{"id":2443,"date":"2026-08-20T07:00:00","date_gmt":"2026-08-19T23:00:00","guid":{"rendered":"https:\/\/cnbygele.com\/?p=2443"},"modified":"2026-08-24T17:23:12","modified_gmt":"2026-08-24T09:23:12","slug":"what-are-capacitor-banks","status":"publish","type":"post","link":"https:\/\/cnbygele.com\/tr\/blog\/what-are-capacitor-banks\/","title":{"rendered":"Kondansat\u00f6r Bankalar\u0131 Nedir?"},"content":{"rendered":"<div class=\"b2b-article\">\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Kondansat\u00f6r bankalar\u0131<\/strong> hedef bir anma gerilimine ve reaktif g\u00fc\u00e7 (kvar) \u00e7\u0131k\u0131\u015f\u0131na ula\u015fmak i\u00e7in seri, paralel veya her ikisi birden ba\u011flanm\u0131\u015f birden fazla g\u00fc\u00e7 kondansat\u00f6r\u00fc \u00fcnitesinden olu\u015fan d\u00fczenlemelerdir. Tesisler genellikle yerel reaktif g\u00fc\u00e7 sa\u011flamak ve g\u00fc\u00e7 fakt\u00f6r\u00fcn\u00fc iyile\u015ftirmek i\u00e7in bu d\u00fczenlemeyi bir bara veya y\u00fcke paralel (\u015f\u00f6nt) olarak ba\u011flar.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Bu k\u0131lavuz tesis rol\u00fcn\u00fc, \u00f6nc\u00fc ak\u0131mlar\u0131n end\u00fcktif motorlar\u0131 nas\u0131l telafi etti\u011fini, \u00fcst d\u00fczey tipleri, yerle\u015ftirme se\u00e7eneklerini ve harmoniklerin d\u00fcz bir kondansat\u00f6r grubunu ne zaman yanl\u0131\u015f ilk hamle haline getirdi\u011fini kapsar. Kvar boyutland\u0131rma matemati\u011fi i\u00e7in, ayr\u0131 sayfam\u0131z\u0131 a\u00e7\u0131n <a href=\"https:\/\/cnbygele.com\/tr\/blog\/capacitor-bank-sizing-for-power-factor-correction\/\">g\u00fc\u00e7 fakt\u00f6r\u00fc d\u00fczeltmesi i\u00e7in kondansat\u00f6r bankas\u0131 boyutland\u0131rmas\u0131<\/a> makale, bu sayfay\u0131 bir hesap makinesi olarak ele almak yerine.<\/p>\n<nav class=\"b2b-toc\" style=\"background:#f5f8fa;padding:16px 20px;border-radius:8px;margin:0 0 24px\">\n<h2 id=\"contents\" style=\"margin:42px 0 14px;scroll-margin-top:96px\">\u0130\u00e7indekiler<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"#what-a-capacitor-bank-is\">Kondansat\u00f6r Bankas\u0131 Nedir<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#the-role-of-capacitor-banks-in-a-plant-electrical-system\">Bir Tesis Elektrik Sisteminde Kondansat\u00f6r Bankalar\u0131n\u0131n Rol\u00fc<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#how-capacitor-banks-supply-reactive-power\">Kondansat\u00f6r Bankalar\u0131n\u0131n Reaktif G\u00fc\u00e7 Sa\u011flama Y\u00f6ntemi<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#common-capacitor-bank-types-at-a-high-level\">Genel Hatlar\u0131yla Yayg\u0131n Kondansat\u00f6r Bankas\u0131 T\u00fcrleri<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#where-capacitor-banks-sit-in-a-plant\">Kondansat\u00f6r Bankalar\u0131n\u0131n Bir Tesiste Konumland\u0131\u011f\u0131 Yerler<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#limits-harmonics-and-when-a-bank-is-the-wrong-first-move\">S\u0131n\u0131rlar, Harmonikler ve Bir Bankan\u0131n Neden Yanl\u0131\u015f \u0130lk Hamle Oldu\u011fu<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#choosing-lv-capacitor-hardware-and-next-steps\">AG Kondansat\u00f6r Donan\u0131m\u0131 Se\u00e7imi ve Sonraki Ad\u0131mlar<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#faq\">SSS<\/a><\/li>\n<\/ul>\n<\/nav>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"what-a-capacitor-bank-is\">Kondansat\u00f6r Bankas\u0131 Nedir<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Kondansat\u00f6r grubu, iki terminalli tek bir kutu de\u011fildir; voltaj kapasitesi ve kvar de\u011ferinin uygulaman\u0131n ihtiya\u00e7 duydu\u011fu seviyeye ula\u015fmas\u0131 i\u00e7in d\u00fczenlenmi\u015f, m\u00fchendislik \u00fcr\u00fcn\u00fc bir kondansat\u00f6r \u00fcniteleri toplulu\u011fudur.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Her \u00fcnite, bir dielaktrikle ayr\u0131lm\u0131\u015f iletkenler aras\u0131ndaki bir elektrik alan\u0131nda enerji depolar. Seri diziler, tertibat\u0131n dayanabilece\u011fi gerilimi y\u00fckseltir. Paralel yollar toplam reaktif g\u00fcc\u00fc art\u0131r\u0131r.