{"id":1688,"date":"2026-05-21T11:53:39","date_gmt":"2026-05-21T03:53:39","guid":{"rendered":"https:\/\/w6pown520g.wpdns.site\/?post_type=product&#038;p=1688"},"modified":"2026-06-29T16:02:44","modified_gmt":"2026-06-29T08:02:44","slug":"ahf-active-harmonic-filter-harmonic-control-2","status":"publish","type":"product","link":"https:\/\/cnbygele.com\/pt\/product\/ahf-active-harmonic-filter-harmonic-control-2\/","title":{"rendered":"Filtro Ativo de Harm\u00f3nicas AHF \u2013 Controlo de Harm\u00f3nicas"},"content":{"rendered":"<h2>Descri\u00e7\u00e3o do Produto<\/h2>\n<p>O filtro ativo de pot\u00eancia AHF consegue monitorizar eficazmente as harm\u00f3nicas e extrair as respetivas correntes harm\u00f3nicas. O equipamento gera correntes harm\u00f3nicas inversas atrav\u00e9s de IGBT, suprimindo completamente as harm\u00f3nicas no ponto de liga\u00e7\u00e3o do equipamento e evitando perdas mais elevadas causadas pela circula\u00e7\u00e3o de correntes harm\u00f3nicas atrav\u00e9s de disjuntores ou transformadores. Simultaneamente, o equipamento tamb\u00e9m consegue gerir a pot\u00eancia reativa e os fen\u00f3menos de desequil\u00edbrio trif\u00e1sico, proporcionando uma verdadeira gest\u00e3o integrada e inteligente da qualidade da energia el\u00e9trica. O AHF consegue filtrar eficazmente as harm\u00f3nicas da 2.\u00aa \u00e0 50.\u00aa ordem.<\/p>\n<ul>\n<li>Melhorar a qualidade da alimenta\u00e7\u00e3o el\u00e9trica, aumentar a fiabilidade do funcionamento dos equipamentos e reduzir as perdas econ\u00f3micas causadas por avarias nos equipamentos<\/li>\n<li>Reduzir o aquecimento das linhas e o envelhecimento do isolamento, melhorando a seguran\u00e7a e a fiabilidade el\u00e9trica<\/li>\n<li>Reduzir a probabilidade de resson\u00e2ncia dos condensadores de compensa\u00e7\u00e3o e aumentar a seguran\u00e7a da instala\u00e7\u00e3o el\u00e9trica; cumprir os requisitos das normas nacionais<\/li>\n<li>Reduzir as interfer\u00eancias eletromagn\u00e9ticas causadas pelas harm\u00f3nicas e assegurar o funcionamento normal dos sistemas de comunica\u00e7\u00e3o<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-1609 size-full\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control.webp\" alt=\"\" width=\"1500\" height=\"872\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control.webp 1500w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-300x174.webp 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-1024x595.webp 1024w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-768x446.webp 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-600x349.webp 600w\" sizes=\"auto, (max-width: 1500px) 100vw, 1500px\" \/><\/p>\n<p><strong><b>Princ\u00edpio de funcionamento do AHF:<\/b><\/strong><\/p>\n<p>O AHF funciona atrav\u00e9s da monitoriza\u00e7\u00e3o cont\u00ednua e em tempo real da corrente da carga, utilizando transformadores de corrente externos (CT). O seu processador digital de sinal de alta velocidade (DSP) interno extrai as componentes harm\u00f3nicas e a corrente reativa da forma de onda detetada e, em seguida, gera uma corrente de compensa\u00e7\u00e3o precisa em oposi\u00e7\u00e3o de fase. Esta corrente de compensa\u00e7\u00e3o \u00e9 injetada novamente na linha de alimenta\u00e7\u00e3o el\u00e9trica atrav\u00e9s de um inversor com trans\u00edstores bipolares de porta isolada (IGBT), cancelando eficazmente as harm\u00f3nicas e corrigindo o fator de pot\u00eancia. Como resultado, o AHF garante que a rede el\u00e9trica fornece apenas a corrente fundamental, com um fator de pot\u00eancia pr\u00f3ximo da unidade, assegurando uma alimenta\u00e7\u00e3o el\u00e9trica limpa e est\u00e1vel.