{"id":1297,"date":"2026-04-29T10:02:18","date_gmt":"2026-04-29T02:02:18","guid":{"rendered":"https:\/\/w6pown520g.wpdns.site\/?post_type=product&#038;p=1297"},"modified":"2026-06-29T15:23:16","modified_gmt":"2026-06-29T07:23:16","slug":"bsmjparallel-series-self-healing-low-voltage-parallel-capacitors","status":"publish","type":"product","link":"https:\/\/cnbygele.com\/pt\/product\/bsmjparallel-series-self-healing-low-voltage-parallel-capacitors\/","title":{"rendered":"Condensadores Paralelos de Baixa Tens\u00e3o Auto-Curativos da S\u00e9rie BSMJ (Paralelo)"},"content":{"rendered":"<h2><strong><b>Descri\u00e7\u00e3o do Produto<\/b><\/strong><\/h2>\n<p>Os condensadores paralelos de baixa tens\u00e3o auto-repar\u00e1veis s\u00e3o adequados para sistemas de energia com frequ\u00eancias de 50Hz ou 60Hz, sendo principalmente utilizados para melhorar o fator de pot\u00eancia, reduzir as perdas de pot\u00eancia reativa, melhorar a qualidade da tens\u00e3o e aproveitar a capacidade do transformador. \u00c9 o melhor produto de poupan\u00e7a de energia fortemente recomendado pelo pa\u00eds para utiliza\u00e7\u00e3o.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1048\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.BSMJ_.webp\" alt=\"\" width=\"1524\" height=\"824\" \/><\/p>\n<h2>Indicadores T\u00e9cnicos do Produto<\/h2>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"228\">Projeto<\/td>\n<td width=\"440\">Par\u00e2metro<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" width=\"75\">Condi\u00e7\u00f5es<br \/>\nde Utiliza\u00e7\u00e3o<\/td>\n<td>Temperatura ambiente<\/td>\n<td>-25\u2103~+50\u2103<\/td>\n<\/tr>\n<tr>\n<td>Humidade relativa<\/td>\n<td>85%<\/td>\n<\/tr>\n<tr>\n<td>Atitude<\/td>\n<td>\u22642000m<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Tens\u00e3o nominal<\/td>\n<td>250VAC, 400VAC, 450VAC, 525VAC, 690VAC, 750VAC, 1050VAC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Capacidade nominal<\/td>\n<td>1-100kvar<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Toler\u00e2ncia de capacidade<\/td>\n<td>-5~+10%<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Valor da tangente do \u00e2ngulo de perda<\/td>\n<td>\u00c0 tens\u00e3o nominal \u00e0 frequ\u00eancia de rede, tg 6 \u2264 0,11 TP3T a 20 \u2103<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Tens\u00e3o suportada em CA<\/td>\n<td width=\"440\">2,15 vezes a tens\u00e3o nominal entre polos durante 10 segundos, e 3kV<br \/>\nentre os postes durante 10 segundos<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Sobretens\u00e3o m\u00e1xima admiss\u00edvel<\/td>\n<td>1,1 vezes a tens\u00e3o nominal<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Corrente m\u00e1xima admiss\u00edvel<\/td>\n<td>1,30 vezes a corrente