{"id":2365,"date":"2026-08-13T09:00:00","date_gmt":"2026-08-13T01:00:00","guid":{"rendered":"https:\/\/cnbygele.com\/blog\/event-triggered-harmonic-logging-intermittent-loads\/"},"modified":"2026-08-24T17:23:46","modified_gmt":"2026-08-24T09:23:46","slug":"event-triggered-harmonic-logging-intermittent-loads","status":"publish","type":"post","link":"https:\/\/cnbygele.com\/tr\/blog\/event-triggered-harmonic-logging-intermittent-loads\/","title":{"rendered":"Ara\u015ft\u0131r\u0131labilir Kay\u0131tlarla S\u00fcreli Harmonik Olaylar\u0131 Yakalay\u0131n"},"content":{"rendered":"<div class=\"b2b-article\">\n<p style=\"margin:0 0 16px;line-height:1.7\">Aral\u0131kl\u0131 y\u00fck incelemeleri genellikle uzun vadeli ortalama e\u011filimlerden daha fazlas\u0131n\u0131 gerektirir. Olay tetiklemeli harmonik kayd\u0131, tan\u0131mlanm\u0131\u015f bir ko\u015ful ger\u00e7ekle\u015fti\u011finde belirli bir elektriksel s\u0131n\u0131r noktas\u0131nda neler ya\u015fand\u0131\u011f\u0131n\u0131 koruyabilir; bunun i\u00e7in tetikleme ayarlar\u0131n\u0131n, saatin, \u00f6l\u00e7\u00fcm cihaz\u0131 yap\u0131land\u0131rmas\u0131n\u0131n ve \u00e7al\u0131\u015fma durumunun kay\u0131tla birlikte saklanmas\u0131 gerekir.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Daha kapsaml\u0131 planlama ba\u011flam\u0131 i\u00e7in \u015fu y\u00f6ntemle ba\u015flay\u0131n: <a href=\"https:\/\/cnbygele.com\/tr\/power-quality-system-guides\/\">g\u00fc\u00e7 kalitesi sistem k\u0131lavuzlar\u0131<\/a>. Bu makale, olay kan\u0131tlar\u0131n\u0131n nas\u0131l d\u00fczenlenece\u011fini a\u00e7\u0131klar; temel nedeni belirlemez, belirli bir cihaz \u00f6nermez veya herhangi bir i\u015fletme sonucu vaat etmez.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/21.JKWS_.webp\" alt=\"CNBYG kontrol\u00f6r\u00fc olay tetiklemeli harmonik kay\u0131t plan\u0131n\u0131 belgeleme i\u00e7in\" \/><\/figure>\n<nav class=\"b2b-toc\" style=\"background:#f5f8fa;padding:16px 20px;border-radius:8px;margin:0 0 24px\">\n<h2 id=\"contents\" style=\"margin:42px 0 14px;scroll-margin-top:96px\">\u0130\u00e7indekiler<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"#part-1-define-the-event-question-before-enabling-triggers\">B\u00f6l\u00fcm 1. Tetikleyicileri etkinle\u015ftirmeden \u00f6nce olayla ilgili soruyu tan\u0131mlay\u0131n<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-2-choose-a-trigger-that-can-be-reviewed-later\">B\u00f6l\u00fcm 2. Daha sonra incelenebilecek bir tetikleyici se\u00e7in<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-3-keep-electrical-and-operating-clocks-together\">B\u00f6l\u00fcm 3. Elektriksel ve i\u015fletimsel zaman kay\u0131tlar\u0131n\u0131 birlikte tutun<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-4-compare-repeatable-events-at-the-same-boundary\">B\u00f6l\u00fcm 4. Ayn\u0131 s\u0131n\u0131r noktas\u0131nda tekrarlanabilir olaylar\u0131 kar\u015f\u0131la\u015ft\u0131r\u0131n<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-5-separate-event-evidence-from-a-mitigation-promise\">B\u00f6l\u00fcm 5. Olay kan\u0131tlar\u0131n\u0131 iyile\u015ftirme vaadinden ayr\u0131 tutun<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-6-send-an-event-record-package-with-the-rfq\">B\u00f6l\u00fcm 6. Olay kay\u0131t paketini RFQ ile birlikte g\u00f6nderin<\/a><\/li>\n<\/ul>\n<\/nav>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"direct-answer\">Do\u011frudan cevap<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">\u0130ncelenebilir bir tetikleyici belirleyin, elektriksel s\u0131n\u0131r noktas\u0131n\u0131 ve kay\u0131t ayarlar\u0131n\u0131 koruyun ve i\u015fletim ko\u015fulunu ayn\u0131 anda kaydedin. Ard\u0131ndan, bir proje g\u00f6r\u00fc\u015fmesinde kan\u0131t olarak de\u011ferlendirmeden \u00f6nce benzer ko\u015fullarda toplanan olaylar\u0131 kar\u015f\u0131la\u015ft\u0131r\u0131n.