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Tamamlanan banka a\u00e7\u0131k tip rafta, metal mahfazada, direk tip \u015fasi \u00fczerinde veya al\u00e7ak gerilim kompenzasyon panosunda bulunabilir.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Bitki dilinde de duyacaks\u0131n\u0131z <strong>\u015f\u00f6nt kondansat\u00f6r grubu<\/strong> veya g\u00fc\u00e7 fakt\u00f6r\u00fc kondansat\u00f6r grubu. Bir <strong>\u015f\u00f6nt ba\u011flant\u0131<\/strong> seri ba\u011flanan bankalar, uzun bir iletim devresiyle ayn\u0131 hizada yer alarak farkl\u0131 bir \u015febeke problemini \u00e7\u00f6zer ve bu AG tesis tart\u0131\u015fmas\u0131n\u0131n d\u0131\u015f\u0131nda kal\u0131r. (Not: Metnin ba\u011flam\u0131na g\u00f6re \"bank\" kelimesi elektrik sistemlerindeki kondansat\u00f6r\/kapasit\u00f6r bankas\u0131 anlam\u0131na gelmektedir.).<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"Fabrika \u015falt cihaz\u0131n\u0131n yan\u0131nda kademelendirilmi\u015f end\u00fcstriyel al\u00e7ak gerilim kondansat\u00f6r bankas\u0131 mod\u00fclleri\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/08\/what-are-capacitor-banks-featured-1.webp\" \/><\/figure>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"the-role-of-capacitor-banks-in-a-plant-electrical-system\">Bir Tesis Elektrik Sisteminde Kondansat\u00f6r Bankalar\u0131n\u0131n Rol\u00fc<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Kondansat\u00f6r bankalar\u0131 tesislerde esas olarak \u015fu ama\u00e7la bulunur: <strong>kondansat\u00f6r bankas\u0131 g\u00fc\u00e7 fakt\u00f6r\u00fc d\u00fczeltmesi<\/strong>End\u00fcktif ekipman\u0131n yukar\u0131 ak\u0131\u015f trafolar\u0131ndan, kablolardan ve \u015febeke besleyicilerinden o kadar fazla end\u00fcktif ak\u0131m \u00e7ekmemesi i\u00e7in reaktif g\u00fcc\u00fc yerel olarak sa\u011flarlar.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Motorlar, transformat\u00f6rler ve bir\u00e7ok ayd\u0131nlatma balast\u0131 m\u0131knat\u0131slanma ak\u0131m\u0131na ihtiya\u00e7 duyar. Bu ak\u0131m \u00e7ok az faydal\u0131 mekanik veya termal i\u015f yapar, ancak yine de g\u00f6r\u00fcn\u00fcr g\u00fcce (kVA) d\u00e2hil olur. G\u00f6r\u00fcn\u00fcr g\u00fcce b\u00f6l\u00fcnm\u00fc\u015f ger\u00e7ek g\u00fc\u00e7 olan g\u00fc\u00e7 fakt\u00f6r\u00fc, bu geciken reaktif talep b\u00fcy\u00fck oldu\u011funda d\u00fc\u015fer.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Pek \u00e7ok ABD elektrik da\u011f\u0131t\u0131m \u015firketi, tesis g\u00fc\u00e7 fakt\u00f6r\u00fc yakla\u015f\u0131k 0,95'in alt\u0131na d\u00fc\u015ft\u00fc\u011f\u00fcnde ek \u00fccretler talep edebilir. Bir kalem cezas\u0131 olmasa bile, fazladan ak\u0131m yine de tesis ekipman\u0131n\u0131 zorlar.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Do\u011fru \u015fekilde uygulanm\u0131\u015f bir kondansat\u00f6r grubu bu y\u00fcklerin yak\u0131n\u0131na \u00f6nc\u00fc reaktif destek enjekte etti\u011finde, elektrik da\u011f\u0131t\u0131m \u015firketi ve tesisin ana transformat\u00f6rleri daha k\u00fc\u00e7\u00fck bir reaktif bile\u015fen g\u00f6r\u00fcr. Ayn\u0131 kilovatl\u0131k proses y\u00fck\u00fc i\u00e7in besleyici ak\u0131m\u0131 d\u00fc\u015febilir ve bo\u015fa \u00e7\u0131kan transformat\u00f6r kapasitesi \u00fcretim art\u0131\u015f\u0131 i\u00e7in kullan\u0131labilir hale gelir.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Tazminat\u0131n kendisine dair daha geni\u015f bir fikre hala ihtiyac\u0131n\u0131z varsa, \u015furadan ba\u015flay\u0131n: <a href=\"https:\/\/cnbygele.com\/tr\/blog\/what-is-reactive-power-compensation-key-concepts-explained\/\">Reaktif g\u00fc\u00e7 kompansazyonu<\/a>, ard\u0131ndan bankan\u0131n-donan\u0131m-olarak g\u00f6r\u00fcn\u00fcm\u00fc i\u00e7in buraya d\u00f6n\u00fcn.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"how-capacitor-banks-supply-reactive-power\">Kondansat\u00f6r Bankalar\u0131n\u0131n Reaktif G\u00fc\u00e7 Sa\u011flama Y\u00f6ntemi<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Kondansat\u00f6r gruplar\u0131, end\u00fcktif y\u00fcklerin talep etti\u011fi geri ak\u0131m\u0131 dengeleyen ileri y\u00f6nl\u00fc bir ak\u0131m \u00e7ekerek reaktif g\u00fc\u00e7 sa\u011flar.