{"id":1291,"date":"2026-04-29T10:02:18","date_gmt":"2026-04-29T02:02:18","guid":{"rendered":"https:\/\/w6pown520g.wpdns.site\/?post_type=product&#038;p=1291"},"modified":"2026-07-17T16:09:58","modified_gmt":"2026-07-17T08:09:58","slug":"svg-static-var-generators","status":"publish","type":"product","link":"https:\/\/cnbygele.com\/tr\/product\/svg-static-var-generators\/","title":{"rendered":"Statik Var Jenerat\u00f6r\u00fc (SVG) &amp; Geli\u015fmi\u015f Statik Var Jenerat\u00f6r\u00fc (ASVG)"},"content":{"rendered":"<h2>\u00dcr\u00fcn A\u00e7\u0131klamas\u0131<\/h2>\n<p>Reaktif g\u00fc\u00e7 t\u00fcketimi, operat\u00f6rler taraf\u0131ndan ek \u00fccretlendirmeleri i\u00e7erir, bu nedenle bir SVG kompansat\u00f6r kullan\u0131m\u0131 elektrik faturalar\u0131n\u0131 etkin \u015fekilde azalt\u0131r ve reaktif g\u00fc\u00e7 t\u00fcketimiyle ilgili maliyetleri tamamen ortadan kald\u0131r\u0131r.<\/p>\n<ul>\n<li>An\u0131nda ve hassas reaktif g\u00fc\u00e7 kompensasyonu<\/li>\n<li>Aktif harmonik bast\u0131rma<\/li>\n<li>De\u011fi\u015fen \u00e7al\u0131\u015fma ko\u015fullar\u0131na dinamik uyum<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1609\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control.webp\" alt=\"\" width=\"1500\" height=\"872\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control.webp 1500w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-300x174.webp 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-1024x595.webp 1024w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-768x446.webp 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-600x349.webp 600w\" sizes=\"auto, (max-width: 1500px) 100vw, 1500px\" \/><\/p>\n<p><strong><b>SVG \u00e7al\u0131\u015fma prensibi<\/b><\/strong><\/p>\n<p>SVG kompansat\u00f6r\u00fcn\u00fcn \u00e7al\u0131\u015fma prensibi, \u015febekedeki ak\u0131m ve gerilim dalga bi\u00e7imlerinin s\u00fcrekli izlenmesine dayan\u0131r.<\/p>\n<p>Sistem, y\u00fck\u00fcn do\u011fas\u0131ndan kaynaklanan faz sapmalar\u0131n\u0131 tespit etti\u011finde, hemen kar\u015f\u0131 \u00f6zelliklere sahip bir kompansasyon ak\u0131m\u0131 \u00fcretir. Almanya men\u015feli Infineon\u2019dan IGBT mod\u00fcller ve hassas PWM kontrol kullan\u0131m\u0131 sayesinde, cihaz g\u00fc\u00e7 fakt\u00f6r\u00fcn\u00fc ger\u00e7ek zamanl\u0131 olarak d\u00fczeltir, end\u00fcktif ve kapasitif reaktif g\u00fcc\u00fc kompense eder. Bu aktif \u00e7al\u0131\u015fma modu, y\u00fck dalgalanmalar\u0131na ra\u011fmen ideal g\u00fc\u00e7 kayna\u011f\u0131 parametrelerinin korunmas\u0131n\u0131 sa\u011flar, ola\u011fan\u00fcst\u00fc g\u00fcvenilirlik ve en y\u00fcksek kompansasyon hassasiyetini garanti eder.