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-1-define-the-event-question-before-enabling-triggers\">B\u00f6l\u00fcm 1. Tetikleyicileri etkinle\u015ftirmeden \u00f6nce olayla ilgili soruyu tan\u0131mlay\u0131n<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Bir tetikleyici se\u00e7meden \u00f6nce soruyu yaz\u0131l\u0131 olarak belirleyin. Ekip, tekrarlanan bir proses ge\u00e7i\u015fini, yinelenen bir ba\u015flatma dizisini, anahtarlama de\u011fi\u015fikli\u011fini veya a\u00e7\u0131klanamayan bir alarm zaman aral\u0131\u011f\u0131n\u0131 kaydetmek isteyebilir. Bunlar\u0131n her biri, tan\u0131mlanm\u0131\u015f bir elektriksel konum ve kayd\u0131n yakalamas\u0131 beklenen olay\u0131n a\u00e7\u0131k bir tan\u0131m\u0131n\u0131 gerektirir.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Tek hat \u015femas\u0131 \u00fczerinde \u00f6l\u00e7\u00fcm cihaz\u0131n\u0131, ak\u0131m transformat\u00f6r\u00fcn\u00fc (CT), gerilim referans\u0131n\u0131 ve kapsama al\u0131nan devreleri i\u015faretleyin. Proje sorusunu ilgili konumun yan\u0131nda belirtin. Bu, yerel bir kayd\u0131n daha sonra t\u00fcm tesisin kayd\u0131ym\u0131\u015f gibi tan\u0131mlanmas\u0131n\u0131 \u00f6nler.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>\u00d6nemli:<\/strong> Bir olay dalga bi\u00e7imini temel nedenin veya bir iyile\u015ftirme sonucunun kan\u0131t\u0131 olarak de\u011ferlendirmeyin. Elektriksel s\u0131n\u0131r noktas\u0131, i\u015fletim ko\u015fulu ve proje kabul y\u00f6ntemi ayr\u0131 ayr\u0131 tan\u0131mlanmal\u0131d\u0131r (<a href=\"https:\/\/standards.ieee.org\/ieee\/519\/5892\/\" rel=\"nofollow noopener\" target=\"_blank\">IEEE 519 \u00f6zeti<\/a>).<\/p>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Olay sorusu<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Belgelenecek s\u0131n\u0131r noktas\u0131<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Saklanacak kan\u0131t<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Tekrarlanabilir proses ge\u00e7i\u015fi<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Tan\u0131mlanm\u0131\u015f proses besleyicisi<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Proses durumu, tetikleme zaman\u0131 ve kapsama al\u0131nan y\u00fck gruplar\u0131<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Anahtarlamayla ilgili g\u00f6zlem<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Se\u00e7ilen bara veya besleyici<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Anahtarlama durumu, saya\u00e7 kurulumu ve olay \u00f6ncesi\/sonras\u0131 zaman aral\u0131\u011f\u0131<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Alarm veya a\u00e7ma incelemesi<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u00dczerinde mutab\u0131k kal\u0131nan elektriksel konum<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Alarm saati, olay d\u0131\u015fa aktar\u0131m\u0131 ve i\u015fletme kayd\u0131<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-2-choose-a-trigger-that-can-be-reviewed-later\">B\u00f6l\u00fcm 2. Daha sonra incelenebilecek bir tetikleyici se\u00e7in<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Rapordan ba\u015fka bir incelemecinin anlayabilece\u011fi bir tetikleyici se\u00e7in. Tetikleyici t\u00fcr\u00fcn\u00fc, yap\u0131land\u0131r\u0131ld\u0131\u011f\u0131 \u015fekliyle e\u015fi\u011fi veya olay kural\u0131n\u0131, olay \u00f6ncesi ve sonras\u0131 s\u00fcreleri, \u00f6rnekleme veya toplula\u015ft\u0131rma ayar\u0131n\u0131 ve varsa bekleme mant\u0131\u011f\u0131n\u0131 kaydedin. Ama\u00e7 en fazla say\u0131da dosyay\u0131 toplamak de\u011fil, birbiriyle kar\u015f\u0131la\u015ft\u0131r\u0131labilecek kay\u0131tlar\u0131 toplamakt\u0131r.