{"id":3979,"date":"2026-11-10T17:00:00","date_gmt":"2026-11-10T09:00:00","guid":{"rendered":"https:\/\/cnbygele.com\/?p=3979"},"modified":"2026-11-12T12:29:12","modified_gmt":"2026-11-12T04:29:12","slug":"capacitor-overpressure-disconnector-clearance","status":"publish","type":"post","link":"https:\/\/cnbygele.com\/tr\/blog\/capacitor-overpressure-disconnector-clearance\/","title":{"rendered":"Kondansat\u00f6r A\u015f\u0131r\u0131 Bas\u0131n\u00e7 Ay\u0131r\u0131c\u0131lar\u0131: Bo\u015fluk ve Ba\u011flant\u0131 Kontrolleri"},"content":{"rendered":"<p>Capacitor overpressure disconnector clearance is the unobstructed movement space required by the installed capacitor&#8217;s pressure-operated safety mechanism. It must come from the exact manufacturer&#8217;s installation drawing or written instructions. Ordinary cooling spacing is not automatically the required expansion distance. Before approving a capacitor layout, check the direction of movement, nearby rigid parts, terminal connections, covers, mounting restraints, and the installation&#8217;s actual tolerances. Do not use a clearance value from a different capacitor family or assume that a neat, compact arrangement leaves the safety mechanism free to operate.<\/p>\n<h2>Why an apparently good installation can obstruct protection<\/h2>\n<p>A capacitor may fit into its mounting space and still have an unsuitable connection arrangement. A rigid connection, close-fitting cover, or structural member can interfere with movement that forms part of a safety mechanism. The engineering question is therefore broader than whether the component can be installed without touching another object. It is whether the documented protective movement remains possible after the entire assembly is complete.<\/p>\n<p>This review complements normal mechanical, electrical, and thermal checks. It does not replace fuse selection, overload assessment, discharge provisions, or an investigation of a failed capacitor. Use the separate <a href=\"https:\/\/cnbygele.com\/blog\/power-capacitor-failure-warning-signs\/\">power capacitor failure guide<\/a> when there is swelling, leakage, heat damage, or evidence of internal failure. Do not press a deformed can back into shape or attempt to reset a pressure-operated device unless the exact manufacturer explicitly provides such a service procedure.<\/p>\n<h2>Establish what the supplied capacitor actually contains<\/h2>\n<p>CNBYG&#8217;s <a href=\"https:\/\/cnbygele.com\/product\/bsmj-cylinder-series-cylindrical-capacitors\/\">BSMJ cylindrical capacitor information<\/a> describes a safety device that disconnects the capacitor following increased internal pressure or failure. Its installation guidance also calls for flexible copper connections. Confirm the delivered model, phase arrangement, mounting method, and installation instructions before translating these general statements into a panel drawing. Do not infer the mechanism&#8217;s dimensions or internal construction from a product photograph.<\/p>\n<p>Ask the supplier for the applicable clearance drawing, the permitted mounting orientation, the movement direction, and any connection restrictions. A document that lists only overall body dimensions may be insufficient. State whether those dimensions describe the normal component envelope or include the protective movement allowance. Keep the supplier&#8217;s clarification with the approved layout so that a later replacement does not silently remove the allowance.<\/p>\n<h2>Keep four different spaces separate<\/h2>\n<p>An electrical clearance concerns insulation between conductive parts. A creepage path follows an insulating surface. A ventilation space supports cooling. A mechanical movement allowance permits a component or mechanism to travel as intended. These requirements can occupy the same physical area, but satisfying one does not prove the others have been satisfied. Treat each as a separate drawing check with its own reference.<\/p>\n<p>The BSMJ product page includes a general installation-spacing instruction, but that statement should not be relabeled as a verified pressure-disconnector travel requirement. If the exact expansion allowance is not supplied, mark that item unresolved and obtain the missing information. It is better to reserve an identifiable space pending confirmation than to approve an invented distance that later becomes difficult to recover inside a finished enclosure.<\/p>\n<p><figure><img decoding=\"async\" alt=\"Cylindrical capacitor expansion clearance and flexible connection planning \u2014 isolated inspection planning\" class=\"wp-image-3977\" height=\"1024\" loading=\"lazy\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/11\/capacitor-overpressure-disconnector-clearance-inspection-20261112.png\" style=\"max-width:100%;height:auto\" width=\"1536\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/11\/capacitor-overpressure-disconnector-clearance-inspection-20261112.png 1536w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/11\/capacitor-overpressure-disconnector-clearance-inspection-20261112-300x200.png 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/11\/capacitor-overpressure-disconnector-clearance-inspection-20261112-1024x683.png 1024w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/11\/capacitor-overpressure-disconnector-clearance-inspection-20261112-768x512.png 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/11\/capacitor-overpressure-disconnector-clearance-inspection-20261112-18x12.png 18w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/11\/capacitor-overpressure-disconnector-clearance-inspection-20261112-600x400.png 600w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" \/><figcaption>Product-reference illustration of BSMJ (Cylinder) Series Cylindrical Capacitors. The equipment is unconnected; no energized test or internal arrangement is shown.