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1613\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1.webp\" alt=\"\" width=\"2480\" height=\"2339\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1.webp 2480w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-300x283.webp 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-1024x966.webp 1024w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-768x724.webp 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-1536x1449.webp 1536w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-2048x1932.webp 2048w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-600x566.webp 600w\" sizes=\"auto, (max-width: 2480px) 100vw, 2480px\" \/><\/p>\n<h2><strong><b>Duvara Monte SVG<\/b><\/strong><\/h2>\n<p><strong>Teknik \u015eartname<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"174\">T\u0130P<\/td>\n<td width=\"149\">Seri 230V<\/td>\n<td width=\"155\">Seri 400V<\/td>\n<td width=\"91\">Seri 500V<\/td>\n<td width=\"91\">Seri 690V<\/td>\n<\/tr>\n<tr>\n<td>Kapasite<\/td>\n<td width=\"149\">20kVar\/30kVar\/35kVar\/<br \/>\n50kVar\/70kVar\/100kVar<\/td>\n<td width=\"155\">10kVar\/15kVar\/20kVar\/<br \/>\n30kVar\/35kVar\/50kVar\/<br \/>\n75kVar\/100kVar\/150kVar<\/td>\n<td>85kVar<\/td>\n<td>120kVar<\/td>\n<\/tr>\n<tr>\n<td>Voltaj<\/td>\n<td>230 V (+\/-20%)<\/td>\n<td>400 V (+\/-20%)<\/td>\n<td>500 V (+\/-20%)<\/td>\n<td>690 V (+\/-201 TP3T)<\/td>\n<\/tr>\n<tr>\n<td>Frekans<\/td>\n<td colspan=\"4\">50 Hz (+\/-5%)<\/td>\n<\/tr>\n<tr>\n<td>Evre<\/td>\n<td>1 Faz<\/td>\n<td colspan=\"3\">3 A\u015fama<\/td>\n<\/tr>\n<tr>\n<td>Yan\u0131t s\u00fcresi<\/td>\n<td colspan=\"4\">&lt;10ms<\/td>\n<\/tr>\n<tr>\n<td>kompansasyon katsay\u0131s\u0131<\/td>\n<td colspan=\"4\">&gt;95%<\/td>\n<\/tr>\n<tr>\n<td>Cihaz verimlili\u011fi<\/td>\n<td colspan=\"4\">&gt;97%<\/td>\n<\/tr>\n<tr>\n<td>Anahtarlama frekans\u0131<\/td>\n<td>32kHz<\/td>\n<td>16kHz<\/td>\n<td>12,8kHz<\/td>\n<td>12,8kHz<\/td>\n<\/tr>\n<tr>\n<td>\u0130\u015flev<\/td>\n<td colspan=\"4\">Reaktif g\u00fc\u00e7 kompanzasyonu<\/td>\n<\/tr>\n<tr>\n<td>Mod\u00fcl say\u0131s\u0131<\/td>\n<td colspan=\"4\" width=\"488\">S\u0131n\u0131rs\u0131z. Bir izleme mod\u00fcl\u00fc \u015fu \u015fekilde donat\u0131labilir<br \/>\n32 akt\u00fcat\u00f6r\/uygulama mod\u00fcl\u00fc ile<\/td>\n<\/tr>\n<tr>\n<td>\u0130leti\u015fim<\/td>\n<td colspan=\"4\">\u00c7ift kanall\u0131 RS485 (Kablosuz WiFi\/GPRS ileti\u015fimi deste\u011fi)<\/td>\n<\/tr>\n<tr>\n<td>Deniz seviyesinden y\u00fckseklik<\/td>\n<td colspan=\"4\">&lt;2000m<\/td>\n<\/tr>\n<tr>\n<td>S\u0131cakl\u0131k<\/td>\n<td colspan=\"4\">-20~+50\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Nem<\/td>\n<td colspan=\"4\">&lt;90%<\/td>\n<\/tr>\n<tr>\n<td>Kirlilik Derecesi<\/td>\n<td colspan=\"4\">Seviye 2'nin alt\u0131nda<\/td>\n<\/tr>\n<tr>\n<td>Koruyucular<\/td>\n<td colspan=\"4\" width=\"488\">A\u015f\u0131r\u0131 y\u00fck, A\u015f\u0131r\u0131 ak\u0131m, A\u015f\u0131r\u0131 gerilim, Besleme \u015febekesi asimetrisli\u011fine kar\u015f\u0131,<br \/>\nTermal\/A\u015f\u0131r\u0131 s\u0131cakl\u0131k, Frekans dalgalanmalar\u0131 K\u0131sa