{"id":2556,"date":"2026-07-15T09:00:00","date_gmt":"2026-07-15T01:00:00","guid":{"rendered":"https:\/\/cnbygele.com\/?p=2556"},"modified":"2026-08-24T18:10:19","modified_gmt":"2026-08-24T10:10:19","slug":"marine-shipbuilding-power-quality-welding-shore-power","status":"publish","type":"post","link":"https:\/\/cnbygele.com\/tr\/blog\/marine-shipbuilding-power-quality-welding-shore-power\/","title":{"rendered":"Denizcilik Gemi \u0130n\u015fa G\u00fc\u00e7 Kalitesi: Kaynak, Sahil G\u00fcc\u00fc, APF ve SVG"},"content":{"rendered":"<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Denizcilik gemi in\u015fas\u0131 g\u00fc\u00e7 kalitesi<\/strong> nadiren tek say\u0131 problemi olur. Modern bir tersane, aral\u0131kl\u0131 kaynak y\u00fckleri, vin\u00e7ler ve pompalar \u00fczerindeki de\u011fi\u015fken frekansl\u0131 s\u00fcr\u00fcc\u00fcler, ge\u00e7ici iskele tedariki ve k\u0131y\u0131 g\u00fc\u00e7 aray\u00fczlerini birle\u015ftirir; bunlar bir \u00e7al\u0131\u015fma modundan di\u011ferine kaynak sertli\u011fini de\u011fi\u015ftirebilir. M\u00fchendisler bu nedenle harmoniklerin, reaktif g\u00fcc\u00fcn ve voltaj dalgalanmas\u0131n\u0131n \u00f6l\u00e7\u00fclen bir g\u00f6r\u00fcn\u00fcm\u00fcne ihtiya\u00e7 duyarlar; APF\/AHF, SVG veya koordine sistem se\u00e7meden \u00f6nce.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Bu k\u0131lavuz, tersanedeki rahats\u0131zl\u0131klar\u0131 nas\u0131l ara\u015ft\u0131raca\u011f\u0131n\u0131z\u0131, harmonik ve reaktif g\u00fc\u00e7 semptomlar\u0131n\u0131 nas\u0131l ay\u0131raca\u011f\u0131n\u0131z\u0131 ve ortak ba\u011flanma noktas\u0131nda (PCC) savunulabilir bir ekipman karar\u0131 destekleyen bir RFQ nas\u0131l haz\u0131rlayaca\u011f\u0131n\u0131z\u0131 a\u00e7\u0131klar.<\/p>\n<nav class=\"b2b-toc\" style=\"background:#f5f8fa;padding:16px 20px;border-radius:8px;margin:0 0 24px\">\n<h2 style=\"margin:42px 0 14px\">\u0130\u00e7indekiler<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"#part-1-why-do-welding-and-converter-loads-make-marine-shipbuilding-power-quality-harder\">B\u00f6l\u00fcm 1. Neden kaynak ve d\u00f6n\u00fc\u015ft\u00fcr\u00fcc\u00fc y\u00fckleri denizcilik gemi in\u015fas\u0131 g\u00fc\u00e7 kalitesini zorla\u015ft\u0131r\u0131r?<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-2-what-should-a-shipyard-measure-before-selecting-mitigation\">B\u00f6l\u00fcm 2. Bir tersane, hafifletme se\u00e7imi \u00f6ncesinde ne \u00f6l\u00e7melidir?<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-3-how-should-the-results-separate-harmonic-reactive-and-voltage-fluctuation-problems\">B\u00f6l\u00fcm 3. Sonu\u00e7lar harmonik, reaktif ve voltaj dalgalanmas\u0131 sorunlar\u0131n\u0131 nas\u0131l ay\u0131rmal\u0131d\u0131r?<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-4-when-does-apf-svg-or-a-combined-approach-fit\">B\u00f6l\u00fcm 4. Ne zaman APF, SVG veya birle\u015fik yakla\u015f\u0131m uygundur?<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-5-why-must-shore-power-and-generator-operation-be-assessed-separately\">B\u00f6l\u00fcm 5. K\u0131y\u0131 g\u00fcc\u00fc ve jenerat\u00f6r i\u015fletimi neden ayr\u0131 ayr\u0131 de\u011ferlendirilmelidir?<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-6-where-should-equipment-and-cts-be-located-in-a-shipyard-distribution-system\">B\u00f6l\u00fcm 6. Ekipmanlar ve CT'ler tersane da\u011f\u0131t\u0131m sisteminde nerede konumland\u0131r\u0131lmal\u0131d\u0131r?<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-7-what-should-a-marine-power-quality-rfq-include-and-when-is-cnbyg-not-a-fit\">B\u00f6l\u00fcm 7. Bir deniz g\u00fc\u00e7 kalitesi RFQ's\u0131 ne i\u00e7ermeli ve CNBYG ne zaman uygun de\u011fildir?<\/a><\/li>\n<\/ul>\n<\/nav>\n<p style=\"margin:0 0 16px;line-height:1.7\">Daha geni\u015f uygulama ba\u011flam\u0131 i\u00e7in, CNBYG'ye bak\u0131n\u0131z <a href=\"https:\/\/cnbygele.com\/tr\/solutions\/marine-shipbuilding\/\">Denizcilik ve Gemi \u0130n\u015fas\u0131 \u00e7\u00f6z\u00fcm\u00fc<\/a>.