<\/figcaption><\/figure>\n<\/p>\n<h2>Build the clearance review around the installed assembly<\/h2>\n<p>The following checklist is qualitative. It intentionally contains no universal distance or cable bend radius. Use values from the installed capacitor, cable, terminal, and enclosure instructions. The evidence should describe the completed arrangement, including covers and adjacent components, rather than an empty enclosure before wiring.<\/p>\n<div style=\"overflow-x:auto;max-width:100%\">\n<table style=\"border-collapse:collapse;width:100%;min-width:640px;table-layout:fixed\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Review item<\/th>\n<th style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Evidence to obtain<\/th>\n<th style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Typical issue to resolve<\/th>\n<th style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Release criterion<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Protective movement<\/td>\n<td style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Model-specific drawing or manufacturer statement<\/td>\n<td style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Movement direction or required envelope is unknown<\/td>\n<td style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Approved allowance is explicitly shown<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Terminal connection<\/td>\n<td style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Approved cable type, routing and termination detail<\/td>\n<td style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">A rigid bridge or taut lead restrains movement<\/td>\n<td style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Connection complies with the component instructions<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Top cover or guard<\/td>\n<td style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Completed assembly dimensions and fixing details<\/td>\n<td style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Cover occupies the required movement space<\/td>\n<td style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Guard remains outside the documented envelope<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Adjacent equipment<\/td>\n<td style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Worst-case location and tolerance stack<\/td>\n<td style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Nearby busbar, bracket or cable trunk restricts movement<\/td>\n<td style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Full assembly retains the required allowance<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Mounting hardware<\/td>\n<td style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Approved clamping and orientation instructions<\/td>\n<td style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Additional restraint changes how the can can move<\/td>\n<td style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Installed fixing method matches the approved design<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Replacement compatibility<\/td>\n<td style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Comparison of original and proposed component<\/td>\n<td style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Similar capacitance but a different mechanical safety arrangement<\/td>\n<td style=\"border:1px solid #d1d5db;padding:10px;text-align:left;vertical-align:top;white-space:normal;overflow-wrap:anywhere\">Revised layout and connection review are accepted<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Review connections as mechanical restraints<\/h2>\n<p>Flexible cable is not automatically a flexible installed connection. A short cable pulled tight between two fixed points can restrain a moving terminal region. The same problem can arise where cable ties, a nearby cable trunk, or an unsupported lug arrangement prevent the necessary movement. Inspect the complete route and its restraints. Do not release a drawing merely because the bill of materials uses the word flexible.<\/p>\n<p>Avoid specifying a field-made loop or a particular slack length without the component and cable instructions. The required arrangement must also maintain electrical clearances, conductor support, termination quality, and the cable&#8217;s permitted bend conditions. A connection solution that protects movement but places stress on an adjacent terminal is incomplete. Ask the panel designer and supplier to resolve the complete arrangement, including strain relief and the permitted location of cable restraints.<\/p>\n<h2>Check covers and adjacent components after wiring<\/h2>\n<p>A layout can change between design approval and final assembly. A substituted cable trunk may be taller, a terminal cover may be deeper, or a support bracket may extend into a previously open space. Verify the actual manufactured arrangement against the approved drawing. Where dimensions are close, include installation tolerances and the equipment&#8217;s permitted orientation instead of relying on an idealized centerline view.<\/p>\n<p>Examine the condition with the specified guard fitted and the enclosure in its normal operating configuration. A photograph taken before the cover is installed does not show the final movement envelope. Record the capacitor location, the obstruction being checked, the reference surfaces, and the method used to establish the distance. Do not remove a necessary protective guard as a permanent workaround; revise the installation to satisfy both guarding and movement requirements.