{"id":1295,"date":"2026-04-29T10:02:18","date_gmt":"2026-04-29T02:02:18","guid":{"rendered":"https:\/\/w6pown520g.wpdns.site\/?post_type=product&#038;p=1295"},"modified":"2026-06-29T15:27:43","modified_gmt":"2026-06-29T07:27:43","slug":"by83-series-intelligent-capacitor-controller","status":"publish","type":"product","link":"https:\/\/cnbygele.com\/tr\/product\/by83-series-intelligent-capacitor-controller\/","title":{"rendered":"BY83 Serisi Ak\u0131ll\u0131 Kondansat\u00f6r Kontrol Cihaz\u0131"},"content":{"rendered":"<h2>\u00dcr\u00fcn A\u00e7\u0131klamas\u0131<\/h2>\n<p>BY83 serisi ak\u0131ll\u0131 kondansat\u00f6r kontrol\u00f6r\u00fc tam fonksiyonelli\u011fe, esnek montaja, T\u00fcrk\u00e7e men\u00fc g\u00f6stergesine ve kolay kullan\u0131m\u0131na sahiptir; firmam\u0131z taraf\u0131ndan \u00fcretilen BY81 serisi ak\u0131ll\u0131 kondansat\u00f6rler, BY82 serisi harmonik filtreli ak\u0131ll\u0131 kondansat\u00f6rler, BY86 serisi kontroll\u00fc ak\u0131ll\u0131 kondansat\u00f6rler ve kompakt \u015falterli BY89 serisi ak\u0131ll\u0131 kondansat\u00f6rler ile birlikte kullan\u0131labilir. Bu \u00fcr\u00fcn\u00fcn kullan\u0131lmas\u0131; mevcut al\u00e7ak gerilim reaktif g\u00fc\u00e7 kompanzasyon panosunu bir voltmetre, bir gerilim \u00f6l\u00e7\u00fcm kom\u00fctat\u00f6r\u00fc, bir g\u00fc\u00e7 fakt\u00f6r\u00fc \u00f6l\u00e7er, \u00fc\u00e7 ampermetre, bir al\u00e7ak gerilim reaktif g\u00fc\u00e7 bireysel kompanzasyon kontrol yede\u011fi ve t\u00fcm kondansat\u00f6r durum g\u00f6sterge \u0131\u015f\u0131klar\u0131n\u0131n yerini alarak son derece basit hale getirebilir ve \u00e7ok fazla kablolamadan tasarruf sa\u011flayabilir.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1023\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/5.BY83.webp\" alt=\"\" width=\"1574\" height=\"1272\" \/><\/p>\n<h2>\u00dcr\u00fcn\u00fcn Teknik G\u00f6stergeleri<\/h2>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"372\">Proje<\/td>\n<td width=\"260\">Parametre<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\">\u00c7al\u0131\u015fma ortam\u0131<\/td>\n<td>Ortam s\u0131cakl\u0131\u011f\u0131<\/td>\n<td>-40\u2103~+55\u2103<\/td>\n<\/tr>\n<tr>\n<td>Ba\u011f\u0131l nem<\/td>\n<td>40 \u2103\u2019de 20%~90%<\/td>\n<\/tr>\n<tr>\n<td>Atmosfer bas\u0131nc\u0131<\/td>\n<td>79.5-106.0 kPa<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">\u00c7al\u0131\u015fan g\u00fc\u00e7 kayna\u011f\u0131<\/td>\n<td>\u00c7al\u0131\u015fma voltaj\u0131<\/td>\n<td>AC 50 Hz, 380 V \u00b1 201 TP3T<\/td>\n<\/tr>\n<tr>\n<td>Fonksiyon t\u00fcketimi<\/td>\n<td>&lt;30VA<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"5\">\u00d6l\u00e7\u00fcm do\u011frulu\u011fu<\/td>\n<td>Voltaj<\/td>\n<td>Seviye 0.5<\/td>\n<\/tr>\n<tr>\n<td>G\u00fcncel<\/td>\n<td>Seviye 0.5<\/td>\n<\/tr>\n<tr>\n<td>G\u00fc\u00e7 fakt\u00f6r\u00fc<\/td>\n<td>Seviye 1.0<\/td>\n<\/tr>\n<tr>\n<td>Reaktif g\u00fc\u00e7<\/td>\n<td>Seviye 1.0<\/td>\n<\/tr>\n<tr>\n<td>G\u00fc\u00e7 