devre<\/td>\n<\/tr>\n<tr>\n<td>G\u00fcr\u00fclt\u00fc<\/td>\n<td>&lt;50dB<\/td>\n<td>&lt;60dB<\/td>\n<td colspan=\"2\">&lt;65dB<\/td>\n<\/tr>\n<tr>\n<td>Kurulum y\u00f6ntemi<\/td>\n<td colspan=\"4\">Duvara Montaj<\/td>\n<\/tr>\n<tr>\n<td>Ba\u011flant\u0131<\/td>\n<td colspan=\"4\">\u00dcstten (Duvara montajl\u0131)<\/td>\n<\/tr>\n<tr>\n<td>Koruma derecesi<\/td>\n<td colspan=\"4\">IP20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong><b>\u00dcr\u00fcn Boyut Bilgileri<\/b><\/strong><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-962\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/4.SVG.webp\" alt=\"\" width=\"1500\" height=\"816\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"101\">Model<\/td>\n<td width=\"246\">Kapasite (kvar)<\/td>\n<td width=\"71\">Gerilim(V)<\/td>\n<td width=\"113\">Boyutlar(G*Y*D)(mm)<\/td>\n<td width=\"133\">So\u011futma<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.23-2L-W<\/td>\n<td>20Kvar\/30Kvar\/35Kvar<\/td>\n<td>230V<\/td>\n<td>380x424x88<\/td>\n<td>Zorlamal\u0131 Hava So\u011futma<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.23-2L-W<\/td>\n<td>50Kvar\/70Kvar\/100Kvar<\/td>\n<td>230V<\/td>\n<td>500x550x130<\/td>\n<td>Zorlamal\u0131 Hava So\u011futma<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.4-4L-W<\/td>\n<td>10Kvar\/15Kvar\/20Kvar\/30Kvar\/35Kvar<\/td>\n<td>400V<\/td>\n<td>380x424x88<\/td>\n<td>Zorlamal\u0131 Hava So\u011futma<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.4-4L-W<\/td>\n<td>50Kvar\/75Kvar\/100Kvar\/150Kvar<\/td>\n<td>400V<\/td>\n<td>500x550x130<\/td>\n<td>Zorlamal\u0131 Hava So\u011futma<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.5-4L-W<\/td>\n<td>85Kvar<\/td>\n<td>500V<\/td>\n<td>500x550x130<\/td>\n<td>Zorlamal\u0131 Hava So\u011futma<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.69-4L-W<\/td>\n<td>120Kvar<\/td>\n<td>690V<\/td>\n<td>500x550x130<\/td>\n<td>Zorlamal\u0131 Hava So\u011futma<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u015eartname standart tiplerle s\u0131n\u0131rl\u0131d\u0131r; di\u011fer boyutlar talep \u00fczerine temin edilebilir.<\/p>\n<h2><strong><b>Raf montajl\u0131 SVG<\/b><\/strong><\/h2>\n<p><strong>Teknik \u015eartname<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"183\">T\u0130P<\/td>\n<td width=\"146\">Seri 230V<\/td>\n<td width=\"153\">Seri 400V<\/td>\n<td width=\"93\">Seri 500V<\/td>\n<td width=\"93\">Seri 690V<\/td>\n<\/tr>\n<tr>\n<td>Kapasite<\/td>\n<td width=\"146\">20kVar\/30kVar\/35kVar\/<br \/>\n50kVar\/70kVar\/100kVar<\/td>\n<td width=\"153\">10kVar\/15kVar\/20kVar\/<br \/>\n30kVar\/35kVar\/50kVar\/<br \/>\n75kVar\/100kVar\/150kVar<\/td>\n<td>85kVar<\/td>\n<td>120kVar<\/td>\n<\/tr>\n<tr>\n<td>Voltaj<\/td>\n<td>230 V (+\/-20%)<\/td>\n<td>400 V (+\/-20%)<\/td>\n<td>500 V (+\/-20%)<\/td>\n<td>690 V (+\/-201 TP3T)<\/td>\n<\/tr>\n<tr>\n<td>Frekans<\/td>\n<td colspan=\"4\">50 Hz (+\/-5%)<\/td>\n<\/tr>\n<tr>\n<td>Evre<\/td>\n<td>1 Faz<\/td>\n<td colspan=\"3\">3 A\u015fama<\/td>\n<\/tr>\n<tr>\n<td>Yan\u0131t s\u00fcresi<\/td>\n<td colspan=\"4\">&lt;10ms<\/td>\n<\/tr>\n<tr>\n<td>kompansasyon katsay\u0131s\u0131<\/td>\n<td colspan=\"4\">&gt;95%<\/td>\n<\/tr>\n<tr>\n<td>Cihaz verimlili\u011fi<\/td>\n<td colspan=\"4\">&gt;97%<\/td>\n<\/tr>\n<tr>\n<td>Anahtarlama frekans\u0131<\/td>\n<td>32kHz<\/td>\n<td>16kHz<\/td>\n<td>12,8kHz<\/td>\n<td>12,8kHz<\/td>\n<\/tr>\n<tr>\n<td>\u0130\u015flev<\/td>\n<td colspan=\"4\">Reaktif g\u00fc\u00e7 kompanzasyonu<\/td>\n<\/tr>\n<tr>\n<td>Mod\u00fcl say\u0131s\u0131<\/td>\n<td colspan=\"4\" width=\"487\">S\u0131n\u0131rs\u0131z. Bir izleme mod\u00fcl\u00fc \u015fu \u015fekilde donat\u0131labilir<br \/>\n32 akt\u00fcat\u00f6r\/uygulama mod\u00fcl\u00fc ile<\/td>\n<\/tr>\n<tr>\n<td>\u0130leti\u015fim<\/td>\n<td colspan=\"4\">\u00c7ift kanall\u0131 RS485 (Kablosuz WiFi\/GPRS ileti\u015fimi deste\u011fi)<\/td>\n<\/tr>\n<tr>\n<td>Deniz seviyesinden y\u00fckseklik<\/td>\n<td colspan=\"4\">&lt;2000m<\/td>\n<\/tr>\n<tr>\n<td>S\u0131cakl\u0131k<\/td>\n<td colspan=\"4\">-20~+50\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Nem<\/td>\n<td colspan=\"4\">&lt;90%<\/td>\n<\/tr>\n<tr>\n<td>Kirlilik Derecesi<\/td>\n<td colspan=\"4\">Seviye 2'nin alt\u0131nda<\/td>\n<\/tr>\n<tr>\n<td>Koruyucular<\/td>\n<td colspan=\"4\" width=\"487\">A\u015f\u0131r\u0131 y\u00fck, A\u015f\u0131r\u0131 ak\u0131m, A\u015f\u0131r\u0131 gerilim, Besleme \u015febekesi asimetrisli\u011fine kar\u015f\u0131,<br \/>\nTermal\/A\u015f\u0131r\u0131 s\u0131cakl\u0131k, Frekans dalgalanmalar\u0131 K\u0131sa devre<\/td>\n<\/tr>\n<tr>\n<td>G\u00fcr\u00fclt\u00fc<\/td>\n<td>&lt;50dB<\/td>\n<td>&lt;60dB<\/td>\n<td colspan=\"2\">&lt;65dB<\/td>\n<\/tr>\n<tr>\n<td>Kurulum y\u00f6ntemi<\/td>\n<td colspan=\"4\">Raf montaj\u0131<\/td>\n<\/tr>\n<tr>\n<td>Ba\u011flant\u0131<\/td>\n<td colspan=\"4\">Arkadan (Raf)<\/td>\n<\/tr>\n<tr>\n<td>Koruma derecesi<\/td>\n<td colspan=\"4\">IP20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><b>\u00dcr\u00fcn Boyut Bilgileri<\/b><\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1615\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators.webp\" alt=\"\" width=\"1500\" height=\"765\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators.webp 1500w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators-300x153.webp 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators-1024x522.webp 1024w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators-768x392.webp 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators-600x306.webp 600w\" sizes=\"auto, (max-width: 1500px) 100vw, 1500px\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"101\">Model<\/td>\n<td width=\"246\">Kapasite (kvar)<\/td>\n<td width=\"71\">Gerilim(V)<\/td>\n<td width=\"113\">Boyutlar(G*Y*D)(mm)<\/td>\n<td