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/7.CKSG_.webp\" alt=\"Gemi in\u015fas\u0131 g\u00fc\u00e7 kalitesi panelleri i\u00e7in seri reakt\u00f6r ekipman\u0131\" class=\"wp-image-1369\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/7.CKSG_.webp 800w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/7.CKSG_-300x300.webp 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/7.CKSG_-150x150.webp 150w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/7.CKSG_-768x768.webp 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/7.CKSG_-500x500.webp 500w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/7.CKSG_-600x600.webp 600w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/7.CKSG_-100x100.webp 100w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption>Tersane g\u00fc\u00e7 kalitesi panolar\u0131 genellikle bir saha \u00e7al\u0131\u015fmas\u0131ndan sonra reakt\u00f6rler, filtreler ve telafi ekipmanlar\u0131n\u0131 birle\u015ftirir.<\/figcaption><\/figure>\n<h2 style=\"margin:42px 0 14px\" id=\"part-1-why-do-welding-and-converter-loads-make-marine-shipbuilding-power-quality-harder\">B\u00f6l\u00fcm 1. Neden kaynak ve d\u00f6n\u00fc\u015ft\u00fcr\u00fcc\u00fc y\u00fckleri denizcilik gemi in\u015fas\u0131 g\u00fc\u00e7 kalitesini zorla\u015ft\u0131r\u0131r?<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Tersaneler ve tamir at\u00f6lyeleri birka\u00e7 do\u011frusal olmayan ve h\u0131zla de\u011fi\u015fen y\u00fckleri payla\u015f\u0131r:<\/p>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Y\u00fck tipi<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Elektriksel davran\u0131\u015f<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Tipik tersane semptomu<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ark ve diren\u00e7 kaynaklar\u0131<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Aral\u0131kl\u0131 y\u00fcksek ak\u0131m darbeleri<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Gerilim d\u00fc\u015fmeleri, par\u0131lt\u0131, harmonik ak\u0131m<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Gemi in\u015fa tesislerinde ta\u015f\u0131nabilir kaynak<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Tek fazl\u0131 veya dengesiz y\u00fck \u00e7evrimleri<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Faz dengesizli\u011fi ve n\u00f6tr gerilimi<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Vin\u00e7 ve pompa de\u011fi\u015fken frekans s\u00fcr\u00fcc\u00fcleri (VFD)<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Do\u011frultucu \u00f6n u\u00e7lar\u0131 ve h\u0131zl\u0131 tork de\u011fi\u015fimleri<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Harmonikler ve reaktif g\u00fc\u00e7 sal\u0131n\u0131mlar\u0131<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Sahil besleme d\u00f6n\u00fc\u015ft\u00fcr\u00fcc\u00fcleri<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Aray\u00fczde kontroll\u00fc g\u00fc\u00e7 elektroni\u011fi<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Tersane bara sistemiyle bozulma ve kontrol etkile\u015fimi<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ge\u00e7ici jenerat\u00f6r beslemesi<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Sahil beslemesinden farkl\u0131 kaynak empedans\u0131<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ayn\u0131 y\u00fck i\u00e7in de\u011fi\u015fen THD ve gerilim tepkisi<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\">End\u00fcstriyel tesislerdeki kaynak davran\u0131\u015f\u0131, gerilim dalgalanmalar\u0131n\u0131n bir kayna\u011f\u0131 olarak iyi belgelenmi\u015ftir. EPRI k\u0131lavuzu, kaynak makinelerini, g\u00f6rev \u00e7evrimleri h\u0131zl\u0131 bir \u015fekilde yinelendi\u011finde \u00f6l\u00e7\u00fclebilir k\u0131rp\u0131\u015fma (flicker) \u00fcretebilen b\u00fcy\u00fck de\u011fi\u015fken y\u00fckler aras\u0131nda de\u011ferlendirir. Gemi in\u015faat\u0131nda bu etki, kayna\u011f\u0131n birden fazla k\u0131zakta, hareketli vin\u00e7lerin yan\u0131nda ve tersane sahil beslemesi ile ge\u00e7ici jenerat\u00f6r aras\u0131nda ge\u00e7i\u015f yaparken ger\u00e7ekle\u015febilmesi nedeniyle daha da artar.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Kaynak harmoniklerinin otomotiv tesisindeki ilgili bir g\u00f6r\u00fcn\u00fcm\u00fc i\u00e7in bkz. <a href=\"https:\/\/cnbygele.com\/tr\/blog\/welding-robot-harmonic-profile-mitigation\/\">kaynak robotu harmonik profili k\u0131lavuzu<\/a>. Denizcilik projeleri, besleme modu, d\u0131\u015f ortama maruz kalma ve sahil aray\u00fcz\u00fcn\u00fcn kara tabanl\u0131 bir kaynak at\u00f6lyesinin kar\u015f\u0131la\u015fmayabilece\u011fi k\u0131s\u0131tlamalar eklemesi nedeniyle farkl\u0131l\u0131k g\u00f6sterir.