n<td>Atraso de comuta\u00e7\u00e3o<\/td>\n<td>1~250 s<\/td>\n<\/tr>\n<tr>\n<td>Prote\u00e7\u00e3o contra sobretens\u00e3o<\/td>\n<td>380~500\/230~260 V; Incremento de 1 V; Diferen\u00e7a de retorno: 6 V<\/td>\n<\/tr>\n<tr>\n<td>Prote\u00e7\u00e3o contra subtens\u00e3o<\/td>\n<td>340 V\/180 V; Diferen\u00e7a de retorno: 6 V<\/td>\n<\/tr>\n<tr>\n<td>Altera\u00e7\u00f5es do TC<\/td>\n<td>50\/5 A~4000\/5 A; Incremento de 1<\/td>\n<\/tr>\n<tr>\n<td>Capacidade capacitiva<\/td>\n<td>0~125 kvar, predefini\u00e7\u00e3o de f\u00e1brica de 5 kvar por cada ramo<\/td>\n<\/tr>\n<tr>\n<td>Capacidade nominal dos contactos<\/td>\n<td>380 V \u00d7 5 A\/220 V \u00d7 7 A por ramo<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Precis\u00e3o da medi\u00e7\u00e3o<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"298\">Projeto<\/td>\n<td width=\"298\">Par\u00e2metro<\/td>\n<\/tr>\n<tr>\n<td>Tens\u00e3o<\/td>\n<td>\u00b11,01 TP3T<\/td>\n<\/tr>\n<tr>\n<td>Atual<\/td>\n<td>\u00b11,01 TP3T<\/td>\n<\/tr>\n<tr>\n<td>Fator de pot\u00eancia<\/td>\n<td>\u00b11,01 TP3T<\/td>\n<\/tr>\n<tr>\n<td>Pot\u00eancia Reativa<\/td>\n<td>\u00b12,01 %<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Intervalo de regula\u00e7\u00e3o e valores de f\u00e1brica dos par\u00e2metros de controlo<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"101\">C\u00f3digo do par\u00e2metro<\/td>\n<td width=\"246\">Significado<\/td>\n<td width=\"170\">Configura\u00e7\u00e3o<\/td>\n<td width=\"146\">Intervalo ajust\u00e1vel<\/td>\n<\/tr>\n<tr>\n<td>PA-1<\/td>\n<td>COS predefinido<\/td>\n<td>Histerese 0,95<\/td>\n<td>Indutivo 0,8-100<\/td>\n<\/tr>\n<tr>\n<td>PA-2<\/td>\n<td>Atraso predefinido<\/td>\n<td>30 s<\/td>\n<td>1-250 s<\/td>\n<\/tr>\n<tr>\n<td>PA-3<\/td>\n<td>Sobretens\u00e3o predefinida<\/td>\n<td>430 V<\/td>\n<td>230~260 V\/380~500 V<\/td>\n<\/tr>\n<tr>\n<td>PA-4<\/td>\n<td>Pr\u00e9-configura\u00e7\u00e3o dos circuitos<\/td>\n<td>1-12<\/td>\n<td>1-12 circuitos<\/td>\n<\/tr>\n<tr>\n<td>PA-4*<\/td>\n<td>Pr\u00e9-configura\u00e7\u00e3o da rela\u00e7\u00e3o de transforma\u00e7\u00e3o dos TI<\/td>\n<td>Configura\u00e7\u00e3o real<\/td>\n<td>50~4000<\/td>\n<\/tr>\n<tr>\n<td>C-01<\/td>\n<td>Pr\u00e9-configura\u00e7\u00e3o do condensador do 1.\u00ba circuito<\/td>\n<td>Configura\u00e7\u00e3o real<\/td>\n<td>0~150 kVAr<\/td>\n<\/tr>\n<tr>\n<td>C-12<\/td>\n<td>Pr\u00e9-configura\u00e7\u00e3o do condensador do 12.\u00ba circuito<\/td>\n<td>Configura\u00e7\u00e3o real<\/td>\n<td>0~150 kVAr<\/td>\n<\/tr>\n<tr>\n<td>PA-5<\/td>\n<td>Pr\u00e9-configura\u00e7\u00e3o do corte<\/td>\n<td>1.00<\/td>\n<td>0.70~0.70<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Nota: * No modo de controlo da pot\u00eancia reativa<\/p>\n<p><strong>Especifica\u00e7\u00f5es Principais<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"158\">Especifica\u00e7\u00f5es do modelo<\/td>\n<td width=\"146\">Dimens\u00e3o<\/td>\n<td width=\"155\">Tens\u00e3o nominal (V CA; confirmar de acordo com o modelo)<\/td>\n<td width=\"155\">Frequ\u00eancia do sinal<\/td>\n<\/tr>\n<tr>\n<td>JKW5C<\/td>\n<td>113x113mm<\/td>\n<td>AC220V1380V<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>JKW5B<\/td>\n<td>162x102mm<\/td>\n<td>AC380V<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>JKG2B<\/td>\n<td>162x102mm<\/td>\n<td>AC22OV<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>JKW1B<\/td>\n<td>140x102mm<\/td>\n<td>AC220V1380V<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>JKW58<\/td>\n<td>140x140mm<\/td>\n<td>AC220V1380V<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>JKWD5<\/td>\n<td>113x113mm<\/td>\n<td>AC220V\/380V<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>JKWF-12<\/td>\n<td>113x113mm<\/td>\n<td>AC220V<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>JKWF-16<\/td>\n<td>113x113mm<\/td>\n<td>AC22OV<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>JKWF-16<\/td>\n<td>140x140mm<\/td>\n<td>AC22OV<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>RPCF-16<\/td>\n<td>113x113mm<\/td>\n<td>AC380V<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td