width=\"133\">So\u011futma<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.23-2L-R<\/td>\n<td>20Kvar\/30Kvar\/35Kvar<\/td>\n<td>230V<\/td>\n<td>380x424x88<\/td>\n<td>Zorlamal\u0131 Hava So\u011futma<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.23-2L-R<\/td>\n<td>50Kvar\/70Kvar\/100Kvar<\/td>\n<td>230V<\/td>\n<td>500x550x130<\/td>\n<td>Zorlamal\u0131 Hava So\u011futma<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.4-4L-R<\/td>\n<td>10Kvar\/15Kvar\/20Kvar\/30Kvar\/35Kvar<\/td>\n<td>400V<\/td>\n<td>380x424x88<\/td>\n<td>Zorlamal\u0131 Hava So\u011futma<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.4-4L-R<\/td>\n<td>50Kvar\/75Kvar\/100Kvar\/150Kvar<\/td>\n<td>400V<\/td>\n<td>500x550x130<\/td>\n<td>Zorlamal\u0131 Hava So\u011futma<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.5-4L-R<\/td>\n<td>85Kvar<\/td>\n<td>500V<\/td>\n<td>500x550x130<\/td>\n<td>Zorlamal\u0131 Hava So\u011futma<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.69-4L-R<\/td>\n<td>120Kvar<\/td>\n<td>690V<\/td>\n<td>500x550x130<\/td>\n<td>Zorlamal\u0131 Hava So\u011futma<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u015eartname standart tiplerle s\u0131n\u0131rl\u0131d\u0131r; di\u011fer boyutlar talep \u00fczerine temin edilebilir.<\/p>\n<p><!-- CNBYG-HUB-RESOURCES-START --><\/p>\n<section>\n<h2>SVG \/ ASVG \u00fcr\u00fcn-kaynak merkezi<\/h2>\n<p>Statik Reaktif G\u00fc\u00e7 Jenerat\u00f6r\u00fc (SVG) ve Geli\u015fmi\u015f Statik Reaktif G\u00fc\u00e7 Jenerat\u00f6r\u00fc (ASVG), dinamik reaktif g\u00fc\u00e7 telafi projeleri i\u00e7in \u00fcr\u00fcn serisi terimleridir. CNBYG, proje verileriyle gereken yan\u0131t\u0131, reaktif g\u00fc\u00e7 aral\u0131\u011f\u0131n\u0131, ba\u011flant\u0131 ko\u015fullar\u0131n\u0131, y\u00fck de\u011fi\u015fimini, mevcut ekipman\u0131 ve kurulum k\u0131s\u0131tlamalar\u0131n\u0131 de\u011ferlendirir. Bir \u00fcr\u00fcn sayfas\u0131, g\u00fc\u00e7 fakt\u00f6r\u00fc, voltaj veya uyum performans\u0131n\u0131n garantisi de\u011fildir.<\/p>\n<p><a href=\"\/tr\/contact-us\/\">Bir SVG\/ASVG uygulamas\u0131n\u0131 tart\u0131\u015f\u0131n<\/a><\/p>\n<\/section>\n<section>\n<h2>Uygulama giri\u015f noktalar\u0131<\/h2>\n<div>\n<article>\n<h3><a href=\"https:\/\/cnbygele.com\/tr\/blog\/svg-vs-asvg-how-to-choose-for-industrial-plants\/\">H\u0131zla de\u011fi\u015fen end\u00fcstriyel y\u00fckler<\/a><\/h3>\n<p>Teknik sorular\u0131 haz\u0131rlamak i\u00e7in kar\u015f\u0131la\u015ft\u0131rma makalesini kullan\u0131n, ard\u0131ndan uygulama verilerini do\u011frulay\u0131n.<\/p>\n<\/article>\n<article>\n<h3><a href=\"https:\/\/cnbygele.com\/tr\/blog\/ev-charging-station-voltage-fluctuation-svg-guide\/\">EV \u015farj\u0131 ve voltaj dalgalanmas\u0131<\/a><\/h3>\n<p>\u015earj profilleri ve \u015febeke taraf\u0131ndaki ko\u015fullar, proje ba\u011flant\u0131 noktas\u0131nda incelenmelidir.