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Tek tetikleyici notu olarak \u201cy\u00fcksek harmonikler\u201d gibi belirsiz bir a\u00e7\u0131klama kullanmaktan ka\u00e7\u0131n\u0131n. Orijinal cihaz d\u0131\u015fa aktar\u0131m\u0131n\u0131 ve k\u0131sa bir yap\u0131land\u0131rma notunu ekleyin. Toplama d\u00f6nemi boyunca ayarlar de\u011fi\u015firse olaylar\u0131 ayr\u0131 seriler olarak etiketleyin.<\/p>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Tetikleyici kay\u0131t \u00f6\u011fesi<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">D\u0131\u015fa aktar\u0131mla birlikte saklay\u0131n<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Kullan\u0131m incelemesi<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Tetikleyici kural\u0131<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cihaz alan\u0131 veya belgelenmi\u015f olay ko\u015fulu<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Kayd\u0131n neden ba\u015flat\u0131ld\u0131\u011f\u0131n\u0131 g\u00f6sterir.<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Zaman aral\u0131\u011f\u0131<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Olay \u00f6ncesi, olay s\u0131ras\u0131 ve olay sonras\u0131 d\u00f6nem<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Benzer olaylar aras\u0131nda kar\u015f\u0131la\u015ft\u0131rma yap\u0131lmas\u0131n\u0131 sa\u011flar.<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Saya\u00e7 kurulumu<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ak\u0131m trafosu (CT) oran\u0131, gerilim referans\u0131 ve yap\u0131land\u0131rma<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Kayd\u0131n neleri i\u00e7erdi\u011fini belirler.<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yap\u0131land\u0131rma de\u011fi\u015fikli\u011fi<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ayarlar\u0131n de\u011fi\u015ftirildi\u011fi tarih ve de\u011fi\u015fiklik nedeni<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Durdurmalar\u0131n, yakalamalardan farkl\u0131 olarak birle\u015ftirilmesi.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-3-keep-electrical-and-operating-clocks-together\">B\u00f6l\u00fcm 3. Elektriksel ve i\u015fletimsel zaman kay\u0131tlar\u0131n\u0131 birlikte tutun<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Bir olay kayd\u0131 hem elektriksel zaman bilgisine hem de i\u015fletme g\u00fcnl\u00fc\u011f\u00fcne ihtiya\u00e7 duyar. Vardiyay\u0131, proses durumunu, aktif s\u00fcr\u00fcc\u00fc gruplar\u0131n\u0131, do\u011frultucular\u0131, UPS y\u00fcklerini, ba\u015flatmalar\u0131, durdurmalar\u0131, transferleri, kondansat\u00f6r anahtarlamalar\u0131n\u0131, bypass durumunu ve kaynak d\u00fczenini kaydedin. Tek ba\u015f\u0131na zaman damgas\u0131, tesisin o s\u0131rada ne yapt\u0131\u011f\u0131n\u0131 g\u00f6stermez.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/22.JKWS_.webp\" alt=\"CNBYG kontrol\u00f6r\u00fc terminal g\u00f6r\u00fcn\u00fcm\u00fc olay yakalama ba\u011flant\u0131lar\u0131n\u0131 belgeleme i\u00e7in\" \/><\/figure>\n<p style=\"margin:0 0 16px;line-height:1.7\">Mevcut ara\u00e7lar\u0131n izin verdi\u011fi \u00f6l\u00e7\u00fcde saatleri senkronize edin, ard\u0131ndan raporda bilinen belirsizlikleri belirtin. Ama\u00e7 izlenebilirlik sa\u011flamakt\u0131r; her olay\u0131n ayn\u0131 nedenden kaynakland\u0131\u011f\u0131n\u0131 iddia etmek de\u011fildir. <a href=\"https:\/\/cnbygele.com\/tr\/blog\/voltage-flicker-welding-loads-pst-measurement\/\">olay ve k\u0131rp\u0131\u015fma \u00f6l\u00e7\u00fcm ba\u011flam\u0131<\/a> makalesi, i\u015fletme durumunun neden g\u00fc\u00e7 kalitesi verilerinin yan\u0131nda yer almas\u0131 gerekti\u011fine dair ayr\u0131 bir \u00f6rnektir.