width=\"116\">Circuito<\/td>\n<td width=\"213\">Sa\u00edda<\/td>\n<td width=\"323\">M\u00e9todo de compensa\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td>Circuito 1-12<\/td>\n<td>Estado est\u00e1tico<\/td>\n<td>Compensa\u00e7\u00e3o de cos \u03c6<\/td>\n<\/tr>\n<tr>\n<td>Circuito 1-12<\/td>\n<td>Estado est\u00e1tico<\/td>\n<td>Compensa\u00e7\u00e3o de cos \u03c6<\/td>\n<\/tr>\n<tr>\n<td>Circuito 1-12<\/td>\n<td>Estado est\u00e1tico<\/td>\n<td>Compensa\u00e7\u00e3o de cos \u03c6<\/td>\n<\/tr>\n<tr>\n<td>Circuito 1-12<\/td>\n<td>Estado est\u00e1tico<\/td>\n<td>Compensa\u00e7\u00e3o de cos \u03c6<\/td>\n<\/tr>\n<tr>\n<td>Circuito 1-12<\/td>\n<td>Estado est\u00e1tico<\/td>\n<td>Compensa\u00e7\u00e3o de cos \u03c6<\/td>\n<\/tr>\n<tr>\n<td>Circuito 1-12<\/td>\n<td>DC12V<\/td>\n<td>Compensa\u00e7\u00e3o de cos \u03c6<\/td>\n<\/tr>\n<tr>\n<td>Circuito 1-12<\/td>\n<td>Estado est\u00e1tico\/DC12V<\/td>\n<td>Compensa\u00e7\u00e3o de cos \u03c6 + subcompensa\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td>Circuito 1-16<\/td>\n<td>DC12V<\/td>\n<td>Compensa\u00e7\u00e3o de cos \u03c6 + subcompensa\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td>Circuito 1-16<\/td>\n<td>Estado est\u00e1tico<\/td>\n<td>Compensa\u00e7\u00e3o de cos \u03c6 + subcompensa\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td>Circuito 1-16<\/td>\n<td>Estado est\u00e1tico\/DC12V<\/td>\n<td>Compensa\u00e7\u00e3o de cos \u03c6<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>M\u00e9todo de cablagem<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1037\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/10.JKW_-scaled.webp\" alt=\"\" width=\"772\" height=\"2560\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>O controlador autom\u00e1tico de compensa\u00e7\u00e3o de pot\u00eancia reativa da s\u00e9rie JKW utiliza tecnologia de amostragem de corrente alternada (CA), recorrendo ao fator de pot\u00eancia fundamental e \u00e0 pot\u00eancia reativa fundamental como grandezas f\u00edsicas de controlo, para garantir uma elevada precis\u00e3o de controlo, aus\u00eancia de oscila\u00e7\u00f5es nas comuta\u00e7\u00f5es e insensibilidade \u00e0s harm\u00f3nicas. Todos os par\u00e2metros de controlo s\u00e3o definidos digitalmente, simplificando a utiliza\u00e7\u00e3o e evitando a perda de dados devido a falhas de energia. Este controlador utiliza um controlo de otimiza\u00e7\u00e3o autom\u00e1tica para reduzir a frequ\u00eancia de comuta\u00e7\u00e3o, prolongar a vida \u00fatil do sistema e oferece uma elevada capacidade de resist\u00eancia a interfer\u00eancias, suportando impulsos de interfer\u00eancia de 2000 V sem bloquear nem perder dados, garantindo um funcionamento est\u00e1vel e fi\u00e1vel.<\/p>","protected":false},"featured_media":1622,"template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[37,35],"product_tag":[],"class_list":["post-1296","product","type-product","status-publish","has-post-thumbnail","product_cat-intelligent-controller","product_cat-reactive-power-compensator","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/product\/1296","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/media\/1622"}],"wp:attachment":[{"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/media?parent=1296"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/product_brand?post=1296"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/product_cat?post=1296"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/product_tag?post=1296"}],"curies":[{"name":"bem jogado","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}