<\/p>\n<h2 style=\"margin:42px 0 14px\" id=\"part-2-what-should-a-shipyard-measure-before-selecting-mitigation\">B\u00f6l\u00fcm 2. Bir tersane, hafifletme se\u00e7imi \u00f6ncesinde ne \u00f6l\u00e7melidir?<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Aktif G\u00fc\u00e7 Filtresini (APF) veya Statik Var Jenerat\u00f6r\u00fcn\u00fc (SVG) yaln\u0131zca etiket y\u00fck\u00fc de\u011ferine g\u00f6re boyutland\u0131rmay\u0131n. Ortak Ba\u011flant\u0131 Noktas\u0131n\u0131 (PCC) ve proje i\u00e7in \u00f6nem ta\u015f\u0131yan \u00e7al\u0131\u015fma modlar\u0131n\u0131 tan\u0131mlayarak ba\u015flay\u0131n.<\/p>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">\u00d6l\u00e7\u00fcm<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Tersanelerde neden \u00f6nemlidir<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Gerilim e\u011filimi ve \u00e7\u00f6k\u00fcnt\u00fcleri<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Flicker veya sert kaynak s\u0131n\u0131rlar\u0131n\u0131n a\u015f\u0131l\u0131p a\u015f\u0131lmad\u0131\u011f\u0131n\u0131 g\u00f6sterir<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ak\u0131m harmonikleri ve TDD<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">PCC'de APF\/AHF planlamas\u0131n\u0131 destekler<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Baradaki THDv<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ak\u0131m bozulmas\u0131n\u0131n gerilim kalitesini etkileyip etkilemedi\u011fini g\u00f6sterir<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">G\u00fc\u00e7 fakt\u00f6r\u00fc ve kvar sal\u0131n\u0131m\u0131<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">SVG'nin ilgili olup olmad\u0131\u011f\u0131n\u0131 belirler<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Faz dengesizli\u011fi ve n\u00f6tr ak\u0131m\u0131<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Kar\u0131\u015f\u0131k tek fazl\u0131 kaynak kaynakl\u0131 kaynak ve 3P4W besleyiciler i\u00e7in \u00f6nemlidir<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Pst \/ Plt flicker<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Kaynak d\u00f6ng\u00fclerinden tekrarlayan gerilim hareketlerini yakalar<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Kaynak modu: k\u0131y\u0131 veya jenerat\u00f6r<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Gemi \u00fczerinde yap\u0131lan bir \u00e7al\u0131\u015fma, ayn\u0131 kaynak y\u00fck\u00fc i\u00e7in k\u0131y\u0131 beslemesi ve jenerat\u00f6r beslemesi alt\u0131nda \u00f6nemli \u00f6l\u00e7\u00fcde farkl\u0131 harmonik bozulmalar oldu\u011funu ortaya koymu\u015ftur.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\">Yaln\u0131zca bo\u015fta \u00e7al\u0131\u015fma kontrolleri s\u0131ras\u0131nda de\u011fil, ger\u00e7ek \u00fcretim s\u0131ras\u0131nda da bir g\u00fc\u00e7 kalitesi analiz\u00f6r\u00fc kullan\u0131n. Temsili kaynak faaliyetlerini, vin\u00e7 hareketlerini, pompa \u00e7al\u0131\u015ft\u0131rmalar\u0131n\u0131 ve operat\u00f6rlerin fiilen kulland\u0131\u011f\u0131 t\u00fcm k\u0131y\u0131 elektri\u011fine ge\u00e7i\u015f s\u0131ralar\u0131n\u0131 kaydedin.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">M\u00fchendisler genellikle \u015fu standard\u0131 referans al\u0131r: <a href=\"https:\/\/standards.ieee.org\/ieee\/519\/10677\/\" rel=\"nofollow noopener\" target=\"_blank\">IEEE Std 519-2022<\/a> PCC noktas\u0131nda \u00f6l\u00e7\u00fclen bozulmay\u0131 planlama hedefleriyle kar\u015f\u0131la\u015ft\u0131r\u0131rken. IEEE 519, tan\u0131mlanm\u0131\u015f aray\u00fczdeki kararl\u0131 durum bozulmalar\u0131na uygulan\u0131r; tersane \u00f6zelinde bir kaynak empedans\u0131 \u00e7al\u0131\u015fmas\u0131n\u0131n yerini almaz.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.CKSG_.webp\" alt=\"Denizcilik ve gemi yap\u0131m kompanzasyon sistemleri i\u00e7in reakt\u00f6r bile\u015feni\" class=\"wp-image-1368\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.CKSG_.webp 800w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.CKSG_-300x300.webp 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.CKSG_-150x150.webp 150w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.CKSG_-768x768.webp 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.CKSG_-500x500.webp 500w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.CKSG_-600x600.webp 600w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.CKSG_-100x100.webp 100w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption>Reakt\u00f6r ve kompanzasyon bile\u015fenleri yaln\u0131zca harmonik ve rezonans de\u011ferlendirmesi yap\u0131ld\u0131ktan sonra se\u00e7ilmelidir.