{"id":1293,"date":"2026-04-29T10:02:18","date_gmt":"2026-04-29T02:02:18","guid":{"rendered":"https:\/\/w6pown520g.wpdns.site\/?post_type=product&#038;p=1293"},"modified":"2026-06-29T15:33:02","modified_gmt":"2026-06-29T07:33:02","slug":"by82j-series-anti-harmonic-intelligent-capacitors","status":"publish","type":"product","link":"https:\/\/cnbygele.com\/tr\/product\/by82j-series-anti-harmonic-intelligent-capacitors\/","title":{"rendered":"BY82J Serisi Harmonik \u00d6nleyici Ak\u0131ll\u0131 Kondansat\u00f6rler"},"content":{"rendered":"<h2>\u00dcr\u00fcn A\u00e7\u0131klamas\u0131<\/h2>\n<p>Bu \u00fcr\u00fcnler, al\u00e7ak gerilim reaktif g\u00fc\u00e7 telafisi ve di\u011fer i\u015flevlere sahiptir; rezonans veya harmonik amplifikasyonu olmaks\u0131z\u0131n zorlu harmonik ortamlarda g\u00fcvenilir bir \u015fekilde \u00e7al\u0131\u015f\u0131r ve baz\u0131 harmonikleri emip ortadan kald\u0131rabilir. 7% serisi reakt\u00f6rlere sahip \u00fcr\u00fcnler 5. harmonik i\u00e7eren ortamlar i\u00e7in uygunken, 14% serisi reakt\u00f6rlere sahip \u00fcr\u00fcnler ise 3. harmonik i\u00e7eren ortamlar i\u00e7indir.<\/p>\n<h2><strong><b>\u00dcr\u00fcn\u00fcn temel \u00f6zellikleri<\/b><\/strong><\/h2>\n<ul>\n<li>Y\u00fcksek g\u00fcvenlikli, y\u00fcksek kaliteli end\u00fcstriyel al\u00e7ak gerilim filtreleme g\u00fc\u00e7 kondansat\u00f6rleri benimsemek;<\/li>\n<li>Senkron anahtar teknolojisi benimsenmi\u015f olup, geli\u015fmi\u015f teknolojiye ve istikrarl\u0131 ve g\u00fcvenilir performansa sahiptir;<\/li>\n<li>Kapal\u0131 devre benimsenmi\u015ftir; manyetik devre doymu\u015f durumda de\u011fildir, enerji t\u00fcketimi yoktur ve elektromanyetik radyasyon bulunmamaktad\u0131r;<\/li>\n<li>\u00d6zel teknolojiler ve s\u00fcre\u00e7ler benimseyerek, y\u00fcksek mertebeli harmonikleri ve kalk\u0131\u015f ak\u0131mlar\u0131n\u0131 etkili bir \u015fekilde bast\u0131rabilir ve 3-13 veya daha \u00fczeri harmoniklerin bast\u0131r\u0131lmas\u0131 \u00fczerinde belirgin bir etkiye sahiptir;<\/li>\n<li>Mod\u00fcler yap\u0131, esnek kombinasyon, kolay geni\u015fletilebilirlik, basit kurulum ve kolay bak\u0131m;<\/li>\n<li>Ak\u0131ll\u0131 a\u011f, 485 ileti\u015fim aray\u00fcz\u00fc, kapsaml\u0131 g\u00fc\u00e7 da\u011f\u0131t\u0131m y\u00f6netimi i\u00e7in arka u\u00e7 bilgisayara ba\u011flanabilir;<\/li>\n<li>Merkeziyetsiz kontrol modu benimsenmi\u015ftir, 1 milyon hatas\u0131z anahtarlama ile y\u00fcksek g\u00fcvenilirlik;<\/li>\n<li>Aray\u00fcz \u00c7ince olarak g\u00f6r\u00fcnt\u00fclenir; basit kullan\u0131m\u0131 ve kolay bak\u0131m\u0131 sayesinde sahadaki ar\u0131zalar\u0131n tespitini kolayla\u015ft\u0131r\u0131r.;<\/li>\n<li>\u015eiddetli harmonik durumlar\u0131nda \u00e7al\u0131\u015fma g\u00fcvenilirli\u011fini art\u0131rmak i\u00e7in i\u00e7ine SH patlamaya dayan\u0131kl\u0131 cihaz ve s\u0131cakl\u0131k kontrol cihaz\u0131 ekleyin;<\/li>\n<li>Enerji tasarrufu etkisi belirgindir; g\u00fc\u00e7 fakt\u00f6r\u00fcn\u00fc etkin bir \u015fekilde iyile\u015ftirir, g\u00fc\u00e7 t\u00fcketimini azalt\u0131r ve g\u00fc\u00e7 kalitesini art\u0131r\u0131r.