<\/p>\n<\/article>\n<article>\n<h3><a href=\"https:\/\/cnbygele.com\/tr\/blog\/photovoltaic-inverter-harmonics-svg-apf-mitigation\/\">Fotovoltaik invert\u00f6r uygulamalar\u0131<\/a><\/h3>\n<p>Ekipman \u00f6zellikleri belirlenmeden \u00f6nce reaktif g\u00fc\u00e7 ve harmonik hedeflerini ayr\u0131 ayr\u0131 ele al\u0131n.<\/p>\n<\/article>\n<article>\n<h3><a href=\"https:\/\/cnbygele.com\/tr\/blog\/marine-shipbuilding-power-quality-welding-shore-power\/\">Denizcilik ve gemi in\u015faat\u0131<\/a><\/h3>\n<p>\u0130lgili gemi veya tersane projesi i\u00e7in k\u0131y\u0131dan g\u00fc\u00e7 sa\u011flama (shore-power), kaynak ve kurulum k\u0131s\u0131tlamalar\u0131n\u0131 g\u00f6zden ge\u00e7irin.<\/p>\n<\/article>\n<\/div>\n<\/section>\n<section>\n<h2>SVG \/ ASVG se\u00e7im girdileri<\/h2>\n<ul>\n<li>Tek hat \u015femas\u0131, anma gerilimi, frekans, trafo kapasitesi ve kurulum yeri<\/li>\n<li>Reaktif g\u00fc\u00e7 profili, g\u00fc\u00e7 fakt\u00f6r\u00fc hedefi, y\u00fck de\u011fi\u015fimi ve ilgili voltaj verileri<\/li>\n<li>Mevcut kondansat\u00f6r bankalar\u0131, reakt\u00f6rler, filtreleme ekipmanlar\u0131, koruma ve kontrol aray\u00fczleri<\/li>\n<li>\u00c7evresel, pano muhafazas\u0131, termal, kablo ve devreye alma k\u0131s\u0131tlamalar\u0131<\/li>\n<\/ul>\n<p>Ayr\u0131 bir harmonik ak\u0131m sorunu olan sistemler i\u00e7in \u015funlar\u0131 inceleyin: <a href=\"https:\/\/cnbygele.com\/tr\/product\/ahf-active-harmonic-filter-harmonic-control\/\">AHF\/APF \u00fcr\u00fcn merkezi<\/a> ve hedeflerin koordine ekipman gerektirip gerektirmedi\u011fini belirleyin.<\/p>\n<\/section>\n<section>\n<h2>Se\u00e7ilen teknik kaynaklar<\/h2>\n<p>Proje \u00f6nerisinde bulunmadan \u00f6nce teknik soruyu \u00e7er\u00e7evelemek i\u00e7in bu makaleleri kullan\u0131n.<\/p>\n<ul>\n<li><a href=\"https:\/\/cnbygele.com\/tr\/blog\/svg-vs-asvg-how-to-choose-for-industrial-plants\/\">SVG ve ASVG: End\u00fcstriyel tesisler i\u00e7in se\u00e7im yapma<\/a><\/li>\n<li><a href=\"https:\/\/cnbygele.com\/tr\/blog\/advanced-static-var-generator-asvg-explained\/\">Geli\u015fmi\u015f Statik Var Jenerat\u00f6r\u00fc (ASVG) a\u00e7\u0131kland\u0131<\/a><\/li>\n<li><a href=\"https:\/\/cnbygele.com\/tr\/blog\/ev-charging-station-voltage-fluctuation-svg-guide\/\">EV \u015farj istasyonu voltaj dalgalanmas\u0131 ve SVG<\/a><\/li>\n<li><a href=\"https:\/\/cnbygele.com\/tr\/blog\/photovoltaic-inverter-harmonics-svg-apf-mitigation\/\">PV invert\u00f6r harmonikleri: SVG ve APF mitigasyonu<\/a><\/li>\n<li><a href=\"https:\/\/cnbygele.com\/tr\/blog\/static-var-compensation-system-design-basics\/\">Statik var kompanzasyon sistemi tasar\u0131m esaslar\u0131<\/a><\/li>\n<li><a href=\"https:\/\/cnbygele.com\/tr\/blog\/marine-shipbuilding-power-quality-welding-shore-power\/\">Denizcilik ve gemi in\u015faat\u0131 g\u00fc\u00e7 kalitesi, kaynak ve k\u0131y\u0131 g\u00fcc\u00fc<\/a><\/li>\n<\/ul>\n<\/section>\n<section>\n<h2>\u00dcretici ve teklif talebi (RFQ) bilgileri<\/h2>\n<p>Bir \u00fcretici g\u00f6r\u00fc\u015fmesi i\u00e7in, yaln\u0131zca anahtar kelimeden bir de\u011ferlendirme istemek yerine proje elektrik verilerini ve montaj k\u0131s\u0131tlamalar\u0131n\u0131 sa\u011flay\u0131n. CNBYG, \u00fcr\u00fcn hatt\u0131 kullan\u0131labilirli\u011fi, teknik dok\u00fcmantasyon ve proje girdileri hakk\u0131nda tart\u0131\u015fabilir. <a href=\"\/tr\/contact-us\/\">\u0130leti\u015fim sayfas\u0131<\/a>.