nominal<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Caracter\u00edsticas de autodescarga<\/td>\n<td width=\"440\">Aplicar uma tens\u00e3o cont\u00ednua de $\\sqrt{2}$ V ao condensador, desligar a fonte de alimenta\u00e7\u00e3o para<br \/>\n3 minutos, e a tens\u00e3o restante diminui 75V ou menos<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Em conformidade com as normas<\/td>\n<td>GB12747-2017\u3001IEC60831-2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimens\u00f5es do Produto<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1050\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/8.BSMJ_.webp\" alt=\"\" width=\"1920\" height=\"1950\" \/><\/p>\n<h2>Especifica\u00e7\u00f5es Principais<\/h2>\n<table>\n<tbody>\n<tr>\n<td width=\"97\">Modelo de produto<\/td>\n<td width=\"89\">Classificado<br \/>\ntens\u00e3o (kV)<\/td>\n<td width=\"110\">Classificado<br \/>\ncapacidade (kvar)<\/td>\n<td width=\"117\">Eletricidade total<br \/>\ncapacidade (u F)<\/td>\n<td width=\"82\">Classificado<br \/>\ncorrente (A)<\/td>\n<td width=\"131\">Dimens\u00e3o de fronteira<br \/>\nC x L x A (mm)<\/td>\n<\/tr>\n<tr>\n<td>0.25-3-3YN<\/td>\n<td>0.25<\/td>\n<td>3<\/td>\n<td>153<\/td>\n<td>4<\/td>\n<td>-170x60x125<\/td>\n<\/tr>\n<tr>\n<td>0.25-5-3YN<\/td>\n<td>0.25<\/td>\n<td>5<\/td>\n<td>255<\/td>\n<td>6.7<\/td>\n<td>170x60x125<\/td>\n<\/tr>\n<tr>\n<td>0.25-7.5-3YN<\/td>\n<td>0.25<\/td>\n<td>7.5<\/td>\n<td>382<\/td>\n<td>10<\/td>\n<td>170x60x125<\/td>\n<\/tr>\n<tr>\n<td>0,25-10-3YN<\/td>\n<td>0.25<\/td>\n<td>10<\/td>\n<td>509<\/td>\n<td>13.3<\/td>\n<td>170x60x125<\/td>\n<\/tr>\n<tr>\n<td>0.25-15-3YN<\/td>\n<td>0.25<\/td>\n<td>15<\/td>\n<td>764<\/td>\n<td>20<\/td>\n<td>170x89x200<\/td>\n<\/tr>\n<tr>\n<td>0.25-20-3YN<\/td>\n<td>0.25<\/td>\n<td>20<\/td>\n<td>1019<\/td>\n<td>26.7<\/td>\n<td>170x89x245<\/td>\n<\/tr>\n<tr>\n<td>0.25-25-3YN<\/td>\n<td>0.25<\/td>\n<td>25<\/td>\n<td>1273<\/td>\n<td>33.3<\/td>\n<td>170x89x300<\/td>\n<\/tr>\n<tr>\n<td>0,25-30-3YN<\/td>\n<td>0.25<\/td>\n<td>30<\/td>\n<td>1528<\/td>\n<td>40<\/td>\n<td>170x89x300<\/td>\n<\/tr>\n<tr>\n<td>0.45-5-3<\/td>\n<td>0.45<\/td>\n<td>5<\/td>\n<td>79<\/td>\n<td>6.4<\/td>\n<td>170x60x105<\/td>\n<\/tr>\n<tr>\n<td>0.45-6-3<\/td>\n<td>0.45<\/td>\n<td>6<\/td>\n<td>94<\/td>\n<td>7.7<\/td>\n<td>170x60x105<\/td>\n<\/tr>\n<tr>\n<td>0.45-7-3<\/td>\n<td>0.45<\/td>\n<td>7<\/td>\n<td>110<\/td>\n<td>9<\/td>\n<td>170x60x105<\/td>\n<\/tr>\n<tr>\n<td>0.45-7.5-3<\/td>\n<td>0.45<\/td>\n<td>7.5<\/td>\n<td>118<\/td>\n<td>9.6<\/td>\n<td>170x60x105<\/td>\n<\/tr>\n<tr>\n<td>0.45-8-3<\/td>\n<td>0.45<\/td>\n<td>8<\/td>\n<td>126<\/td>\n<td>10.3<\/td>\n<td>170x60x105<\/td>\n<\/tr>\n<tr>\n<td>0.45-10-3<\/td>\n<td>0.45<\/td>\n<td>10<\/td>\n<td>157<\/td>\n<td>12.8<\/td>\n<td>170x60x125<\/td>\n<\/tr>\n<tr>\n<td>0.45-12-3<\/td>\n<td>0.45<\/td>\n<