<\/li>\n<\/ul>\n<h2>\u00dcr\u00fcn\u00fcn Teknik G\u00f6stergeleri<\/h2>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"252\">Proje<\/td>\n<td width=\"408\">Parametre<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"7\" width=\"89\">G\u00fc\u00e7<br \/>\ntedarik<br \/>\nko\u015fullar<\/td>\n<td>Anma gerilimi<\/td>\n<td>~220V\/380V<\/td>\n<\/tr>\n<tr>\n<td>Gerilim sapmas\u0131<\/td>\n<td>\u00b120%<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Gerilim dalga formu<\/td>\n<td>Harmonikler \u2264 5%<\/td>\n<\/tr>\n<tr>\n<td>Sin\u00fcs dalgas\u0131, toplam bozulma oran\u0131 \u2264 5%<\/td>\n<\/tr>\n<tr>\n<td>\u015eebeke frekans\u0131<\/td>\n<td>48,5-51,5 Hz<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">G\u00fc\u00e7 t\u00fcketimi<\/td>\n<td>&lt;1W(Kondansat\u00f6r kesilirken)<\/td>\n<\/tr>\n<tr>\n<td>(\u0130ki kondansat\u00f6r yat\u0131r\u0131m yaparken)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" width=\"89\">\u00d6l\u00e7\u00fcm<br \/>\nve hata<\/td>\n<td>Voltaj<\/td>\n<td>\u22640,5%<\/td>\n<\/tr>\n<tr>\n<td>G\u00fcncel<\/td>\n<td>\u22641%<\/td>\n<\/tr>\n<tr>\n<td>G\u00fc\u00e7 fakt\u00f6r\u00fc<\/td>\n<td>\u2264\u00b11,5%<\/td>\n<\/tr>\n<tr>\n<td>S\u0131cakl\u0131k<\/td>\n<td>\u00b11\u2103<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" width=\"89\">Koruma<br \/>\nhata<\/td>\n<td>Voltaj<\/td>\n<td>\u22640,5%<\/td>\n<\/tr>\n<tr>\n<td>G\u00fcncel<\/td>\n<td>\u22641%<\/td>\n<\/tr>\n<tr>\n<td>S\u0131cakl\u0131k<\/td>\n<td>\u00b11\u2103<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" width=\"89\">\u00c7evre<br \/>\nko\u015ful<\/td>\n<td>Ortam s\u0131cakl\u0131\u011f\u0131<\/td>\n<td>-40\u2103 ile +40\u2103 aras\u0131<\/td>\n<\/tr>\n<tr>\n<td>Ba\u011f\u0131l nem<\/td>\n<td>40 \u2103, 20-90%<\/td>\n<\/tr>\n<tr>\n<td>\u0130rtifa<\/td>\n<td>&lt;2000m<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"89\">G\u00fcvenilirlik<br \/>\nparametreler<\/td>\n<td>Kontrol do\u011frulu\u011fu<\/td>\n<td>100%<\/td>\n<\/tr>\n<tr>\n<td>\u0130zin verilen frekans\u0131 kontrol et<\/td>\n<td>2 milyon kez<\/td>\n<\/tr>\n<tr>\n<td width=\"89\">Elektrik<br \/>\ng\u00fcvenlik<\/td>\n<td colspan=\"2\" width=\"572\">Elektriksel a\u00e7\u0131kl\u0131k ve y\u00fczeysel ka\u00e7ak yolu mesafesi, yal\u0131t\u0131m dayan\u0131m\u0131, emniyet korumas\u0131, k\u0131sa devre<br \/>\nizolasyon, adaptasyon ve kontrol devresi korumas\u0131, ilgili maddelere tam olarak uygundur<br \/>\n\u00c7in elektrik end\u00fcstrisi standard\u0131 DL\/T842-2003 \"Al\u00e7ak Gerilim \u015e\u00f6nt Kondansat\u00f6rleri Kullan\u0131m Ko\u015fullar\u0131\"<br \/>\nCihazlar\u0131\u201d ve GBT22582-2008 \u201dAl\u00e7ak Gerilim G\u00fc\u00e7 Kondansat\u00f6rleri i\u00e7in G\u00fc\u00e7 Fakt\u00f6r\u00fc D\u00fczeltme Cihazlar\u0131\u201d.