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-4-compare-repeatable-events-at-the-same-boundary\">B\u00f6l\u00fcm 4. Ayn\u0131 s\u0131n\u0131r noktas\u0131nda tekrarlanabilir olaylar\u0131 kar\u015f\u0131la\u015ft\u0131r\u0131n<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Olay kay\u0131tlar\u0131n\u0131 yaln\u0131zca elektriksel konum ve \u00f6l\u00e7\u00fcm yap\u0131land\u0131rmas\u0131 biliniyorsa kar\u015f\u0131la\u015ft\u0131r\u0131n. Kay\u0131tlar\u0131 benzer proses ko\u015fullar\u0131na g\u00f6re grupland\u0131r\u0131n, ard\u0131ndan tetikleyicinin, y\u00fck durumunun ve dalga bi\u00e7imi veya ak\u0131m kan\u0131tlar\u0131n\u0131n tutarl\u0131 olup olmad\u0131\u011f\u0131n\u0131 kontrol edin. Tek bir anormal kay\u0131t \u00f6nemli olabilir, ancak benzer kan\u0131tlar elde edilene kadar m\u00fcnferit bir g\u00f6zlem olarak etiketlenmelidir.<\/p>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Kar\u015f\u0131la\u015ft\u0131rma sorusu<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Sabit tut veya a\u00e7\u0131kla<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Varsay\u0131mda bulunmaktan ka\u00e7\u0131n\u0131n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ayn\u0131 s\u0131n\u0131r noktas\u0131 m\u0131 kullan\u0131ld\u0131?<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Saya\u00e7, ak\u0131m trafosu (CT) ve gerilim referans\u0131<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u0130ki fiderin ayn\u0131 y\u00fck bile\u015fimini tan\u0131mlad\u0131\u011f\u0131.<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u0130\u015fletme durumu benzer miydi?<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Proses ko\u015fulu ve ana y\u00fckler<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Her kayd\u0131rman\u0131n e\u015fit oldu\u011fu.<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Tetikleme kural\u0131 de\u011fi\u015fti mi?<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yap\u0131land\u0131rma ve zaman penceresi<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">T\u00fcm yakalamalar\u0131n ayn\u0131 \u015fekilde ba\u015flat\u0131ld\u0131\u011f\u0131.<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ba\u015fka bir olay e\u015fzamanl\u0131 m\u0131yd\u0131?<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Anahtar, kaynak veya bak\u0131m notu<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Harmonik ak\u0131m, her g\u00f6zlemi a\u00e7\u0131klad\u0131\u011f\u0131n\u0131 g\u00f6steriyor.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\">Daha geni\u015f bir koleksiyon kontrol listesi i\u00e7in bak\u0131n\u0131z <a href=\"https:\/\/cnbygele.com\/tr\/blog\/power-quality-metering-before-apf-svg-rfq\/\">RFQ \u00f6ncesi g\u00fc\u00e7 kalitesi \u00f6l\u00e7\u00fcm\u00fc<\/a>. Bu kan\u0131tlar\u0131 d\u00fczenler ancak bir tesis durumu onaylamaz.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-5-separate-event-evidence-from-a-mitigation-promise\">B\u00f6l\u00fcm 5. Olay kan\u0131tlar\u0131n\u0131 iyile\u015ftirme vaadinden ayr\u0131 tutun<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Olay verileri, inceleme kapsam\u0131n\u0131 tan\u0131mlamaya yard\u0131mc\u0131 olabilir, ancak ekipman\u0131 kendi ba\u015f\u0131na se\u00e7mez. AHF\/APF tart\u0131\u015fmas\u0131ndan \u00f6nce, harmonik-ak\u0131m hedefini, ba\u011flant\u0131 noktas\u0131n\u0131, CT d\u00fczenlemesini, temsili y\u00fck kayd\u0131n\u0131, koruma koordinasyonunu, kurulum k\u0131s\u0131tlamalar\u0131n\u0131, kablo g\u00fczergah\u0131n\u0131, so\u011futmay\u0131, ileti\u015fimi ve kabul y\u00f6ntemini belirleyin.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">The <a href=\"https:\/\/cnbygele.com\/tr\/product\/ahf-active-harmonic-filter-harmonic-control\/\">AHF Aktif Harmonik Filtre \u00fcr\u00fcn ba\u011flam\u0131<\/a> Sayfa, tan\u0131mlanm\u0131\u015f bir harmonik-ak\u0131m sorusu i\u00e7in ba\u015flang\u0131\u00e7 noktas\u0131d\u0131r. Bir olay\u0131 kald\u0131rmay\u0131, bir trip'i \u00f6nlemeyi veya belirli bir i\u015fletim sonucunu garanti etmez.