<\/figcaption><\/figure>\n<h2 style=\"margin:42px 0 14px\" id=\"part-3-how-should-the-results-separate-harmonic-reactive-and-voltage-fluctuation-problems\">B\u00f6l\u00fcm 3. Sonu\u00e7lar harmonik, reaktif ve voltaj dalgalanmas\u0131 sorunlar\u0131n\u0131 nas\u0131l ay\u0131rmal\u0131d\u0131r?<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Tersanelerde en s\u0131k yap\u0131lan hata, her d\u00fc\u015f\u00fck g\u00fc\u00e7 fakt\u00f6r\u00fc \u00f6l\u00e7\u00fcm\u00fcn\u00fc bir kondansat\u00f6r sorunu olarak veya her gerilim d\u00fc\u015f\u00fcm\u00fcn\u00fc daha fazla kvar ihtiyac\u0131 olarak de\u011ferlendirmektir. \u00dc\u00e7 bozulma grubu birbirinden ba\u011f\u0131ms\u0131z olarak te\u015fhis edilmelidir.<\/p>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Bask\u0131n belirti<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Olas\u0131 temel sorun<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">\u0130lk m\u00fchendislik m\u00fcdahalesi<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Y\u00fcksek ak\u0131m harmonikleri \/ y\u00fcksek TDD<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Do\u011frusal olmayan y\u00fck ak\u0131m\u0131<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u00d6l\u00e7\u00fclen baradaki APF\/AHF \u00e7\u00f6z\u00fcmlerini de\u011ferlendirin<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">H\u0131zl\u0131 reaktif g\u00fc\u00e7 dalgalanmalar\u0131 \/ d\u00fc\u015f\u00fck g\u00fc\u00e7 fakt\u00f6r\u00fc<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Dinamik reaktif g\u00fc\u00e7 talebi<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">SVG veya m\u00fchendislik esaslar\u0131na g\u00f6re tasarlanm\u0131\u015f reaktif g\u00fc\u00e7 deste\u011fini de\u011ferlendirin<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Kabul edilebilir harmonik seviyelerine ra\u011fmen tekrarlayan gerilim d\u00fc\u015f\u00fcmleri<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Flicker \/ kaynak sertli\u011fi<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">G\u00f6rev \u00e7evrimini, fider empedans\u0131n\u0131 ve h\u0131zl\u0131 reaktif g\u00fc\u00e7 deste\u011fini inceleyin<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Kondansat\u00f6rlerin a\u015f\u0131r\u0131 \u0131s\u0131nmas\u0131 veya gereksiz koruma a\u00e7malar\u0131<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Rezonans veya harmonik a\u015f\u0131r\u0131 gerilme<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Spektrum ve detuning g\u00f6zden ge\u00e7irilene kadar kapasitans eklemeyi durdurun<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\">End\u00fcstriyel sistemlerde reaktif g\u00fc\u00e7 temel bilgileri i\u00e7in bak\u0131n\u0131z <a href=\"https:\/\/cnbygele.com\/tr\/blog\/reactive-power-compensation-guide-for-industrial-plants\/\">end\u00fcstriyel tesisler i\u00e7in reaktif g\u00fc\u00e7 kompanzasyon k\u0131lavuzu<\/a>.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>\u00d6nemli:<\/strong> Geleneksel bir kondansat\u00f6r bankas\u0131, kaynak yo\u011fun gemi tersaneleri i\u00e7in varsay\u0131lan bir \u00e7\u00f6z\u00fcm de\u011fildir. Kaynak ve kondansat\u00f6r uygulamalar\u0131yla ilgili forum tart\u0131\u015fmalar\u0131, do\u011frusal olmayan y\u00fckler mevcut oldu\u011funda ripple-ak\u0131m \u0131s\u0131nmas\u0131 ve rezonans konusunda tekrar tekrar endi\u015feleri dile getirir (Kaynak: CR4 forum ke\u015ffi F3; teknik kan\u0131t olarak kullan\u0131lmam\u0131\u015ft\u0131r). Kondansat\u00f6rleri yaln\u0131zca harmonik ve detuning g\u00f6zden ge\u00e7irildikten sonra kullan\u0131n, \u00f6l\u00e7\u00fcm yerine ge\u00e7mek i\u00e7in de\u011fil.<\/p>\n<h2 style=\"margin:42px 0 14px\" id=\"part-4-when-does-apf-svg-or-a-combined-approach-fit\">B\u00f6l\u00fcm 4. Ne zaman APF, SVG veya birle\u015fik yakla\u015f\u0131m uygundur?