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-945\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.AHF-Active-Harmonic-Filter-Harmonic-Control.webp\" alt=\"\" width=\"1500\" height=\"1693\" \/><\/p>\n<h2><strong><b>AHF de Montagem na Parede<\/b><\/strong><\/h2>\n<p><strong>Especifica\u00e7\u00f5es T\u00e9cnicas<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"164\">TIPO<\/td>\n<td width=\"122\">S\u00e9rie 230 V<\/td>\n<td width=\"122\">S\u00e9rie 400 V<\/td>\n<td width=\"122\">S\u00e9rie 500 V<\/td>\n<td width=\"122\">S\u00e9rie 690 V<\/td>\n<\/tr>\n<tr>\n<td>Capacidade<\/td>\n<td width=\"122\">30 A\/50 A\/75 A<br \/>\n100 A\/150 A\/200 A<\/td>\n<td width=\"122\">30 A\/50 A\/75 A<br \/>\n100 A\/150 A\/200 A<\/td>\n<td width=\"122\">30 A\/50 A\/75 A<br \/>\n100 A\/150 A\/200 A<\/td>\n<td width=\"122\">30 A\/50 A\/75 A<br \/>\n100 A\/150 A<\/td>\n<\/tr>\n<tr>\n<td>Tens\u00e3o<\/td>\n<td>230 V (\u00b120%)<\/td>\n<td>400 V (\u00b120%)<\/td>\n<td>500 V (\u00b120%)<\/td>\n<td>690 V (\u00b120%)<\/td>\n<\/tr>\n<tr>\n<td>Frequ\u00eancia<\/td>\n<td colspan=\"4\">50 Hz (\u00b15%)<\/td>\n<\/tr>\n<tr>\n<td>Fase<\/td>\n<td colspan=\"4\">3 fases<\/td>\n<\/tr>\n<tr>\n<td>Tempo de resposta<\/td>\n<td colspan=\"4\">&lt;5 ms<\/td>\n<\/tr>\n<tr>\n<td>Transformador de corrente<\/td>\n<td colspan=\"4\">150:5~10 000:5<\/td>\n<\/tr>\n<tr>\n<td>Efici\u00eancia e perdas<\/td>\n<td colspan=\"4\">Efici\u00eancia \u226597% (3 fases), perda \u226415 W\/A<\/td>\n<\/tr>\n<tr>\n<td>Fun\u00e7\u00e3o<\/td>\n<td colspan=\"4\">Elimina\u00e7\u00e3o de harm\u00f3nicos<\/td>\n<\/tr>\n<tr>\n<td>N\u00famero de m\u00f3dulos<\/td>\n<td colspan=\"4\" width=\"491\">Sem limita\u00e7\u00f5es. Um m\u00f3dulo de monitoriza\u00e7\u00e3o pode ser equipado com 32 m\u00f3dulos de atua\u00e7\u00e3o\/execu\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td>Protocolo de comunica\u00e7\u00e3o<\/td>\n<td colspan=\"4\">Modbus, TCP\/IP, CAN<\/td>\n<\/tr>\n<tr>\n<td>Altitude acima do n\u00edvel do mar<\/td>\n<td colspan=\"4\">&lt;2000m<\/td>\n<\/tr>\n<tr>\n<td>Temperatura<\/td>\n<td colspan=\"4\">-20~+50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Humidade<\/td>\n<td colspan=\"4\">&lt;90%<\/td>\n<\/tr>\n<tr>\n<td>Grau de polui\u00e7\u00e3o<\/td>\n<td colspan=\"4\">Inferior ao n\u00edvel 2<\/td>\n<\/tr>\n<tr>\n<td>Modo de compensa\u00e7\u00e3o<\/td>\n<td colspan=\"4\" width=\"491\">Supress\u00e3o de harm\u00f3nicas\/compensa\u00e7\u00e3o de pot\u00eancia reativa\/compensa\u00e7\u00e3o de desequil\u00edbrio,<\/p>\n<p>11 modos em qualquer combina\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td>Ru\u00eddo<\/td>\n<td>&lt;50 dB<\/td>\n<td>&lt;60 dB<\/td>\n<td colspan=\"2\">&lt;65 dB<\/td>\n<\/tr>\n<tr>\n<td>M\u00e9todo de instala\u00e7\u00e3o<\/td>\n<td colspan=\"4\">Montagem na parede<\/td>\n<\/tr>\n<tr>\n<td>Conformidade com as normas<\/td>\n<td colspan=\"4\">IEEE519\u3001IEC6100-3-6\u3001ER G5\/4\u3001CE, Conformidade EMC: EN 61000-6-4 Classe A<\/td>\n<\/tr>\n<tr>\n<td>Grau de prote\u00e7\u00e3o<\/td>\n<td colspan=\"4\">IP20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><b>Informa\u00e7\u00f5es sobre as dimens\u00f5es do produto<\/b><\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-947\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/4.AHF-Active-Harmonic-Filter-Harmonic-Control.webp\" alt=\"\" width=\"1500\" height=\"778\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"112\">Modelo<\/td>\n<td width=\"213\">Capacidade (kvar)<\/td>\n<td width=\"79\">Tens\u00e3o (V)<\/td>\n<td width=\"117\">Dimens\u00f5es (L*A*P) (mm)<\/td>\n<td width=\"140\">Arrefecimento<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.23-3L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>230 V<\/td>\n<td>480x570x175<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.23-3L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>230 