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Bir AC baras\u0131nda, ideal bir kondansat\u00f6r\u00fcn ak\u0131m\u0131 u\u00e7 geriliminden yakla\u015f\u0131k doksan derece \u00f6ndedir. Bir end\u00fcksiyon motorunun m\u0131knat\u0131slanma ak\u0131m\u0131 gerilimin gerisindedir. Kondansat\u00f6r\u00fc motor besleyicisine veya ortak bir baraya \u015f\u00f6nt olarak ba\u011flay\u0131n; b\u00f6ylece iki reaktif ak\u0131m k\u0131smen birbirini g\u00f6t\u00fcr\u00fcr.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Ger\u00e7ek g\u00fc\u00e7 yine \u015file iletiliyor. \u201cYana do\u011fru\u201d reaktif al\u0131\u015fveri\u015f, t\u00fcm\u00fcyle \u015febeke jenerat\u00f6r\u00fcnden ta\u015f\u0131nmak yerine, motor ile kondansat\u00f6r aras\u0131nda daha yerel olarak ger\u00e7ekle\u015fir.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Reaktif g\u00fcc\u00fc, manyetik alanlar\u0131 canl\u0131 tutan ak\u0131m k\u0131sm\u0131 olarak d\u00fc\u015f\u00fcn\u00fcn. Batarya, bu al\u0131\u015fveri\u015f i\u00e7in yerel bir rezervuar haline gelir. Kontrol\u00f6rler ve \u015falterler, tesis y\u00fck\u00fc de\u011fi\u015ftik\u00e7e bu rezervuar\u0131n ka\u00e7 kademesinin devreye al\u0131naca\u011f\u0131na karar verir.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Derin kvar se\u00e7imi, tan\u03c6 tablolar\u0131 ve hedef g\u00fc\u00e7 fakt\u00f6r\u00fc (PF) \u00e7al\u0131\u015fma sayfalar\u0131 yukar\u0131da ba\u011flant\u0131s\u0131 verilen canl\u0131 boyutland\u0131rma k\u0131lavuzunda yer almal\u0131d\u0131r. Bu b\u00f6l\u00fcm, sonraki tip ve risk se\u00e7imlerinin mant\u0131kl\u0131 olmas\u0131 i\u00e7in yaln\u0131zca mekanizmay\u0131 kilitlemektedir.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"\u015e\u00f6nt bankas\u0131 olarak bir raf \u00fczerine monte edilmi\u015f mod\u00fcler kondansat\u00f6r \u00fcniteleri\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/08\/what-are-capacitor-banks-assembly-1.webp\" \/><\/figure>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"common-capacitor-bank-types-at-a-high-level\">Genel Hatlar\u0131yla Yayg\u0131n Kondansat\u00f6r Bankas\u0131 T\u00fcrleri<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">\u00c7o\u011fu proje g\u00f6r\u00fc\u015fmesinde kondansat\u00f6r bankalar\u0131 marka logolar\u0131na g\u00f6re de\u011fil, nas\u0131l kontrol edildiklerine ve harmonik detuning i\u00e7erip i\u00e7ermediklerine g\u00f6re s\u0131n\u0131fland\u0131r\u0131l\u0131r.<\/p>\n<div class=\"b2b-table-scroll\" role=\"region\" aria-label=\"Kayd\u0131r\u0131labilir veri tablosu\" tabindex=\"0\" style=\"width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 18px\">\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">T\u00fcr<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Ald\u0131\u011f\u0131n \u015fey<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Standart kal\u0131p<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Sabit kondansat\u00f6r grubu<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Devre canl\u0131 oldu\u011fu s\u00fcrece enerjili kalan bir set kvar blo\u011fu<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Nadiren dalgalanma g\u00f6steren kararl\u0131 end\u00fcktif y\u00fck<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Otomatik kompanzasyon panosu<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">G\u00fc\u00e7 fakt\u00f6r\u00fc veya kvar kontrol cihaz\u0131 taraf\u0131ndan anahtarlanan \u00e7oklu kademeler<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Vardiyalar, parti i\u015flemleri veya g\u00fcnl\u00fck y\u00fck profilleri<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Filtreli kompanzasyon panosu<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yayg\u0131n harmoniklerin alt\u0131na rezonans \u00e7eken seri reakt\u00f6rl\u00fc kondansat\u00f6r kademeleri<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">VFD'ler, do\u011frultucular veya di\u011fer do\u011frusal olmayan y\u00fcklere sahip tesisler<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"margin:0 