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>T\u00fcm Makinenin \u00c7al\u0131\u015fma Prensibi<\/h2>\n<p>\u00dcr\u00fcn; ak\u0131ll\u0131 bile\u015fenlerden, s\u0131f\u0131r ge\u00e7i\u015fli anahtarlardan, ak\u0131m \u00f6rneklemeden, s\u0131cakl\u0131k \u00f6rneklemeden, dny serisi reakt\u00f6rlerden ve al\u00e7ak gerilim filtreleme g\u00fc\u00e7 kondansat\u00f6rlerinden olu\u015fur. A\u015fa\u011f\u0131daki \u015fekil, \u00fcr\u00fcn serisindeki faz ayarl\u0131 kompanzasyon y\u00f6ntemine ait \u00fcr\u00fcn\u00fcn \u00e7al\u0131\u015fma prensibi blok \u015femas\u0131d\u0131r.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-992\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/7.BY82.webp\" alt=\"\" width=\"1920\" height=\"1449\" \/><\/p>\n<h2>Her Bir Bile\u015fenin \u00c7al\u0131\u015fma Prensibi<\/h2>\n<p><strong>Ak\u0131ll\u0131 bile\u015fenler<\/strong><\/p>\n<p>Geni\u015f s\u0131cakl\u0131k aral\u0131\u011f\u0131na sahip end\u00fcstriyel s\u0131n\u0131f elektronik bile\u015fenler kullan\u0131r, zorlu ortamlara uyum sa\u011flar ve uzun s\u00fcre kararl\u0131 bir \u015fekilde \u00e7al\u0131\u015f\u0131r.<\/p>\n<p><strong>E\u015fzamanl\u0131 anahtar<\/strong><\/p>\n<p>Mekanik kontakt\u00f6rlerin ve benzeri bile\u015fenlerin \u00f6zellikleri entegre edilerek ba\u011f\u0131ms\u0131z olarak geli\u015ftirilen bu sistem, s\u0131f\u0131r ge\u00e7i\u015fli anahtarlama ger\u00e7ekle\u015ftirmek \u00fczere mikroelektronik teknoloji ile mekanik kontaklar\u0131 kontrol eder; b\u00f6ylece kalk\u0131\u015f ak\u0131m\u0131 darbesini \u00f6nler, kay\u0131plar\u0131 azalt\u0131r ve kondansat\u00f6r \u00f6mr\u00fcn\u00fc uzat\u0131r.<\/p>\n<p><strong>Kuru tip seri reakt\u00f6r<\/strong><\/p>\n<p>Y\u00fcksek ak\u0131l\u0131 ithal malzemelerden \u00fcretilmi\u015f; hafif, k\u00fc\u00e7\u00fck, d\u00fc\u015f\u00fck kay\u0131pl\u0131, d\u00fc\u015f\u00fck s\u0131cakl\u0131k art\u0131\u015f\u0131 ve g\u00fcr\u00fclt\u00fcs\u00fcne sahip; a\u015f\u0131r\u0131 s\u0131cakl\u0131k durumunda sinyal g\u00f6nderen dahili termal r\u00f6le.<\/p>\n<p><strong>Mini ak\u0131m \u00f6rnekleme transformat\u00f6r\u00fc<\/strong><\/p>\n<p>Permalloy \u00e7ekirdek, y\u00fcksek do\u011frusall\u0131k ve iyi frekans karakteristikleri ile do\u011fru ve kararl\u0131 ak\u0131m ile koruma sa\u011flar.<\/p>\n<p><strong>H\u0131zl\u0131 devre kesici<\/strong><\/p>\n<p>Kal\u0131pl\u0131 devre kesici tipinde, anma ak\u0131m\u0131n\u0131n 10 kat\u0131nda 100 ms i\u00e7inde a\u00e7ma yapan, ana koruma ve g\u00fc\u00e7 anahtar\u0131 olarak i\u015flev g\u00f6ren.