V<\/td>\n<td>480x570x175<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.4-4L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>400 V<\/td>\n<td>480x570x175<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.4-4L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>400 V<\/td>\n<td>480x570x175<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.5-4L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>500 V<\/td>\n<td>480x570x175<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.69-4L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A<\/td>\n<td>690 V<\/td>\n<td>480x570x175<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>A especifica\u00e7\u00e3o limita-se aos modelos padr\u00e3o; est\u00e3o dispon\u00edveis outras dimens\u00f5es mediante pedido.<\/p>\n<h2><strong><b>AHF para montagem em bastidor<\/b><\/strong><\/h2>\n<p><strong>Especifica\u00e7\u00f5es T\u00e9cnicas<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"165\">TIPO<\/td>\n<td width=\"123\">S\u00e9rie 230 V<\/td>\n<td width=\"123\">S\u00e9rie 400 V<\/td>\n<td width=\"123\">S\u00e9rie 500 V<\/td>\n<td width=\"123\">S\u00e9rie 690 V<\/td>\n<\/tr>\n<tr>\n<td>Capacidade<\/td>\n<td width=\"123\">30 A\/50 A\/75 A<br \/>\n100 A\/150 A\/200 A<\/td>\n<td width=\"123\">30 A\/50 A\/75 A<br \/>\n100 A\/150 A\/200 A<\/td>\n<td width=\"123\">30 A\/50 A\/75 A<br \/>\n100 A\/150 A\/200 A<\/td>\n<td width=\"123\">30 A\/50 A\/75 A<br \/>\n100 A\/150 A<\/td>\n<\/tr>\n<tr>\n<td>Tens\u00e3o<\/td>\n<td>230 V (\u00b120%)<\/td>\n<td>400 V (\u00b120%)<\/td>\n<td>500 V (\u00b120%)<\/td>\n<td>690 V (\u00b120%)<\/td>\n<\/tr>\n<tr>\n<td>Frequ\u00eancia<\/td>\n<td colspan=\"4\">50 Hz (\u00b15%)<\/td>\n<\/tr>\n<tr>\n<td>Fase<\/td>\n<td colspan=\"4\">3 fases<\/td>\n<\/tr>\n<tr>\n<td>Tempo de resposta<\/td>\n<td colspan=\"4\">&lt;5 ms<\/td>\n<\/tr>\n<tr>\n<td>Transformador de corrente<\/td>\n<td colspan=\"4\">150:5~10 000:5<\/td>\n<\/tr>\n<tr>\n<td>Efici\u00eancia e perdas<\/td>\n<td colspan=\"4\">Efici\u00eancia \u226597% (3 fases), perda \u226415 W\/A<\/td>\n<\/tr>\n<tr>\n<td>Fun\u00e7\u00e3o<\/td>\n<td colspan=\"4\">Elimina\u00e7\u00e3o de harm\u00f3nicos<\/td>\n<\/tr>\n<tr>\n<td>N\u00famero de m\u00f3dulos<\/td>\n<td colspan=\"4\" width=\"493\">Sem limita\u00e7\u00f5es. Um m\u00f3dulo de monitoriza\u00e7\u00e3o pode ser equipado com 32 m\u00f3dulos de atua\u00e7\u00e3o\/execu\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td>Protocolo de comunica\u00e7\u00e3o<\/td>\n<td colspan=\"4\">Modbus, TCP\/IP, CAN<\/td>\n<\/tr>\n<tr>\n<td>Altitude acima do n\u00edvel do mar<\/td>\n<td colspan=\"4\">&lt;2000m<\/td>\n<\/tr>\n<tr>\n<td>Temperatura<\/td>\n<td colspan=\"4\">-20~+50 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Humidade<\/td>\n<td colspan=\"4\">&lt;90%<\/td>\n<\/tr>\n<tr>\n<td>Grau de polui\u00e7\u00e3o<\/td>\n<td colspan=\"4\">Inferior ao n\u00edvel 2<\/td>\n<\/tr>\n<tr>\n<td>Modo de compensa\u00e7\u00e3o<\/td>\n<td colspan=\"4\" width=\"493\">Supress\u00e3o de harm\u00f3nicas\/compensa\u00e7\u00e3o de pot\u00eancia reativa\/compensa\u00e7\u00e3o de desequil\u00edbrios, com 11 modos combin\u00e1veis livremente<\/td>\n<\/tr>\n<tr>\n<td>Ru\u00eddo<\/td>\n<td>&lt;50 dB<\/td>\n<td>&lt;60 dB<\/td>\n<td colspan=\"2\">&lt;65 dB<\/td>\n<\/tr>\n<tr>\n<td>M\u00e9todo de instala\u00e7\u00e3o<\/td>\n<td colspan=\"4\">Montagem em bastidor<\/td>\n<\/tr>\n<tr>\n<td>Conformidade com as normas<\/td>\n<td colspan=\"4\">IEEE519\u3001IEC6100-3-6\u3001ER G5\/4\u3001CE, Conformidade EMC: EN 61000-6-4 Classe A<\/td>\n<\/tr>\n<tr>\n<td>Grau de prote\u00e7\u00e3o<\/td>\n<td colspan=\"4\">IP20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong><b>Informa\u00e7\u00f5es sobre as dimens\u00f5es do