0 16px;line-height:1.7\">Al\u00e7ak gerilim veya orta gerilim projelerindeki (a\u00e7\u0131k havada kurulan raflar, metal mahfazal\u0131 d\u00fczenekler, direk tipi sehpalar veya mobil r\u00f6morklar) ambalaj etiketleri, farkl\u0131 bir elektriksel ama\u00e7tan ziyade muhafaza ve montaj bi\u00e7imini tan\u0131mlar. Al\u00e7ak gerilim end\u00fcstriyel sahalar\u0131, kontakt\u00f6rl\u00fc veya yar\u0131 iletken anahtarlarla donat\u0131lm\u0131\u015f ve bazen entegre edilmi\u015f kabin tipi kademeler fikrini daha s\u0131kl\u0131kla kar\u015f\u0131lar. <a href=\"https:\/\/cnbygele.com\/tr\/intelligent-capacitor\/\">ak\u0131ll\u0131 kondansat\u00f6r<\/a> mod\u00fcller.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Orta gerilim raflar\u0131ndaki koruma tarz\u0131 (dahili sigortal\u0131, harici sigortal\u0131 veya sigortas\u0131z yap\u0131lar) bak\u0131m ve ar\u0131za davran\u0131\u015f\u0131 a\u00e7\u0131s\u0131ndan \u00f6nemlidir. Ancak bu durum, okuyucunun ilk sorusunu de\u011fi\u015ftirmez: Bu sabit bir kondansat\u00f6r grubu mu, otomatik bir kondansat\u00f6r grubu mu yoksa reakt\u00f6rl\u00fc (detuned) bir kondansat\u00f6r grubu mu?<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"Bir tesis MCC&#039;sinin yan\u0131nda kondansat\u00f6r kademeli Al\u00e7ak Gerilim kompansazyon panosu\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/08\/what-are-capacitor-banks-placement-1.webp\" \/><\/figure>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"where-capacitor-banks-sit-in-a-plant\">Kondansat\u00f6r Bankalar\u0131n\u0131n Bir Tesiste Konumland\u0131\u011f\u0131 Yerler<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Kondansat\u00f6r banklar\u0131, reaktif g\u00fc\u00e7 sorununun donan\u0131m\u0131 hakl\u0131 \u00e7\u0131karacak kadar yo\u011funla\u015ft\u0131\u011f\u0131 ve anahtarlaman\u0131n hassas cihazlar\u0131 \u015fa\u015f\u0131rtmayaca\u011f\u0131 yerlerde bulunur.<\/p>\n<div class=\"b2b-table-scroll\" role=\"region\" aria-label=\"Kayd\u0131r\u0131labilir veri tablosu\" tabindex=\"0\" style=\"width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 18px\">\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Yerle\u015ftirme<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Ba\u011flant\u0131 fikri<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">G\u00fc\u00e7<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Dikkat et<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Merkezi<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ana gelen sigorta kutusunun veya ana AG baras\u0131n\u0131n yak\u0131n\u0131nda<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Tek paket, tek kontrolc\u00fc, tek bir sat\u0131rda g\u00f6rmesi kolay<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Uzak y\u00fck merkezlerini ka\u00e7\u0131rabilir; daha b\u00fcy\u00fck ad\u0131mlar t\u00fcm baray\u0131 sallayabilir<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Grup \/ merkeziyetsiz<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Motor gruplar\u0131n\u0131 besleyen da\u011f\u0131t\u0131m panolar\u0131nda<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Reaktif talebi, onu olu\u015fturan y\u00fcklere daha yak\u0131n bir \u015fekilde kar\u015f\u0131lar<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Bak\u0131m ve koordinasyon gerektiren daha fazla panel<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Yerel<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">B\u00fcy\u00fck bir kompres\u00f6rde, de\u011firmende veya di\u011fer bask\u0131n end\u00fcktif makinede<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">En b\u00fcy\u00fck sorun kayna\u011f\u0131n\u0131 minimum kaynak ak\u0131\u015f\u0131yla d\u00fczeltir<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Bir\u00e7ok k\u00fc\u00e7\u00fck banka, her motor kendi motoruna sahip olursa ek maliyet ekler<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"margin:0 0 16px;line-height:1.7\">Sat\u0131n alma ekipleri, teklif basit g\u00f6r\u00fcnd\u00fc\u011f\u00fc i\u00e7in genellikle merkezi olarak ba\u015flar. S\u00fcre\u00e7 m\u00fchendisleri bazen ana baran\u0131n hi\u00e7bir zaman bu m\u0131knat\u0131slanma ak\u0131m\u0131n\u0131 ta\u015f\u0131mamas\u0131 i\u00e7in en b\u00fcy\u00fck motorlarda yerel bankalar\u0131 tercih ederler.