fakt\u00f6r\u00fc<\/td>\n<td>\u00b10,01<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Kontrol do\u011frulu\u011fu<\/td>\n<td>G\u00fc\u00e7 fakt\u00f6r\u00fc<\/td>\n<td>\u00b10,01<\/td>\n<\/tr>\n<tr>\n<td>Reaktif g\u00fc\u00e7<\/td>\n<td>+120%of minimum kondansat\u00f6r kapasitesi<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Mekanik parametreler<\/td>\n<td>Genel boyutlar (GxYxD)<\/td>\n<td>120x120x95mm<\/td>\n<\/tr>\n<tr>\n<td>A\u00e7\u0131kl\u0131k boyutu (G x Y)<\/td>\n<td>113x113 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Kablo \u015eemas\u0131<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1024\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.BY83.webp\" alt=\"\" width=\"1920\" height=\"741\" \/><\/p>\n<p><strong>Denetleyicinin elektrik kablo terminalleri \u015fekilde g\u00f6sterildi\u011fi gibi tan\u0131mlanm\u0131\u015ft\u0131r:<\/strong><\/p>\n<p>Kontrol cihaz\u0131n\u0131 monte ederken kablolama i\u00e7in arka panelin elektrik \u015fematik diyagram\u0131na ba\u015fvurun.<\/p>\n<p>Spesifik kablolama y\u00f6ntemi \u015f\u00f6yledir:<\/p>\n<p>UA, UB ve UC s\u0131ras\u0131yla A, B ve C \u00fc\u00e7 fazl\u0131 gerilimlerine ba\u011flan\u0131rken, UN n\u00f6tr hatt\u0131na ba\u011flan\u0131r:<\/p>\n<p>La+, la -, lb+, lb -, Ic+ ve Ic - s\u0131ras\u0131yla A, B ve C \u00fc\u00e7 fazl\u0131 ak\u0131mlar\u0131na ba\u011flanm\u0131\u015ft\u0131r;<\/p>\n<p>A. B, al\u00e7ak gerilim ak\u0131ll\u0131 kondansat\u00f6r\u00fcn ileti\u015fim portuna ba\u011flanabilen bir RS485 ileti\u015fim aray\u00fcz\u00fcd\u00fcr.<\/p>\n<p>Not: T\u00fcm ak\u0131ll\u0131 kondansat\u00f6rler ortak kompanzasyon kondansat\u00f6rleri oldu\u011funda, B faz\u0131 ak\u0131m hatt\u0131na yaln\u0131zca Ib+ ve Ib \u2013 ba\u011flanabilir.<\/p>\n<h2>Kablo Ba\u011flant\u0131 Terminallerini Kullanma Talimatlar\u0131<\/h2>\n<table>\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"274\">Proje<\/td>\n<td width=\"389\">Parametre<\/td>\n<\/tr>\n<tr>\n<td width=\"50\">10 mm\u00b2<\/td>\n<td width=\"223\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1025\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/7.BY83.webp\" alt=\"\" width=\"450\" height=\"225\" \/><\/td>\n<td width=\"389\">10\u339f iletken i\u00e7in (30Kvar alt\u0131ndaki tekli kondansat\u00f6r kapasitesi)<\/td>\n<\/tr>\n<tr>\n<td width=\"50\">16 mm\u00b2<\/td>\n<td width=\"223\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1026\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/8.BY83.webp\" alt=\"\" width=\"450\" height=\"217\" \/><\/td>\n<td width=\"389\">16\u339f iletken i\u00e7in (Tekli kondansat\u00f6r g\u00fcc\u00fc 30 Kvar alt\u0131nda)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Rs485 \u0130leti\u015fim Kablosu Kullan\u0131m Talimatlar\u0131<\/h2>\n<table>\n<tbody>\n<tr>\n<td width=\"94\">Teknik \u00d6zellikler<\/td>\n<td width=\"300\">Resim<\/td>\n<td width=\"273\">Ama\u00e7<\/td>\n<\/tr>\n<tr>\n<td>0,5 