produto<\/b><\/strong><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1610\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.1-AHF-Active-Harmonic-Filter-Harmonic-Control.webp\" alt=\"\" width=\"1500\" height=\"765\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.1-AHF-Active-Harmonic-Filter-Harmonic-Control.webp 1500w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.1-AHF-Active-Harmonic-Filter-Harmonic-Control-300x153.webp 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.1-AHF-Active-Harmonic-Filter-Harmonic-Control-1024x522.webp 1024w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.1-AHF-Active-Harmonic-Filter-Harmonic-Control-768x392.webp 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.1-AHF-Active-Harmonic-Filter-Harmonic-Control-600x306.webp 600w\" sizes=\"auto, (max-width: 1500px) 100vw, 1500px\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"112\">Modelo<\/td>\n<td width=\"208\">Capacidade (kvar)<\/td>\n<td width=\"81\">Tens\u00e3o (V)<\/td>\n<td width=\"120\">Dimens\u00f5es (L*A*P) (mm)<\/td>\n<td width=\"143\">Arrefecimento<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.23-3L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>230 V<\/td>\n<td>480x570x175<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.23-3L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>230 V<\/td>\n<td>480x570x175<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.4-4L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>400 V<\/td>\n<td>480x570x175<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.4-4L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>400 V<\/td>\n<td>480x570x175<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.5-4L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>500 V<\/td>\n<td>480x570x175<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.69-4L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A<\/td>\n<td>690 V<\/td>\n<td>480x570x175<\/td>\n<td>Arrefecimento por ventila\u00e7\u00e3o for\u00e7ada<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>A especifica\u00e7\u00e3o limita-se aos modelos padr\u00e3o; est\u00e3o dispon\u00edveis outras dimens\u00f5es mediante pedido.<\/p>","protected":false},"excerpt":{"rendered":"<p>Os filtros ativos de harm\u00f3nicas AHF melhoram a qualidade da energia el\u00e9trica e a fiabilidade dos equipamentos atrav\u00e9s do controlo das harm\u00f3nicas, reduzindo as perdas econ\u00f3micas causadas por avarias nos equipamentos. Reduzem o aquecimento das linhas e o envelhecimento do isolamento, aumentando a seguran\u00e7a e a fiabilidade el\u00e9trica. Al\u00e9m disso, reduzem a probabilidade de resson\u00e2ncia dos condensadores de compensa\u00e7\u00e3o, garantindo a seguran\u00e7a da instala\u00e7\u00e3o el\u00e9trica e a conformidade com as normas nacionais. O equipamento reduz as interfer\u00eancias eletromagn\u00e9ticas causadas pelas harm\u00f3nicas, assegurando o funcionamento normal dos sistemas de comunica\u00e7\u00e3o.<\/p>","protected":false},"featured_media":1606,"template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[33,30],"product_tag":[],"class_list":["post-1688","product","type-product","status-publish","has-post-thumbnail","product_cat-power-quality-system","product_cat-products","first","instock","downloadable","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/product\/1688","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/media\/1606"}],"wp:attachment":[{"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/media?parent=1688"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/product_brand?post=1688"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/product_cat?post=1688"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnbygele.com\/pt\/wp-json\/wp\/v2\/product_tag?post=1688"}],"curies":[{"name":"bem jogado","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}