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Karma tesisler her ikisini de kullan\u0131r: m\u00fctevaz\u0131 bir ana kademe art\u0131 birka\u00e7 a\u011f\u0131r makinede yerel kompanzasyon. Do\u011fru harita evrensel bir slogana de\u011fil, \u00f6l\u00e7\u00fclen y\u00fck profillerine ba\u011fl\u0131d\u0131r.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"limits-harmonics-and-when-a-bank-is-the-wrong-first-move\">S\u0131n\u0131rlar, Harmonikler ve Bir Bankan\u0131n Neden Yanl\u0131\u015f \u0130lk Hamle Oldu\u011fu<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Kondansat\u00f6r grubu, anahtarlama ge\u00e7i\u015fleri veya paralel durumunda ters tepebilir. <strong>harmonik rezonans<\/strong> do\u011frusal olmayan y\u00fckler dielektri\u011fi, sigortalar\u0131 ve yak\u0131ndaki s\u00fcr\u00fcc\u00fcleri a\u015f\u0131r\u0131 y\u00fckler.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Bir kondansat\u00f6r bank\u0131n\u0131 devreye almak basit bir olay de\u011fildir. Kapasitans sistem end\u00fcktans\u0131 ile kar\u015f\u0131la\u015ft\u0131\u011f\u0131nda inrush (ani kalk\u0131\u015f) ak\u0131mlar\u0131 ve gerilim bozulmalar\u0131 ortaya \u00e7\u0131kar. S\u0131rt s\u0131rta (back-to-back) anahtarlama\u2014ayn\u0131 bara \u00fczerinde h\u00e2lihaz\u0131rda ba\u015fka bir bank devremedeyken bir di\u011ferini devreye sokmak\u2014daha da \u015fiddetli olabilir.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Bu stresi azaltmak i\u00e7in \u00f6zel olarak kontrol\u00f6rler, \u00f6n ekleme empedans\u0131 veya s\u0131f\u0131r ge\u00e7i\u015fli anahtarlama mevcuttur.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Harmonikler hik\u00e2yeyi daha da de\u011fi\u015ftirir. Do\u011frusal olmayan y\u00fckler (de\u011fi\u015fken frekansl\u0131 s\u00fcr\u00fcc\u00fcler, kaynak makineleri, kesintisiz g\u00fc\u00e7 kayna\u011f\u0131 \u00f6n u\u00e7lar\u0131) 60 Hz'in katlar\u0131nda ak\u0131mlar enjekte eder. Kapasitif empedans frekans artt\u0131k\u00e7a d\u00fc\u015fer, bu nedenle bu ak\u0131mlar grubu tercih eder.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Banka ve besleme end\u00fcktans\u0131 karakteristik bir harmonik (genellikle 5. veya 7.) civar\u0131nda rezonansa girerse, voltaj bozulmas\u0131 artabilir, sigortalar a\u015f\u0131r\u0131 \u0131s\u0131nabilir ve kondansat\u00f6rler erken ar\u0131zalanabilir.<\/p>\n<blockquote>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Sahadan:<\/strong> Profesyonel forumlardaki tesis tart\u0131\u015fmalar\u0131, y\u00fcksek sesli u\u011fultu \u00fcreten, reakt\u00f6rleri veya kondansat\u00f6rleri a\u015f\u0131r\u0131 \u0131s\u0131nd\u0131ran ve sigortalar\u0131 att\u0131ran \u2013bazen operat\u00f6rlerin \u201cyang\u0131n korkusuyla\u201d ekipman\u0131 kapal\u0131 tutmas\u0131na neden olacak kadar \u015fiddetli olan\u2013 otomatik g\u00fc\u00e7 fakt\u00f6r\u00fc (PF) kademelerini tan\u0131mlamaktad\u0131r. Bu ifade, g\u00fc\u00e7 fakt\u00f6r\u00fc d\u00fczeltmesinden tamamen vazge\u00e7mek i\u00e7in bir neden de\u011fil, rezonans ve do\u011frusal olmayan y\u00fckler hakk\u0131nda bir uyar\u0131d\u0131r.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>\u00d6nemli:<\/strong> Fatura \u00f6zetinde yer alan kompanzasyon g\u00fc\u00e7 fakt\u00f6r\u00fc d\u00fc\u015f\u00fck g\u00f6r\u00fcn\u00fcyor diye, S\u00fcr\u00fcc\u00fc (VFD) a\u011f\u0131rl\u0131kl\u0131 bir baradaki sade, ayars\u0131z bir kondansat\u00f6r grubunu zarars\u0131z olarak de\u011ferlendirmeyin; voltaj ve ak\u0131m bozulmas\u0131n\u0131 \u00f6l\u00e7\u00fcn, rezonans riskini inceleyin ve bir <a href=\"https:\/\/cnbygele.com\/tr\/product\/cksg-series-low-voltage-series-reactors\/\">seri reakt\u00f6r<\/a> kondansat\u00f6rlerle \u2014veya ba\u015fka bir reaktif g\u00fc\u00e7 teknolojisiyle\u2014 kademe eklemeden \u00f6nce. <a href=\"https:\/\/ipqdf.com\/pq-info\/harmonics\/harmonics-and-power-factor-capacitors-understanding-failure-resonance-and-the-filter-solution\/\" rel=\"nofollow