<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">APF\/AHF ve SVG farkl\u0131 sorunlar\u0131 \u00e7\u00f6zer. Se\u00e7im, \u00f6l\u00e7\u00fclen bask\u0131n bozuklu\u011fa g\u00f6re yap\u0131lmal\u0131d\u0131r.<\/p>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Birincil bulgu<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Tercih edilen hafifletme<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Gerek\u00e7e<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Y\u00fcksek harmonik ak\u0131m \/ y\u00fcksek TDD<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\"><a href=\"https:\/\/cnbygele.com\/tr\/product\/ahf-active-harmonic-filter-harmonic-control\/\">AHF \/ APF Aktif Harmonik Filtre<\/a><\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ger\u00e7ek zamanl\u0131 olarak kompansasyon harmonik ak\u0131m enjekte eder<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">H\u0131zl\u0131 reaktif g\u00fc\u00e7 dalgalanmalar\u0131 \/ d\u00fc\u015f\u00fck g\u00fc\u00e7 fakt\u00f6r\u00fc<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\"><a href=\"https:\/\/cnbygele.com\/tr\/product\/svg-static-var-generators\/\">SVG Statik Var Jenerat\u00f6r\u00fc<\/a><\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Dinamik kvar kompanzasyonu sa\u011flar<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Harmonikler ve reaktif g\u00fc\u00e7 sal\u0131n\u0131mlar\u0131<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">APF + SVG veya entegre g\u00fc\u00e7 kalitesi sistemi<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Harmonik ve var kontrol\u00fcn\u00fc ay\u0131r\u0131r<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Kondansat\u00f6r rezonans riski<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Kapasite eklemeden \u00f6nce m\u00fchendislik \u00e7al\u0131\u015fmas\u0131<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Harmonik voltaj\u0131 art\u0131rmaktan ka\u00e7\u0131n\u0131r<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\">CNBYG, harmonik ak\u0131m hafifletimi i\u00e7in APF'yi ve dinamik reaktif kompanzasyon i\u00e7in SVG'yi konumland\u0131r\u0131r <a href=\"https:\/\/cnbygele.com\/tr\/solutions\/marine-shipbuilding\/\">Denizcilik ve Gemi \u0130n\u015fas\u0131 \u00e7\u00f6z\u00fcm\u00fc<\/a> sayfa. Bu \u00fcr\u00fcn uyumu ifadesi, say\u0131sal THD, PF veya onay sonucu garantisi de\u011fildir. Nihai se\u00e7im, saha \u00f6l\u00e7\u00fcmleri, CT yerle\u015ftirme g\u00f6zden ge\u00e7irmesi ve koruma koordinasyonunu gerektirir.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">APF se\u00e7im temelleri i\u00e7in bkz. <a href=\"https:\/\/cnbygele.com\/tr\/blog\/active-harmonic-filter-ahf-selection-guide\/\">AHF se\u00e7im k\u0131lavuzu<\/a>. Birle\u015fik \u00fcr\u00fcn grubu ba\u011flam\u0131 i\u00e7in bkz. <a href=\"https:\/\/cnbygele.com\/tr\/power-quality-system\/\">G\u00fc\u00e7 Kalitesi Sistemi<\/a> sayfa.<\/p>\n<h2 style=\"margin:42px 0 14px\" id=\"part-5-why-must-shore-power-and-generator-operation-be-assessed-separately\">B\u00f6l\u00fcm 5. K\u0131y\u0131 g\u00fcc\u00fc ve jenerat\u00f6r i\u015fletimi neden ayr\u0131 ayr\u0131 de\u011ferlendirilmelidir?<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">K\u0131y\u0131dan enerji besleme projeleri yaln\u0131zca kablo ve devre kesici \u00e7al\u0131\u015fmalar\u0131ndan ibaret de\u011fildir. <a href=\"https:\/\/standards.ieee.org\/ieee\/80005-1\/5835\/\" rel=\"nofollow noopener\" target=\"_blank\">IEEE\/IEC 80005-1<\/a> aray\u00fcz ekipmanlar\u0131, d\u00f6n\u00fc\u015ft\u00fcr\u00fcc\u00fcler, kontrol, izleme, kilitleme sistemleri ve g\u00fc\u00e7 y\u00f6netimi d\u00e2hil olmak \u00fczere y\u00fcksek gerilimli k\u0131y\u0131 ba\u011flant\u0131 sistemlerini kapsar. Yerel i\u015fletme sahibi gereklilikleri, standard\u0131n \u00f6tesinde ek ko\u015fullar getirebilir.