m<\/td>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1027\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/9.BY83.webp\" alt=\"\" width=\"478\" height=\"168\" \/><\/td>\n<td>Birbirine biti\u015fik iki \u00fcr\u00fcn\u00fc birbirine ba\u011flamak i\u00e7in kullan\u0131l\u0131r<\/td>\n<\/tr>\n<tr>\n<td>0,8 m<\/td>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1028\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/10.BY83.webp\" alt=\"\" width=\"478\" height=\"176\" \/><\/td>\n<td width=\"273\">\u00dcr\u00fcnleri birbirine ba\u011flamak i\u00e7in kullan\u0131l\u0131r<br \/>\n\u00fcst ve alt katlar<\/td>\n<\/tr>\n<tr>\n<td>2,6 milyon<\/td>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1029\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/11.BY83.webp\" alt=\"\" width=\"478\" height=\"199\" \/><\/td>\n<td width=\"273\">Ana ve aras\u0131ndaki ba\u011flant\u0131 i\u00e7in kullan\u0131l\u0131r<br \/>\nyard\u0131mc\u0131 dolaplar, kontrol\u00f6rler, durum<br \/>\nbelirti \u00fcr\u00fcnleri ve \u00fcr\u00fcnler<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>BY83 serisi ak\u0131ll\u0131 kondansat\u00f6r kontrol cihaz\u0131; Ak\u0131m Trafosu (CT) oran\u0131 ayar\u0131, koruma ayar\u0131, gecikme s\u00fcresi ayar\u0131 ve g\u00fc\u00e7 fakt\u00f6r\u00fc ayar\u0131 dahil olmak \u00fczere \u00e7e\u015fitli ayar fonksiyonlar\u0131 sunar. Kontrol fonksiyonlar\u0131 hem otomatik hem de manuel kontrol\u00fc destekler ve kontrol edilen fiziksel b\u00fcy\u00fckl\u00fcklere (reaktif g\u00fc\u00e7, reaktif ak\u0131m, g\u00fc\u00e7 fakt\u00f6r\u00fc ve zaman aral\u0131\u011f\u0131 gibi) g\u00f6re kontrol\u00fc otomatik olarak de\u011fi\u015ftirebilir. Ayn\u0131 kapasitedeki kondansat\u00f6rler d\u00f6ng\u00fcsel anahtarlama ile kontrol edilirken, farkl\u0131 kapasitelerdeki kondansat\u00f6rler reaktif g\u00fc\u00e7 se\u00e7imine g\u00f6re kontrol edilir. Kondansat\u00f6rleri devreye al\u0131p \u00e7\u0131kar-madan \u00f6nce sistem, anahtarlama sonucunda olu\u015facak reaktif g\u00fc\u00e7 ve gerilim de\u011fi\u015fikliklerini \u00f6ng\u00f6r\u00fcr; anahtarlama sonras\u0131nda ters i\u015flem bekleniyorsa anahtarlama kontrol\u00fc ger\u00e7ekle\u015ftirilmez.<\/p>","protected":false},"featured_media":1619,"template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[37,35],"product_tag":[],"class_list":["post-1295","product","type-product","status-publish","has-post-thumbnail","product_cat-intelligent-controller","product_cat-reactive-power-compensator","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product\/1295","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/media\/1619"}],"wp:attachment":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/media?parent=1295"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product_brand?post=1295"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product_cat?post=1295"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product_tag?post=1295"}],"curies":[{"name":"Naber","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}