<\/p>\n<h2>Keep inspection separate from destructive verification<\/h2>\n<p>The pressure-operated mechanism should not be tested by deliberately overheating, overvolting, puncturing, or pressurizing an installed capacitor. Such an experiment is not an installation-clearance check. The commissioning task is to verify that the approved component and layout are installed correctly, while any destructive type testing belongs to the manufacturer&#8217;s controlled test program and applicable standards.<\/p>\n<p><a href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.333\" rel=\"noopener nofollow\" target=\"_blank\">OSHA 1910.333<\/a> addresses isolation and stored electrical energy within its scope. Use the site&#8217;s approved electrical safety procedure before touching a capacitor or its connections. An isolated circuit can retain hazardous charge, and an apparently operated disconnector does not prove that every terminal is safe. Verify the actual work boundary rather than treating the visible state of the can as an absence-of-voltage indication.<\/p>\n<h2>What to record when a can is swollen or disconnected<\/h2>\n<p>Remove the affected stage from service under the approved procedure and preserve the condition record. Identify the capacitor, its stage, its connected reactor where applicable, protective devices, recent alarms, and the load condition associated with the event. Photographs should show the can, terminals, mounting restraints, cover, and adjacent parts before the assembly is disturbed. Do not use further switching attempts to determine whether the fault is repeatable.<\/p>\n<p>Separate two conclusions in the report: whether the protective movement was unobstructed, and why the capacitor developed the condition that operated the mechanism. An unobstructed installation does not explain an underlying overload or voltage problem. Conversely, a nearby obstruction does not establish the complete initiating cause. Use the <a href=\"https:\/\/cnbygele.com\/blog\/capacitor-bank-overheating-causes\/\">capacitor-bank overheating investigation<\/a> to organize the broader electrical and thermal evidence.<\/p>\n<p><figure><img decoding=\"async\" alt=\"Cylindrical capacitor expansion clearance and flexible connection planning \u2014 documented equipment review\" class=\"wp-image-3978\" height=\"1024\" loading=\"lazy\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/11\/capacitor-overpressure-disconnector-clearance-records-20261112.png\" style=\"max-width:100%;height:auto\" width=\"1536\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/11\/capacitor-overpressure-disconnector-clearance-records-20261112.png 1536w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/11\/capacitor-overpressure-disconnector-clearance-records-20261112-300x200.png 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/11\/capacitor-overpressure-disconnector-clearance-records-20261112-1024x683.png 1024w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/11\/capacitor-overpressure-disconnector-clearance-records-20261112-768x512.png 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/11\/capacitor-overpressure-disconnector-clearance-records-20261112-18x12.png 18w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/11\/capacitor-overpressure-disconnector-clearance-records-20261112-600x400.png 600w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" \/><figcaption>Product-reference illustration of BSMJ (Cylinder) Series Cylindrical Capacitors. The equipment is unconnected; no energized test or internal arrangement is shown.<\/figcaption><\/figure>\n<\/p>\n<h2>Include the safety arrangement in replacement approval<\/h2>\n<p>Replacement selection must cover more than capacitance and rated voltage. Compare phase configuration, frequency, duty, dimensions, terminals, discharge arrangement, mounting, environmental conditions, and the pressure-protection installation requirements. A shorter or wider replacement can require a different connection route even if it physically fits into the old mounting location. Review the complete stage and obtain approval before treating it as an interchangeable spare.<\/p>\n<p>Supply the vendor with the existing layout and photographs, not only a nameplate request. Ask for the normal envelope and the required safety movement envelope to be identified separately. If a proposed replacement requires more room, resolve that requirement before procurement. Do not accept a drawing note that simply says allow sufficient space without an identifiable source and an inspection criterion. The maintenance team needs a requirement it can verify later.<\/p>\n<h2>Make the final inspection useful for future maintenance<\/h2>\n<p>Create a short record containing the component identification, the approved drawing revision, the source of the movement requirement, the installed connection detail, and the final acceptance decision. Link it to the stage number so that the next capacitor replacement can be checked against the same boundary. Include any restrictions on substituted covers, cable supports, or neighboring equipment that are necessary to preserve the approved allowance.<\/p>\n<p>Add this item to the <a href=\"https:\/\/cnbygele.com\/blog\/capacitor-bank-maintenance-checklist\/\">capacitor-bank maintenance checklist<\/a> after alterations or component replacement. Routine inspection should look for newly added restraints, displaced covers, damaged supports, and signs of overheating. Do not treat the initial factory check as permanent proof after the panel has been modified. Record an unresolved mechanical-safety requirement as an open defect rather than marking the bank ready based solely on an electrical reading.