<\/p>\n<h2>G\u00f6r\u00fcn\u00fcm ve Kurulum Boyutlar\u0131<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-993\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/8.BY82.webp\" alt=\"\" width=\"1920\" height=\"599\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"162\">Kondansat\u00f6r modeli<\/td>\n<td width=\"72\">Kapasite<\/td>\n<td width=\"72\">H(mm)<\/td>\n<td width=\"157\">Kondansat\u00f6r modeli<\/td>\n<td width=\"72\">Kapasite<\/td>\n<td width=\"72\">H(mm)<\/td>\n<\/tr>\n<tr>\n<td>BY82JS\/480-50\/P7<\/td>\n<td width=\"72\">50<\/td>\n<td>485<\/td>\n<td>BY82JF\/280-40\/P7<\/td>\n<td>40<\/td>\n<td>425<\/td>\n<\/tr>\n<tr>\n<td>BY82JS\/480-40\/P7<\/td>\n<td>40<\/td>\n<td>425<\/td>\n<td>BY82JF\/280-30\/P7<\/td>\n<td>30<\/td>\n<td>425<\/td>\n<\/tr>\n<tr>\n<td>BY82JS\/480-30\/P7<\/td>\n<td>30<\/td>\n<td>425<\/td>\n<td>BY82JF\/280-20\/P7<\/td>\n<td>20<\/td>\n<td>385<\/td>\n<\/tr>\n<tr>\n<td>BY82JS\/480-25\/P7<\/td>\n<td>25<\/td>\n<td>425<\/td>\n<td>BY82JF\/280-10\/P7<\/td>\n<td>10<\/td>\n<td>385<\/td>\n<\/tr>\n<tr>\n<td>BY82JS\/480-20\/P7<\/td>\n<td>20<\/td>\n<td>385<\/td>\n<td>BY82JS\/480-25+25<\/td>\n<td>25<\/td>\n<td>420<\/td>\n<\/tr>\n<tr>\n<td>BY82JS\/480-15\/P7<\/td>\n<td width=\"72\">15<\/td>\n<td>385<\/td>\n<td>BY82JS\/480-30+30<\/td>\n<td>30<\/td>\n<td>420<\/td>\n<\/tr>\n<tr>\n<td>BY82JS\/480-10\/P7<\/td>\n<td>10<\/td>\n<td>385<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Not: 1. Yukar\u0131daki \u00fcr\u00fcnler i\u00e7in standart reakt\u00f6r oranlar\u0131 P7 ve P14 olup, m\u00fc\u015fteri ihtiya\u00e7lar\u0131na g\u00f6re di\u011fer reakt\u00f6r oranlar\u0131 se\u00e7ilebilir.<\/p>\n<ol start=\"2\">\n<li>Tabloda yaln\u0131zca yayg\u0131n olarak kullan\u0131lan \u00fcr\u00fcn modelleri ve teknik \u00f6zellikler listelenmi\u015ftir, di\u011fer modeller i\u00e7in detaylar sorulabilir.<\/li>\n<li>P14 kompanzasyon tipi \u00fcr\u00fcn\u00fcn anma gerilimi 525V, alt kompanzasyon tipi \u00fcr\u00fcn\u00fcn anma gerilimi ise 300V'dir.<\/li>\n<\/ol>\n<h2>Basit Harmonik Kar\u015f\u0131t\u0131 Ak\u0131ll\u0131 Kondansat\u00f6r<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-994\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/9.BY82.webp\" alt=\"\" width=\"1592\" height=\"574\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"251\">Tazminat y\u00f6ntemi<\/td>\n<td width=\"211\">Model<\/td>\n<td width=\"145\">H(mm)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\">\u00dc\u00e7 fazl\u0131 kompanzasyon<\/td>\n<td>BY82DS\/480-40<\/td>\n<td>405<\/td>\n<\/tr>\n<tr>\n<td>BY82DS\/480-30<\/td>\n<td>375<\/td>\n<\/tr>\n<tr>\n<td>BY82DS\/480-20<\/td>\n<td>355<\/td>\n<\/tr>\n<tr>\n<td>BY82DS\/480-10<\/td>\n<td>355<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\u00dc\u00e7 