noopener\" target=\"_blank\">IPQDF harmonikleri ve g\u00fc\u00e7 fakt\u00f6r\u00fc kondansat\u00f6rleri<\/a><\/p>\n<\/blockquote>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"End\u00fcstriyel bir panoda detune kondansat\u00f6r ve seri reakt\u00f6r ba\u011flam\u0131\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/08\/what-are-capacitor-banks-detuned-1.webp\" \/><\/figure>\n<p style=\"margin:0 0 16px;line-height:1.7\">Y\u00fckler h\u0131zla sal\u0131nd\u0131\u011f\u0131nda, \u00e7ift y\u00f6nl\u00fc kompanzasyon gerekti\u011finde veya harmonik spektrumlar\u0131 s\u00fcrekli de\u011fi\u015fti\u011finde, SVG gibi elektronik tabanl\u0131 se\u00e7enekler ba\u015fka bir kondansazm ad\u0131m\u0131 yerine daha uygun olabilir. Kondansat\u00f6r kademesi, yeterince temiz bir \u015febekede kararl\u0131 end\u00fcktif reaktif g\u00fc\u00e7 talebi i\u00e7in g\u00fc\u00e7l\u00fc ve ekonomik bir ara\u00e7 olmaya devam etmektedir; evrensel bir varsay\u0131lan de\u011fildir.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"choosing-lv-capacitor-hardware-and-next-steps\">AG Kondansat\u00f6r Donan\u0131m\u0131 Se\u00e7imi ve Sonraki Ad\u0131mlar<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Al\u00e7ak gerilim tesis montajlar\u0131 i\u00e7in, kan\u0131tlanm\u0131\u015f \u015f\u00f6nt kondansat\u00f6r yap\u0131 ta\u015flar\u0131 ve kontroll\u00fc anahtarlama ile ba\u015flay\u0131n, ard\u0131ndan kvar toplamlar\u0131n\u0131 kesinle\u015ftirmeden \u00f6nce boyutland\u0131rma makalesini a\u00e7\u0131n.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\"><a href=\"https:\/\/cnbygele.com\/tr\/reactive-power-compensator\/\">CNBYG reaktif g\u00fc\u00e7 kompanzasyon merkezi<\/a> AG panosunda genellikle bir arada bulunan par\u00e7alar\u0131 grupland\u0131r\u0131r: \u015f\u00f6nt kondansat\u00f6r \u00fcniteleri, ak\u0131ll\u0131 kondansat\u00f6r mod\u00fclleri, seri reakt\u00f6rler, kontrol\u00f6rler ve anahtarlama aksesuarlar\u0131. <a href=\"https:\/\/cnbygele.com\/tr\/product\/by81-series-intelligent-capacitors\/\">BY81 serisi ak\u0131ll\u0131 kondansat\u00f6rler<\/a> \u00d6l\u00e7\u00fcm ve kontrol\u00fc senkronize s\u0131f\u0131r ge\u00e7i\u015fli anahtarlama ile birle\u015ftirerek, ad\u0131mlar\u0131n saf bir kontakt\u00f6r \u00e7arpmas\u0131n\u0131n kontrols\u00fcz ani ak\u0131m\u0131 olmaks\u0131z\u0131n devreye girmesini sa\u011flay\u0131n.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\"><a href=\"https:\/\/cnbygele.com\/tr\/product\/bsmjparallel-series-self-healing-low-voltage-parallel-capacitors\/\">BSMJ kendi kendini iyile\u015ftiren \u015fant kondansat\u00f6r<\/a> \u00dcniteler, bir\u00e7ok panonun h\u00e2l\u00e2 kvar \u00e7ekirde\u011fi olarak kulland\u0131\u011f\u0131 metalize film yap\u0131 ta\u015flar\u0131n\u0131 sa\u011flar. Harmoniklerin akort bozulmas\u0131 (detune) gerektirdi\u011fi durumlarda, kondansat\u00f6rleri \u015fu gibi seri reakt\u00f6rlerle e\u015fle\u015ftirin: <a href=\"https:\/\/cnbygele.com\/tr\/product\/cksg-series-low-voltage-series-reactors\/\">CKSG serisi<\/a>.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"AG reaktif g\u00fc\u00e7 kompanzasyon sistemleri i\u00e7in BY81 serisi ak\u0131ll\u0131 kondansat\u00f6rler\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/08\/what-are-capacitor-banks-by81-1.webp\" \/><\/figure>\n<p style=\"margin:0 0 16px;line-height:1.7\">Bu \u00fcr\u00fcn sayfalar\u0131n\u0131n hi\u00e7biri bir ke\u015fif \u00f6l\u00e7\u00fcm\u00fcn\u00fcn veya kvar \u00e7al\u0131\u015fma sayfas\u0131n\u0131n yerini tutmaz. Rakamlar i\u00e7in haz\u0131r oldu\u011funuzda \u015furaya devam edin: <a href=\"https:\/\/cnbygele.com\/tr\/blog\/capacitor-bank-sizing-for-power-factor-correction\/\">g\u00fc\u00e7 fakt\u00f6r\u00fc d\u00fczeltmesi i\u00e7in kondansat\u00f6r bankas\u0131 boyutland\u0131rmas\u0131<\/a>. Boyutland\u0131rma \u00e7al\u0131\u015fmas\u0131 devam ederken kelime da\u011farc\u0131\u011f\u0131n\u0131, yerle\u015fim tercihlerini ve harmonik s\u0131n\u0131rlar\u0131 tutarl\u0131 tutmak i\u00e7in bu tan\u0131m sayfas\u0131n\u0131 kullan\u0131n.