<\/p>\n<h2>Educational background: what a capacitor stores<\/h2>\n<p>Khan Academy&#8217;s <a href=\"https:\/\/www.khanacademy.org\/science\/physics\/circuits-topic\/modal\/v\/capacitors-and-capacitance\" rel=\"noopener nofollow\" target=\"_blank\">capacitors and capacitance lesson<\/a> introduces charge storage and the basic role of the dielectric. It supports understanding why a disconnected capacitor still needs a controlled discharge and verification procedure. The lesson is general physics education; it does not specify pressure-disconnector dimensions, industrial mounting details, or safe handling limits for the installed product.<\/p>\n<div style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"><iframe allowfullscreen=\"\" loading=\"lazy\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/u-jigaMJT10\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" title=\"Capacitors and capacitance | Circuits | Physics | Khan Academy\"><\/iframe><\/div>\n<p><a href=\"https:\/\/www.youtube.com\/watch?v=u-jigaMJT10\" rel=\"noopener nofollow\" target=\"_blank\">Watch the educational lesson<\/a><\/p>\n<h2>Frequently asked questions<\/h2>\n<h3>Is ventilation spacing the same as disconnector clearance?<\/h3>\n<p>No. Cooling space and mechanical movement allowance serve different purposes. Verify both against the installed product instructions and the completed panel layout. Do not use a general spacing value as an undocumented expansion requirement.<\/p>\n<h3>Does flexible cable guarantee free protective movement?<\/h3>\n<p>No. A flexible cable can still restrain movement if it is too taut or fixed in an unsuitable position. Review the installed route, restraints, termination detail, and required movement together under the manufacturer&#8217;s instructions.<\/p>\n<h3>Can a swollen capacitor be pressed back into shape?<\/h3>\n<p>Do not reshape or attempt to reset a failed capacitor as a field repair. Keep it in the designated safe state and follow the manufacturer&#8217;s assessment, replacement, handling, and disposal instructions after appropriate electrical isolation and verification.<\/p>\n<h3>Can a replacement use the original clearance drawing?<\/h3>\n<p>Only after confirming that the drawing applies to the replacement&#8217;s complete mechanical and safety arrangement. Similar electrical ratings do not establish identical terminals, dimensions, mounting conditions, or pressure-protection movement requirements.<\/p>\n<p><script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Is ventilation spacing the same as disconnector clearance?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. Cooling space and mechanical movement allowance serve different purposes. Verify both against the installed product instructions and the completed panel layout. Do not use a general spacing value as an undocumented expansion requirement.\"}}, {\"@type\": \"Question\", \"name\": \"Does flexible cable guarantee free protective movement?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. A flexible cable can still restrain movement if it is too taut or fixed in an unsuitable position. Review the installed route, restraints, termination detail, and required movement together under the manufacturer's instructions.\"}}, {\"@type\": \"Question\", \"name\": \"Can a swollen capacitor be pressed back into shape?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Do not reshape or attempt to reset a failed capacitor as a field repair. Keep it in the designated safe state and follow the manufacturer's assessment, replacement, handling, and disposal instructions after appropriate electrical isolation and verification.\"}}, {\"@type\": \"Question\", \"name\": \"Can a replacement use the original clearance drawing?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Only after confirming that the drawing applies to the replacement's complete mechanical and safety arrangement. Similar electrical ratings do not establish identical terminals, dimensions, mounting conditions, or pressure-protection movement requirements.\"}}]}<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Evrensel bir a\u00e7\u0131kl\u0131k mesafesi varsaymadan kondansat\u00f6r bas\u0131n\u00e7 ay\u0131r\u0131c\u0131s\u0131n\u0131n hareketini, ba\u011flant\u0131 esnekli\u011fini, kapaklar\u0131n\u0131 ve de\u011fi\u015ftirme onay\u0131n\u0131 kontrol edin.<\/p>","protected":false},"author":4,"featured_media":3976,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[218],"class_list":["post-3979","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-capacitor-bank"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":8}},"acf":[],"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/posts\/3979","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/comments?post=3979"}],"version-history":[{"count":1,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/posts\/3979\/revisions"}],"predecessor-version":[{"id":3980,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/posts\/3979\/revisions\/3980"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/media\/3976"}],"wp:attachment":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/media?parent=3979"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/categories?post=3979"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/tags?post=3979"}],"curies":[{"name":"Naber","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}