td>12<\/td>\n<td>189<\/td>\n<td>15.4<\/td>\n<td>170x60x175<\/td>\n<\/tr>\n<tr>\n<td>0.45-14-3<\/td>\n<td>0.45<\/td>\n<td>14<\/td>\n<td>220<\/td>\n<td>18<\/td>\n<td>170x60x175<\/td>\n<\/tr>\n<tr>\n<td>0.45-15-3<\/td>\n<td>0.45<\/td>\n<td>15<\/td>\n<td>236<\/td>\n<td>19.2<\/td>\n<td>170x60x175<\/td>\n<\/tr>\n<tr>\n<td>0.45-16-3<\/td>\n<td>0.45<\/td>\n<td>16<\/td>\n<td>252<\/td>\n<td>20.5<\/td>\n<td>170x60x175<\/td>\n<\/tr>\n<tr>\n<td>0.45-18-3<\/td>\n<td>0.45<\/td>\n<td>18<\/td>\n<td>283<\/td>\n<td>23.1<\/td>\n<td>170x60x210<\/td>\n<\/tr>\n<tr>\n<td>0.45-20-3<\/td>\n<td>0.45<\/td>\n<td>20<\/td>\n<td>314<\/td>\n<td>25.7<\/td>\n<td>170x60x210<\/td>\n<\/tr>\n<tr>\n<td>0.45-25-3<\/td>\n<td>0.45<\/td>\n<td>25<\/td>\n<td>393<\/td>\n<td>32.1<\/td>\n<td>170x89x200<\/td>\n<\/tr>\n<tr>\n<td>0.45-30-3<\/td>\n<td>0.45<\/td>\n<td>30<\/td>\n<td>472<\/td>\n<td>38.5<\/td>\n<td>170x89x200<\/td>\n<\/tr>\n<tr>\n<td>0.45-40-3<\/td>\n<td>0.45<\/td>\n<td>40<\/td>\n<td>629<\/td>\n<td>51.3<\/td>\n<td>170x89x245<\/td>\n<\/tr>\n<tr>\n<td>0.45-50-3<\/td>\n<td>0.45<\/td>\n<td>50<\/td>\n<td>786<\/td>\n<td>64.2<\/td>\n<td>170x89x300<\/td>\n<\/tr>\n<tr>\n<td>0.45-60-3<\/td>\n<td>0.45<\/td>\n<td>60<\/td>\n<td>943<\/td>\n<td>77<\/td>\n<td>270x120x250<\/td>\n<\/tr>\n<tr>\n<td>0.45-70-3<\/td>\n<td>0.45<\/td>\n<td>20<\/td>\n<td>1100<\/td>\n<td>89.8<\/td>\n<td>270x120x300<\/td>\n<\/tr>\n<tr>\n<td>0.45-80-3<\/td>\n<td>0.45<\/td>\n<td>80<\/td>\n<td>1258<\/td>\n<td>102.6<\/td>\n<td>270x120x300<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Instru\u00e7\u00f5es<\/h2>\n<p><strong>Instru\u00e7\u00f5es de Utiliza\u00e7\u00e3o<\/strong><\/p>\n<ul>\n<li>Transportar na embalagem original de f\u00e1brica; manusear com cuidado.<\/li>\n<li>Guardar em ambiente interior seco e com g\u00e1s n\u00e3o corrosivo.<\/li>\n<\/ul>\n<p><strong>Inspe\u00e7\u00e3o de aceita\u00e7\u00e3o pelo utilizador<\/strong><\/p>\n<ul>\n<li>Certifique-se de que o modelo da placa de caracter\u00edsticas corresponde ao produto adquirido antes de o utilizar.<\/li>\n<li>Ensaio de capacidade: Realizar conforme o ponto 4.2, utilizando instrumentos com um erro relativo \u22642%.<\/li>\n<li>Ensaio de tens\u00e3o de resist\u00eancia: Aplicar 75% da tens\u00e3o especificada no ponto 4.3.<\/li>\n<\/ul>\n<p><strong>Instala\u00e7\u00e3o e funcionamento<\/strong><\/p>\n<ul>\n<li>Instalar em espa\u00e7o interior, para utiliza\u00e7\u00e3o a uma altitude inferior a 2000m.<\/li>\n<li>Temperatura ambiente -25 a +50 \u2103, humidade &lt;85%; vers\u00e3o para baixas temperaturas (-40 a +50 \u2103) dispon\u00edvel mediante pedido.<\/li>\n<li>Local de instala\u00e7\u00e3o: evitar luz solar direta, chuva, excesso de p\u00f3 e vibra\u00e7\u00e3o severa; espa\u00e7amento &gt;30mm; garantir boa ventila\u00e7\u00e3o e dissipa\u00e7\u00e3o de calor em temperaturas elevadas de ver\u00e3o.