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/23.JKG2B.webp\" alt=\"Olay kayd\u0131 incelemesinden sonra \u00fcr\u00fcn ba\u011flam\u0131 olarak g\u00f6sterilen CNBYG kontrol\u00f6r\u00fc\" \/><\/figure>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-6-send-an-event-record-package-with-the-rfq\">B\u00f6l\u00fcm 6. Olay kay\u0131t paketini RFQ ile birlikte g\u00f6nderin<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Olay kan\u0131tlar\u0131n\u0131, bir inceleyicinin tesis durumu ile ili\u015fkilendirebilece\u011fi \u015fekilde paketleyin. Hem orijinal d\u0131\u015fa aktar\u0131mlar\u0131 hem de bunlar\u0131 yorumlamak i\u00e7in gereken notlar\u0131 dahil edin.<\/p>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Al\u0131c\u0131 sa\u011flamal\u0131d\u0131r<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Neden \u00f6nemli<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Tek hat diyagram\u0131 ve beyan edilen nominal sistem bilgisi<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Elektrik s\u0131n\u0131r\u0131n\u0131 ve besleme ba\u011flam\u0131n\u0131 tan\u0131mlar.<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Saya\u00e7, ak\u0131m trafosu (CT) ve gerilim referans konumlar\u0131<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ger\u00e7ek \u00f6l\u00e7\u00fcm konumunu tan\u0131mlar.<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Tetikleme kural\u0131, ayarlar ve olay d\u0131\u015fa aktar\u0131mlar\u0131<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yakalama y\u00f6nteminin incelenebilir olmas\u0131n\u0131 sa\u011flar.<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Saat referans\u0131 ve i\u015fletim durumu g\u00fcnl\u00fc\u011f\u00fc<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Olaylar\u0131 tesis i\u015fletmesiyle ili\u015fkilendirir.<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Y\u00fck envanteri ve mevcut ekipman<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Her yakalama etraf\u0131ndaki ba\u011flam\u0131 tan\u0131mlar.<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Koruma, kurulum s\u0131n\u0131rlar\u0131 ve kabul gereksinimleri<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Entegrasyon ve proje s\u0131n\u0131rlar\u0131n\u0131 tan\u0131mlar.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\">CNBYG, olay kay\u0131tlar\u0131 belirli bir harmonik ak\u0131m hedefi olu\u015fturduktan sonra \u00fcr\u00fcn hatt\u0131 uyumunu tart\u0131\u015fabilir. Kullan\u0131m <a href=\"https:\/\/cnbygele.com\/tr\/contact-us\/\">olay kay\u0131t paketi<\/a> bu konu\u015fmay\u0131 ba\u015flatmak i\u00e7in; bu k\u0131lavuz k\u00f6k neden \u00e7al\u0131\u015fmas\u0131n\u0131n yerini alamaz veya proje sonucu vaat edemez.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"frequently-asked-questions\">S\u0131k sorulan sorular<\/h2>\n<h3 style=\"margin:28px 0 12px\">Olay tetiklemeli harmonik kayd\u0131 nedir?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Belgelendirilmi\u015f bir olay durumu ger\u00e7ekle\u015fti\u011finde elektriksel kay\u0131tlar\u0131n yakalanmas\u0131 y\u00f6ntemidir. Kay\u0131t, tetikleme kural\u0131n\u0131, elektriksel konumu, zaman penceresini, saya\u00e7 ayar\u0131n\u0131 ve \u00e7al\u0131\u015fma durumunu i\u00e7ermelidir.<\/p>\n<h3 style=\"margin:28px 0 12px\">Bir kayd\u0131 tetiklemeli ne olmal\u0131?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">\u0130nceleme sorusuna uygun ve daha sonra belgelendirilebilecek bir tetikleyici se\u00e7in. Orijinal cihaz ayar\u0131n\u0131, kay\u0131t penceresini ve herhangi bir yap\u0131land\u0131rma de\u011fi\u015fikli\u011fini kaydedin.