fazl\u0131 kompanzasyon<\/td>\n<td>BY82DF\/280-30<\/td>\n<td>405<\/td>\n<\/tr>\n<tr>\n<td>BY82DF\/280-20<\/td>\n<td>355<\/td>\n<\/tr>\n<tr>\n<td>BY82DF\/280-10<\/td>\n<td>355<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Not: Ak\u0131ll\u0131 kondansat\u00f6rlerin geni\u015fli\u011fi ve derinli\u011fi farkl\u0131 kapasiteler aras\u0131nda tutarl\u0131d\u0131r, ancak yaln\u0131zca y\u00fcksekliklerinde farkl\u0131l\u0131klar vard\u0131r.<\/p>\n<h2>\u00c7evrimi\u00e7i Ekler<\/h2>\n<p><strong>Rs-485 \u00c7evrimi\u00e7i Konnekt\u00f6r<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"32\">Hay\u0131r.<\/td>\n<td width=\"51\">T\u00fcr<\/td>\n<td width=\"50\">Uzunluk<\/td>\n<td width=\"206\">Fiziksel foto\u011fraflar<\/td>\n<td width=\"329\">Ama\u00e7<\/td>\n<\/tr>\n<tr>\n<td>1<\/td>\n<td>A Tipi<\/td>\n<td>30 cm<\/td>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1003\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/10.BY82-1.webp\" alt=\"\" width=\"450\" height=\"179\" \/><\/td>\n<td>Birbirine biti\u015fik iki \u00fcr\u00fcn\u00fc birbirine ba\u011flamak i\u00e7in kullan\u0131l\u0131r<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>B Tipi<\/td>\n<td>80 cm<\/td>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1002\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/11.BY82-1.webp\" alt=\"\" width=\"442\" height=\"182\" \/><\/td>\n<td width=\"329\">\u00dcr\u00fcnleri birbirine ba\u011flamak i\u00e7in kullan\u0131l\u0131r<br \/>\nalt ve \u00fcst katlar aras\u0131nda<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Type-C<\/td>\n<td>260 cm<\/td>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-997\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/12.BY82.webp\" alt=\"\" width=\"466\" height=\"197\" \/><\/td>\n<td width=\"329\">Ana ve yard\u0131mc\u0131 dolaplar aras\u0131ndaki ba\u011flant\u0131 i\u00e7in kullan\u0131l\u0131r.,<br \/>\ndenetleyiciler, durum g\u00f6stergesi \u00fcr\u00fcnleri ve \u00fcr\u00fcnler<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-998\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/13.BY82.webp\" alt=\"\" width=\"1920\" height=\"650\" \/><\/p>\n<h2>Elektrik Tesisat\u0131 Gereksinimleri<\/h2>\n<p>G\u00fc\u00e7 kablosunun \u00fcretimi \u015fekilde g\u00f6sterildi\u011fi gibidir: g\u00fc\u00e7 kablosu vidalarla s\u0131k\u0131lmal\u0131 ve \u00e7ok sa\u011flam oldu\u011funu kan\u0131tlamak i\u00e7in g\u00fc\u00e7 kablosu kuvvetle \u00e7ekilmelidir. Aksi takdirde, b\u00f6lgede a\u015f\u0131r\u0131 \u0131s\u0131nmaya neden olur ve \u00fcr\u00fcne zarar verir.