<\/li>\n<li>Antes da instala\u00e7\u00e3o, considere a subida de tens\u00e3o ap\u00f3s a entrada do capacitor para evitar a opera\u00e7\u00e3o prolongada sob sobretens\u00e3o; verifique a forma de onda da tens\u00e3o e as caracter\u00edsticas da rede; tome medidas para limitar os harm\u00f3nicos, caso existam fontes harm\u00f3nicas.<\/li>\n<li>Quando ligado em paralelo com um motor de indu\u00e7\u00e3o, a corrente do condensador \u00e9 inferior a 90% da corrente em vazio do motor.<\/li>\n<li>Utilize fios de cobre flex\u00edveis para os terminais de fase e terra, garanta um bom contacto; verifique os terminais regularmente para evitar danos.<\/li>\n<li>Intervalo entre a desconex\u00e3o e a reconex\u00e3o &gt;3 min (tempo de autodescarga) para evitar danos por sobretens\u00e3o.<\/li>\n<\/ul>\n<p><strong>Instru\u00e7\u00f5es de encomenda<\/strong><\/p>\n<ul>\n<li>Os utilizadores devem fornecer a tens\u00e3o nominal, a capacidade nominal, o n\u00famero de fases e outros par\u00e2metros do produto.<\/li>\n<li>Os utilizadores devem fazer o seu melhor para fornecer algumas caracter\u00edsticas do local de utiliza\u00e7\u00e3o.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Os condensadores paralelos de baixa tens\u00e3o com autocorre\u00e7\u00e3o da s\u00e9rie BSMJ (Parallel) s\u00e3o compactos e leves, utilizando uma pel\u00edcula de polipropileno metalizado como diel\u00e9trico. T\u00eam apenas 1\/4 do volume e 1\/5 do peso dos produtos mais antigos. A sua forte capacidade de autorrecupera\u00e7\u00e3o permite-lhes recuperar rapidamente de avarias diel\u00e9tricas localizadas causadas por sobretens\u00e3o, garantindo uma elevada fiabilidade. Os condensadores apresentam uma perda real inferior a 0,11 TP3T, oferecendo vantagens como baixo consumo de energia, baixa gera\u00e7\u00e3o de calor, baixo aumento de temperatura, longa vida \u00fatil e poupan\u00e7a de energia.<\/p>","protected":false},"featured_media":1349,"template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[38,35],"product_tag":[],"class_list":["post-1297","product","type-product","status-publish","has-post-thumbnail","product_cat-power-film-capacitor","product_cat-reactive-power-compensator","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/product\/1297","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/media\/1349"}],"wp:attachment":[{"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/media?parent=1297"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/product_brand?post=1297"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/product_cat?post=1297"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/product_tag?post=1297"}],"curies":[{"name":"bem jogado","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}