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">G\u00fc\u00e7 kalitesi a\u00e7\u0131s\u0131ndan kritik nokta, kaynak ko\u015fullar\u0131n\u0131n \u00f6l\u00e7\u00fclen tepkiyi de\u011fi\u015ftirebilmesidir. Yay\u0131mlanm\u0131\u015f bir gemi i\u00e7i kaynak \u00e7al\u0131\u015fmas\u0131nda, k\u0131y\u0131dan sa\u011flanan enerji ile s\u0131n\u0131rl\u0131 kapasiteli jenerat\u00f6r beslemesi kar\u015f\u0131la\u015ft\u0131r\u0131lm\u0131\u015f ve ayn\u0131 kaynak makinesi i\u00e7in farkl\u0131 \u00f6l\u00e7\u00fclen harmonik bozulma sonu\u00e7lar\u0131 elde edilmi\u015ftir. Bu durum evrensel bir boyutland\u0131rma kural\u0131 olu\u015fturmaz, ancak a\u015fa\u011f\u0131daki durumlar i\u00e7in ayr\u0131 \u00f6l\u00e7\u00fcm kay\u0131tlar\u0131 tutulmas\u0131n\u0131 hakl\u0131 k\u0131lar:<\/p>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\">Normal k\u0131y\u0131 ba\u011flant\u0131l\u0131 \u00fcretim<\/li>\n<li style=\"margin:0 0 8px\">Jenerat\u00f6r destekli kesinti veya so\u011fuk \u00fct\u00fcleme senaryolar\u0131<\/li>\n<li style=\"margin:0 0 8px\">Kaynaklar aras\u0131ndaki ge\u00e7i\u015f s\u0131ralamalar\u0131<\/li>\n<li style=\"margin:0 0 8px\">Azalt\u0131lm\u0131\u015f y\u00fckle ger\u00e7ekle\u015ftirilen bak\u0131m d\u00f6nemleri<\/li>\n<\/ul>\n<p style=\"margin:0 0 16px;line-height:1.7\">K\u0131y\u0131 g\u00fcc\u00fc, sadece bir kvar problemi de\u011fil, ayn\u0131 zamanda bir aray\u00fcz ve kontrol sistemi de\u011ferlendirmesi olarak ele al\u0131nmal\u0131d\u0131r.<\/p>\n<h2 style=\"margin:42px 0 14px\" id=\"part-6-where-should-equipment-and-cts-be-located-in-a-shipyard-distribution-system\">B\u00f6l\u00fcm 6. Ekipmanlar ve CT'ler tersane da\u011f\u0131t\u0131m sisteminde nerede konumland\u0131r\u0131lmal\u0131d\u0131r?<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">\u00c7o\u011fu tersane projeleri hafifletmeyi \u00fc\u00e7 seviyeden birinde ger\u00e7ekle\u015ftirir:<\/p>\n<ol style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\">Kaynaklama b\u00f6lmesi veya r\u0131ht\u0131m istasyonu hizmet veren besleyici<\/li>\n<li style=\"margin:0 0 8px\">Tersane ana d\u00fc\u015f\u00fck voltaj \u015falt cihaz\u0131<\/li>\n<li style=\"margin:0 0 8px\">Kullan\u0131c\u0131 veya k\u0131y\u0131 beslemesi s\u0131n\u0131rlar\u0131n\u0131n de\u011ferlendirildi\u011fi PCC<\/li>\n<\/ol>\n<p style=\"margin:0 0 16px;line-height:1.7\">Do\u011fru konum, bozuklu\u011fun nerede olu\u015fturuldu\u011funa, hangi ekipman\u0131n hassas oldu\u011funa ve projenin yukar\u0131 ak\u0131\u015f s\u0131n\u0131r\u0131n\u0131 da kar\u015f\u0131lamas\u0131 gerekip gerekmedi\u011fine ba\u011fl\u0131d\u0131r. CT polaritesi, koruma derecelendirmesi, muhafaza eri\u015fimi, havaland\u0131rma ve servis a\u00e7\u0131kl\u0131\u011f\u0131, kVA de\u011feri kadar \u00f6nemlidir.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Devreye alma, ger\u00e7ek kaynak ve vin\u00e7 aktivitesi alt\u0131nda ad\u0131m y\u00fck testlerini i\u00e7ermelidir. Bo\u015fta stabil g\u00f6r\u00fcnen bir cihaz, \u00e7oklu do\u011frusal olmayan y\u00fckler \u00e7ak\u0131\u015ft\u0131\u011f\u0131nda hala d\u00fc\u015f\u00fck performans g\u00f6sterebilir.<\/p>\n<h2 style=\"margin:42px 0 14px\" id=\"part-7-what-should-a-marine-power-quality-rfq-include-and-when-is-cnbyg-not-a-fit\">B\u00f6l\u00fcm 7. Bir deniz g\u00fc\u00e7 kalitesi RFQ's\u0131 ne i\u00e7ermeli ve CNBYG ne zaman uygun de\u011fildir?<\/h2>\n<h3 style=\"margin:28px 0 12px\">Al\u0131c\u0131 sa\u011flamal\u0131d\u0131r<\/h3>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">RFQ giri\u015fi<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Neden \u00f6nemli<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Tipik hata<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Tek hat diyagram\u0131<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">PCC, besleyiciler ve mevcut kompanzasyonlar\u0131 tan\u0131mlar<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Sadece y\u00fck listesi g\u00f6nderimi<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">PCC ve \u00f6l\u00e7\u00fcm noktalar\u0131<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">IEEE 519 tarz\u0131 kar\u015f\u0131la\u015ft\u0131rmalar\u0131 destekler<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Sadece kaynak makinesi \u00fczerinde \u00f6l\u00e7\u00fcm yapar<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Harmonik spektrum ve trend dosyalar\u0131<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">APF s\u0131ras\u0131 ve derecelendirme incelemesini destekler<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Bir dakikal\u0131k anl\u0131k g\u00f6r\u00fcnt\u00fc kullan\u0131m\u0131<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">K\u0131y\u0131 ve jenerat\u00f6r \u00e7al\u0131\u015fma modlar\u0131<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Kaynak