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"faq\">SSS<\/h2>\n<h3 style=\"margin:28px 0 12px\">Kondansat\u00f6r ile kondansat\u00f6r grubu aras\u0131ndaki fark nedir?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Tek bir g\u00fc\u00e7 kondansat\u00f6r\u00fc, etiket voltaj\u0131 ve kvar de\u011ferine sahip s\u0131zd\u0131rmaz tek bir \u00fcnitedir. Kondansat\u00f6r bank\u0131 ise grubun uygulaman\u0131n toplam voltaj ve kvar ihtiyac\u0131n\u0131 kar\u015f\u0131layacak \u015fekilde kablolanm\u0131\u015f birden fazla \u00fcnitenin \u2013ayr\u0131ca \u015fasi, muhafaza, sigortalar, \u015falterler ve genellikle bir kontrol cihaz\u0131n\u0131n\u2013 birle\u015fiminden olu\u015fan bir d\u00fczenektir.<\/p>\n<h3 style=\"margin:28px 0 12px\">End\u00fcstriyel tesisler neden kondansat\u00f6r banklar\u0131 kurar?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Tesisler, end\u00fcktif y\u00fckler i\u00e7in yerel reaktif g\u00fc\u00e7 sa\u011flamak, g\u00fc\u00e7 fakt\u00f6r\u00fcn\u00fc y\u00fckseltmek, besleyicilerdeki ve trafolardaki gereksiz ak\u0131m\u0131 azaltmak ve \u2014tarifelerin ge\u00e7erli oldu\u011fu durumlarda\u2014 bir\u00e7ok elektrik da\u011f\u0131t\u0131m \u015firketinin yakla\u015f\u0131k 0,95'in alt\u0131nda uygulayabilece\u011fi d\u00fc\u015f\u00fck g\u00fc\u00e7 fakt\u00f6r\u00fc cezalar\u0131ndan ka\u00e7\u0131nmak i\u00e7in kondansat\u00f6r banklar\u0131 kurar.<\/p>\n<h3 style=\"margin:28px 0 12px\">Kondansat\u00f6r bankalar\u0131 g\u00fc\u00e7 fakt\u00f6r\u00fc d\u00fczeltmesi ile ayn\u0131 \u015fey mi?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Bir kondansat\u00f6r grubu, paralel (\u015fant) g\u00fc\u00e7 fakt\u00f6r\u00fc d\u00fczeltmesi i\u00e7in kullan\u0131lan en yayg\u0131n donan\u0131m par\u00e7alar\u0131ndan biridir, ancak \u201cg\u00fc\u00e7 fakt\u00f6r\u00fc d\u00fczeltmesi\u201d sistemin amac\u0131n\u0131 olu\u015fturur. D\u00fczeltme ayr\u0131ca i\u015fletme uygulamalar\u0131n\u0131, di\u011fer ekipmanlar\u0131 veya elektronik tabanl\u0131 reaktif deste\u011fi de i\u00e7erebilir. Ayr\u0131ca bkz. <a href=\"https:\/\/cnbygele.com\/tr\/blog\/what-is-reactive-power-compensation-key-concepts-explained\/\">Reaktif g\u00fc\u00e7 kompansazyonu<\/a>.<\/p>\n<h3 style=\"margin:28px 0 12px\">Sabit mi otomatik mi \u2014 de\u011fi\u015fken motor y\u00fcklerine hangisi uygundur?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Sabit kondansat\u00f6r grubu, nispeten kararl\u0131 end\u00fcktif talebe uygundur. Otomatik kondansat\u00f6r grubu, \u00fcretim y\u00fck\u00fc de\u011fi\u015ftik\u00e7e kvar kademelerini devreye al\u0131r ve \u00e7\u0131kar\u0131r; b\u00f6ylece tesis, vardiyalar boyunca a\u015f\u0131r\u0131 veya eksik kompanse edilmi\u015f durumda kalmaz.<\/p>\n<h3 style=\"margin:28px 0 12px\">Kondansat\u00f6r grubu harmonik sorunlar\u0131na yol a\u00e7abilir mi?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Evet. Sistem end\u00fcktans\u0131 ile birlikte bir kondansat\u00f6r grubu, bir harmonik frekans yak\u0131n\u0131nda paralel harmonik rezonans olu\u015fturabilir.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">S\u00fcr\u00fcc\u00fc (VFD) a\u011f\u0131rl\u0131kl\u0131 tesislerde bu durum a\u015f\u0131r\u0131 \u0131s\u0131nma, sigorta atmas\u0131, g\u00fcr\u00fclt\u00fc veya artan harmonik bozulma olarak kendini g\u00f6sterir. Detune edilmi\u015f kondansat\u00f6r bankalar\u0131, filtreler veya alternatif reaktif g\u00fc\u00e7 (Q) teknolojileri, \u00f6l\u00e7\u00fcm sonras\u0131nda bu riski ortadan kald\u0131r\u0131r.<\/p>\n<h3 style=\"margin:28px 0 12px\">Bir tesiste banko nereye ba\u011flanmal\u0131d\u0131r?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Ana panoda merkezi, da\u011f\u0131t\u0131m panolar\u0131nda grupland\u0131r\u0131lm\u0131\u015f veya b\u00fcy\u00fck makinelerde yerel, \u00fc\u00e7 klasik d\u00fczendir. Reaktif talebin nerede yo\u011funla\u015ft\u0131\u011f\u0131na ve kademeler devreye girdi\u011finde baraj gerilimi dalgalanmas\u0131n\u0131 ne kadar tolere edebilece\u011finize g\u00f6re se\u00e7im yap\u0131n.<\/p>\n<h3 style=\"margin:28px 0 12px\">kVAR boyutunu nas\u0131l hesaplar\u0131m?