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-999\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/14.BY82.webp\" alt=\"\" width=\"1920\" height=\"735\" \/><\/p>\n<p>Kontrol\u00f6r ve \u00fcr\u00fcn kablolamas\u0131: \u0130kincil kablolaman\u0131n, kabin \u00fcr\u00fcn\u00fcndeki ilk veya son harici 485 ba\u011flant\u0131 noktas\u0131ndan ilgili kontrol\u00f6r 485 ba\u011flant\u0131 noktas\u0131na ba\u011flanmas\u0131 gerekir; \u015eekilde g\u00f6sterildi\u011fi gibi:<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1000\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/15.BY82.webp\" alt=\"\" width=\"1920\" height=\"503\" \/><\/p>\n<p>Harici bir ikaz lambas\u0131 oldu\u011funda, kondansat\u00f6r modeline g\u00f6re uygun voltaj seviyesi durum ikaz lambas\u0131n\u0131 se\u00e7in; telafi kondansat\u00f6r\u00fcn\u00fcn ikaz lambas\u0131 380V'tur: Telafi kondansat\u00f6r\u00fcn\u00fcn ikaz lambas\u0131 220V'tur ve telafi kondansat\u00f6r\u00fcn\u00fcn 5 numaral\u0131 terminali bir ikaz lambas\u0131na ba\u011flan\u0131r. Lamban\u0131n di\u011fer ucu UB g\u00fc\u00e7 kayna\u011f\u0131na ba\u011flanmal\u0131d\u0131r; Telafi kondansat\u00f6r\u00fcn\u00fcn 3, 4 ve 5 numaral\u0131 terminalleri s\u0131ras\u0131yla ikaz lambas\u0131na ba\u011flanmal\u0131 ve lamban\u0131n di\u011fer ucu n\u00f6tr hatta UN ba\u011flanmal\u0131d\u0131r (\u00fcr\u00fcn ikaz lambalar\u0131 k\u0131sa devre yapt\u0131r\u0131lamaz veya ortak kullan\u0131lamaz).<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1001\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/16.BY82.webp\" alt=\"\" width=\"1920\" height=\"499\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>BY82J serisi harmonik \u00f6nleyici ak\u0131ll\u0131 kondansat\u00f6rler; temel olarak \u00fc\u00e7gen veya y\u0131ld\u0131z tip piezoelektrik kondansat\u00f6rlerden olu\u015fan, zeka i\u00e7in bir\u00e7ok yeni teknolojiyi entegre eden \u00fcr\u00fcnlerdir. Kimya sanayi ve elektrik g\u00fcc\u00fc gibi end\u00fcstriyel alanlar\u0131n yan\u0131 s\u0131ra ileti\u015fim ve sa\u011fl\u0131k hizmetleri gibi ticari g\u00fc\u00e7 sistemlerinde yayg\u0131n olarak kullan\u0131lmaktad\u0131rlar.<\/p>","protected":false},"featured_media":1326,"template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[36,35],"product_tag":[],"class_list":["post-1293","product","type-product","status-publish","has-post-thumbnail","product_cat-intelligent-capacitor","product_cat-reactive-power-compensator","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product\/1293","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/media\/1326"}],"wp:attachment":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/media?parent=1293"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product_brand?post=1293"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product_cat?post=1293"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product_tag?post=1293"}],"curies":[{"name":"Naber","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}