stifli\u011fi ve bozulmay\u0131 de\u011fi\u015ftirir<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Bir ayar t\u00fcm modlara uyum sa\u011flar varsay\u0131m\u0131yla<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Transformat\u00f6r \/ jenerat\u00f6r verileri<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Empedans ve fliker ba\u011flam\u0131 i\u00e7in gereklidir<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ge\u00e7ici besleme detaylar\u0131n\u0131n hari\u00e7 tutulmas\u0131<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Mevcut kondansat\u00f6rler, reakt\u00f6rler, filtreler<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Rezonans ve retrofit k\u0131s\u0131tlamalar\u0131n\u0131 ortaya \u00e7\u0131kar\u0131r<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Eski G\u00fc\u00e7 Fakt\u00f6r\u00fc (PF) ekipmanlar\u0131n\u0131n gizlenmesi<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">CT konumlar\u0131 ve kabin k\u0131s\u0131tlamalar\u0131<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Montaj kolayl\u0131\u011f\u0131n\u0131 ve korumay\u0131 belirler<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ak\u0131m trafosu (CT) y\u00f6n\u00fcn\u00fc saha ekibine b\u0131rakmak<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\">CNBYG, \u00f6l\u00e7\u00fclen verileri inceleyebilir ve APF, SVG veya koordine se\u00e7enekleri \u015fu kanal arac\u0131l\u0131\u011f\u0131yla g\u00f6r\u00fc\u015febilir: <a href=\"https:\/\/cnbygele.com\/tr\/contact-us\/\">\u0130leti\u015fim sayfas\u0131<\/a>.<\/p>\n<h3 style=\"margin:28px 0 12px\">Uygunluk S\u0131n\u0131r\u0131<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Bu makale; \u00f6l\u00e7\u00fcm sa\u011flayabilen veya bir \u00e7al\u0131\u015fma ayarlayabilen tersaneleri, onar\u0131m sahalar\u0131n\u0131 ve k\u0131y\u0131dan g\u00fc\u00e7 entegrat\u00f6rlerini destekler. Deniz s\u0131n\u0131fland\u0131rmas\u0131 onay\u0131n\u0131n, k\u0131y\u0131 ba\u011flant\u0131s\u0131 koruma incelemesinin, jenerat\u00f6r boyutland\u0131rmas\u0131n\u0131n veya modele \u00f6zel m\u00fchendislik onay\u0131n\u0131n yerini tutmaz. Bozulma tipi ve \u00e7al\u0131\u015fma modu do\u011frulanmadan yaln\u0131zca kondansat\u00f6r, yaln\u0131zca APF veya yaln\u0131zca SVG ekipman\u0131 \u00f6nermeyin.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/5.CKSG_.webp\" alt=\"Gemi in\u015fas\u0131 harmonik ve kompanzasyon \u00e7al\u0131\u015fmalar\u0131 i\u00e7in \u00fc\u00e7 fazl\u0131 reakt\u00f6r\" class=\"wp-image-1367\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/5.CKSG_.webp 800w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/5.CKSG_-300x300.webp 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/5.CKSG_-150x150.webp 150w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/5.CKSG_-768x768.webp 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/5.CKSG_-500x500.webp 500w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/5.CKSG_-600x600.webp 600w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/5.CKSG_-100x100.webp 100w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption>Reakt\u00f6r ve kompanzasyon bile\u015fenleri, tersane konu\u015fland\u0131rmas\u0131ndan \u00f6nce harmonik ve rezonans incelemesi gerektirir.<\/figcaption><\/figure>\n<h2 style=\"margin:42px 0 14px\">SSS<\/h2>\n<h3 style=\"margin:28px 0 12px\">Denizcilik gemi in\u015fas\u0131 g\u00fc\u00e7 kalitesi nedir?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Tersane kaynak makineleri, s\u00fcr\u00fcc\u00fcler, vin\u00e7ler ve k\u0131y\u0131 veya jenerat\u00f6r beslemesi taraf\u0131ndan olu\u015fturulan voltaj, ak\u0131m, harmonik, fliker ve g\u00fc\u00e7 fakt\u00f6r\u00fc ko\u015fullar\u0131 k\u00fcmesidir.<\/p>\n<h3 style=\"margin:28px 0 12px\">Kaynak makineleri her zaman aktif bir harmonik filtre gerektirir mi?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Hay\u0131r. \u00d6l\u00e7\u00fcmler a\u015f\u0131r\u0131 harmonik ak\u0131m, TDD, gerilim bozulmas\u0131 veya ilgili ekipman sorunlar\u0131 g\u00f6sterdi\u011finde APF gerek\u00e7elidir.<\/p>\n<h3 style=\"margin:28px 0 12px\">Bir SVG her tersane g\u00fc\u00e7 kalitesi sorununu d\u00fczeltebilir mi?