<\/p>\n<\/section>\n<section>\n<h2>S\u0131k sorulan sorular<\/h2>\n<h3>SVG t\u00fcm reaktif g\u00fc\u00e7 uygulamalar\u0131 i\u00e7in uygun mu?<\/h3>\n<p>Hay\u0131r. Uygunluk, elektrik sistemi, gereken yan\u0131t, y\u00fck profili, mevcut ekipman ve proje gereksinimlerine ba\u011fl\u0131d\u0131r.<\/p>\n<h3>Bu sitede \u201cASVG\u201d ne anlama geliyor?<\/h3>\n<p>Bu, CNBYG\u2019nin Geli\u015fmi\u015f Statik Reaktif G\u00fc\u00e7 Jenerat\u00f6r\u00fc \u00fcr\u00fcn terminolojisidir. \u0130\u015flevleri ve yap\u0131land\u0131rmay\u0131 ilgili \u00fcr\u00fcn dok\u00fcmantasyonu ve uygulama verileriyle do\u011frulay\u0131n.<\/p>\n<\/section>\n<p><!-- CNBYG-HUB-RESOURCES-END --><\/p>","protected":false},"excerpt":{"rendered":"<p>Statik reaktif g\u00fc\u00e7 kompansat\u00f6rlerimiz (SVG), \u00e7e\u015fitli end\u00fcstriyel uygulamalarda \u015febeke stabilitesi, g\u00fc\u00e7 fakt\u00f6r\u00fc ve reaktif g\u00fc\u00e7 talebi ile ilgili sorunlara en uygun \u00e7\u00f6z\u00fcm\u00fc sa\u011flar. Cihazlar son derece h\u0131zl\u0131 \u00e7al\u0131\u015fma, kompakt tasar\u0131m ve \u00fcst\u00fcn maliyet etkinli\u011fi \u00f6zelliklerine sahiptir, orta ve d\u00fc\u015f\u00fck voltaj g\u00fc\u00e7 sistemlerindeki bozukluklara an\u0131nda yan\u0131t verir. Reaktif g\u00fcc\u00fc kompans ederek, tesislerin \u00f6mr\u00fcn\u00fc \u00f6nemli \u00f6l\u00e7\u00fcde uzat\u0131r, \u00fcretim s\u00fcre\u00e7lerinin g\u00fcvenilirli\u011fini art\u0131r\u0131r, sistem performans\u0131n\u0131 iyile\u015ftirir ve iletim kay\u0131plar\u0131n\u0131 azalt\u0131r; t\u00fcm bunlar\u0131 en kat\u0131 enerji kalitesi standartlar\u0131n\u0131 kar\u015f\u0131layarak yapar.<\/p>","protected":false},"featured_media":1313,"template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[33,30],"product_tag":[],"class_list":["post-1291","product","type-product","status-publish","has-post-thumbnail","product_cat-power-quality-system","product_cat-products","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product\/1291","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/media\/1313"}],"wp:attachment":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/media?parent=1291"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product_brand?post=1291"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product_cat?post=1291"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product_tag?post=1291"}],"curies":[{"name":"Naber","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}