<\/p>\n<h3 style=\"margin:28px 0 12px\">Bir olay bir k\u00f6k nedeni kan\u0131tlar m\u0131?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Hay\u0131r. Bir kay\u0131t bir g\u00f6zlemi tan\u0131mlayabilir, ancak neden atamak veya hafifletici \u00f6nlemi se\u00e7meden \u00f6nce kar\u015f\u0131la\u015ft\u0131rmal\u0131 kay\u0131tlar, \u00e7al\u0131\u015fma ba\u011flam\u0131 ve proje incelemesi gereklidir.<\/p>\n<h3 style=\"margin:28px 0 12px\">Neden bir olayla birlikte \u00e7al\u0131\u015fma durumunu kaydetmeli?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Aktif s\u00fcre\u00e7, y\u00fck gruplar\u0131, ba\u015flatmalar, anahtar de\u011fi\u015fiklikleri ve kaynak d\u00fczeni, elektriksel kayd\u0131n temsil etti\u011fini de\u011fi\u015ftirebilir. \u00c7al\u0131\u015fma g\u00fcnl\u00fc\u011f\u00fc kar\u015f\u0131la\u015ft\u0131rmalar\u0131 anlaml\u0131 k\u0131lar.<\/p>\n<h3 style=\"margin:28px 0 12px\">Olay verileri bir APF se\u00e7ebilir mi?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Hay\u0131r. Bir AHF\/APF incelemesi yine tan\u0131mlanm\u0131\u015f bir harmonik ak\u0131m hedefi, ba\u011flant\u0131 noktas\u0131, temsil edici y\u00fck verisi, entegrasyon k\u0131s\u0131tlamalar\u0131 ve kabul kapsam\u0131 gerektirir.<\/p>\n<h3 style=\"margin:28px 0 12px\">Olay tabanl\u0131 RFQ paketine ne girer?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Tek hat diyagram\u0131, \u00f6l\u00e7\u00fcm kurulumu, tetikleme ayarlar\u0131, olay d\u0131\u015fa aktar\u0131m\u0131, zaman ve \u00e7al\u0131\u015fma g\u00fcnl\u00fckleri, y\u00fck envanteri, mevcut ekipman detaylar\u0131 ve kurulum k\u0131s\u0131tlamalar\u0131n\u0131 g\u00f6nderin.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"references\">Kaynak\u00e7a<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/standards.ieee.org\/ieee\/519\/5892\/\" rel=\"nofollow noopener\" target=\"_blank\">Harmonik kontrol ba\u011flam\u0131 i\u00e7in IEEE 519 kayna\u011f\u0131<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/www.nema.org\/standards\/view\/motors-and-generators\" rel=\"nofollow noopener\" target=\"_blank\">Motor sistemi ba\u011flam\u0131 i\u00e7in NEMA MG 1 referans\u0131<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/www.energy.gov\/cmei\/ito\/industrial-technologies-office\" rel=\"nofollow noopener\" target=\"_blank\">DOE End\u00fcstriyel Teknolojiler Ofisi kaynaklar\u0131<\/a><\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Intermittent-load investigations often need more than a long average trend. Event-triggered harmonic logging can preserve what happened at a named electrical boundary when a defined condition occurred, provided that the trigger settings, clock, meter setup, and operating state are saved with the record. For broader planning context, start with the power quality system guides. This [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":1632,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-2365","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":8}},"acf":[],"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/posts\/2365","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/comments?post=2365"}],"version-history":[{"count":1,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/posts\/2365\/revisions"}],"predecessor-version":[{"id":2513,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/posts\/2365\/revisions\/2513"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/media\/1632"}],"wp:attachment":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/media?parent=2365"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/categories?post=2365"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/tags?post=2365"}],"curies":[{"name":"Naber","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}