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Hay\u0131r. SVG, reaktif g\u00fcc\u00fc ve dinamik kvar deste\u011fini ele al\u0131r. Harmonik ak\u0131m azalt\u0131m\u0131n\u0131n bask\u0131n ihtiya\u00e7 oldu\u011fu durumlarda APF'nin yerini almaz.<\/p>\n<h3 style=\"margin:28px 0 12px\">Kondansat\u00f6r bankalar\u0131 h\u0131zl\u0131 kaynak y\u00fckleri i\u00e7in uygun mudur?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Varsay\u0131lan olarak hay\u0131r. Kaynak ve VFD (de\u011fi\u015fken frekansl\u0131 s\u00fcr\u00fcc\u00fc) y\u00fckleri rezonans veya a\u015f\u0131r\u0131 gerilim riski olu\u015fturabilece\u011finden, kondansat\u00f6rler harmonik ve det\u00fcn (ayars\u0131zl\u0131k) incelemesi gerektirir.<\/p>\n<h3 style=\"margin:28px 0 12px\">K\u0131y\u0131 g\u00fcc\u00fc ve jenerat\u00f6r modlar\u0131 ayn\u0131 ayarlar\u0131 kullanmal\u0131 m\u0131?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Gerekli de\u011fil. Her modu ayr\u0131 ayr\u0131 \u00f6l\u00e7\u00fcn \u00e7\u00fcnk\u00fc kaynak sertli\u011fi ve bozulma de\u011fi\u015febilir.<\/p>\n<h3 style=\"margin:28px 0 12px\">Bir tersanenin PCC'yi nerede tan\u0131mlamas\u0131 gerekir?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Planlama s\u0131n\u0131rlar\u0131n\u0131n, fayda gereksinimlerinin veya sahip hedeflerinin de\u011ferlendirildi\u011fi elektriksel aray\u00fczde\u2014genellikle ana tersane \u015falt cihaz\u0131 veya k\u0131y\u0131 ba\u011flant\u0131 noktas\u0131.<\/p>\n<h3 style=\"margin:28px 0 12px\">APF veya SVG ekipman\u0131n\u0131 boyutland\u0131rmak i\u00e7in hangi veriler gereklidir?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Gerilim, kablolama, y\u00fck envanteri, harmonik g\u00fcnl\u00fckler, PF\/kvar e\u011filimleri, k\u0131v\u0131lc\u0131m verileri, mevcut kompanzasyon detaylar\u0131 ve muhafaza k\u0131s\u0131tlamalar\u0131n\u0131 sa\u011flay\u0131n.<\/p>\n<h3 style=\"margin:28px 0 12px\">Deniz standartlar\u0131 \u00f6nerilen ekipman\u0131 otomatik olarak sertifikaland\u0131r\u0131r m\u0131?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Hay\u0131r. IEEE\/IEC 80005-1 gibi standartlar sistem kapsam\u0131n\u0131 ve aray\u00fcz gereksinimlerini tan\u0131mlar; ekipman hala proje \u00f6zelinde m\u00fchendislik incelemesi gerektirir.<\/p>\n<h2 style=\"margin:42px 0 14px\">Kaynak\u00e7a<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/standards.ieee.org\/ieee\/519\/10677\/\" rel=\"nofollow noopener\" target=\"_blank\">IEEE Std 519-2022<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/standards.ieee.org\/ieee\/80005-1\/5835\/\" rel=\"nofollow noopener\" target=\"_blank\">IEEE\/IEC 80005-1<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/restservice.epri.com\/publicdownload\/000000000001020280\/0\/Product\" rel=\"nofollow noopener\" target=\"_blank\">EPRI k\u0131v\u0131lc\u0131m rehberi end\u00fcstriyel m\u00fc\u015fteriler i\u00e7in<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/doi.org\/10.21279\/1454-864x-18-i2-006\" rel=\"nofollow noopener\" target=\"_blank\">K\u0131y\u0131 ve jenerat\u00f6r beslemesi alt\u0131nda gemi g\u00fcvertesi THD de\u011ferlendirmesi<\/a><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Tersane kayna\u011f\u0131, sahil elektri\u011fi, s\u00fcr\u00fcc\u00fcler ve vin\u00e7lerin denizcilik gemi in\u015fas\u0131 g\u00fc\u00e7 kalitesini nas\u0131l etkiledi\u011fini ve APF veya SVG azalt\u0131m\u0131n\u0131n al\u0131c\u0131lar i\u00e7in ne zaman RFQ'lara uygun oldu\u011funu \u00f6\u011frenin.<\/p>","protected":false},"author":4,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-2556","post","type-post","status-publish","format-standard","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":8}},"acf":[],"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/posts\/2556","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/comments?post=2556"}],"version-history":[{"count":1,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/posts\/2556\/revisions"}],"predecessor-version":[{"id":2615,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/posts\/2556\/revisions\/2615"}],"wp:attachment":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/media?parent=2556"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/categories?post=2556"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/tags?post=2556"}],"curies":[{"name":"Naber","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}