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">\u00d6zel \u00e7al\u0131\u015fmam\u0131zda \u00f6l\u00e7\u00fclen ger\u00e7ek g\u00fcc\u00fc ve mevcut ile hedef g\u00fc\u00e7 fakt\u00f6r\u00fc a\u00e7\u0131lar\u0131n\u0131 \u2014veya e\u015fde\u011fer bir \u00e7al\u0131\u015fma sayfas\u0131n\u0131\u2014 kullan\u0131n <a href=\"https:\/\/cnbygele.com\/tr\/blog\/capacitor-bank-sizing-for-power-factor-correction\/\">kondansat\u00f6r bankas\u0131 boyutland\u0131rma<\/a> sayfa. Bu tan\u0131m makalesi, bu matemati\u011fi bilerek yeniden ifade etmemektedir.<\/p>\n<h3 style=\"margin:28px 0 12px\">A\u015fa\u011f\u0131daki durumlarda ak\u0131ll\u0131 kondansat\u00f6r veya harmonik filtreli reakt\u00f6r (detuned reactor) kullanmay\u0131 d\u00fc\u015f\u00fcnebilirsiniz:<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Al\u00e7ak gerilim panosunda entegre alg\u0131lama ve kontroll\u00fc s\u0131f\u0131r ge\u00e7i\u015fli anahtarlama gerekti\u011finde ak\u0131ll\u0131 kondansat\u00f6r mod\u00fcl\u00fcn\u00fc de\u011ferlendirin. Harmonik \u00f6l\u00e7\u00fcmleri d\u00fcz kondansat\u00f6r kademeleri ile rezonans riski g\u00f6sterdi\u011finde seri reakt\u00f6r ekleyin. \u015euradan se\u00e7enekleri inceleyin: <a href=\"https:\/\/cnbygele.com\/tr\/reactive-power-compensator\/\">reaktif g\u00fc\u00e7 kompanzator\u00fc<\/a> malzeme listesi dondurulmadan \u00f6nceki merkez.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"references\">Kaynak\u00e7a<\/h2>\n<ol style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/www.energy.gov\/sites\/prod\/files\/2014\/04\/f15\/mc60405.pdf\" rel=\"nofollow noopener\" target=\"_blank\">ABD Enerji Bakanl\u0131\u011f\u0131 \u2014 G\u00fc\u00e7 Fakt\u00f6r\u00fc Maliyetinin D\u00fc\u015f\u00fcr\u00fclmesi<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/technav.ieee.org\/topic\/capacitor-banks\/\" rel=\"nofollow noopener\" target=\"_blank\">IEEE Teknoloji Navigat\u00f6r\u00fc \u2014 Kondansat\u00f6r Bankalar\u0131<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/www.electricaltechnology.org\/2018\/01\/capacitor-banks-characteristics-and-applications.html\" rel=\"nofollow noopener\" target=\"_blank\">Elektrik Teknolojisi \u2014 Kondansat\u00f6r Bankalar\u0131n\u0131n \u00d6zellikleri ve Uygulamalar\u0131<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/standards.ieee.org\/ieee\/1036\/5912\/\" rel=\"nofollow noopener\" target=\"_blank\">IEEE SA \u2014 IEEE 1036-2020 \u015e\u00f6nt G\u00fc\u00e7 Kondansat\u00f6rlerinin Uygulanmas\u0131 \u0130\u00e7in K\u0131lavuz<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/ipqdf.com\/pq-info\/harmonics\/harmonics-and-power-factor-capacitors-understanding-failure-resonance-and-the-filter-solution\/\" rel=\"nofollow noopener\" target=\"_blank\">IPQDF \u2014 Harmonikler ve G\u00fc\u00e7 Fakt\u00f6r\u00fc Kondansat\u00f6rleri<\/a><\/li>\n<\/ol>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Kondansat\u00f6r bankalar\u0131n\u0131n ne oldu\u011funu, tesis reaktif g\u00fcc\u00fcn\u00fc nas\u0131l sa\u011flad\u0131klar\u0131n\u0131, hangi \u00fcst d\u00fczey tiplerin uygun oldu\u011funu ve harmoniklerin ekipman se\u00e7imini ne zaman de\u011fi\u015ftirdi\u011fini \u00f6\u011frenin.<\/p>","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-2443","post","type-post","status-publish","format-standard","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":7}},"acf":[],"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/posts\/2443","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/comments?post=2443"}],"version-history":[{"count":1,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/posts\/2443\/revisions"}],"predecessor-version":[{"id":2529,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/posts\/2443\/revisions\/2529"}],"wp:attachment":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/media?parent=2443"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/categories?post=2443"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/tags?post=2443"}],"curies":[{"name":"Naber","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}