{"id":1296,"date":"2026-04-29T10:02:18","date_gmt":"2026-04-29T02:02:18","guid":{"rendered":"https:\/\/w6pown520g.wpdns.site\/?post_type=product&#038;p=1296"},"modified":"2026-10-23T09:56:54","modified_gmt":"2026-10-23T01:56:54","slug":"jkw-series-reactive-power-automatic-compensation-controller","status":"publish","type":"product","link":"https:\/\/cnbygele.com\/tr\/product\/jkw-series-reactive-power-automatic-compensation-controller\/","title":{"rendered":"JKW Serisi Reaktif G\u00fc\u00e7 Otomatik Kompansazyon Kontrol Cihaz\u0131"},"content":{"rendered":"<h2>Sipari\u015f Vermeden \u00d6nce Do\u011fru JKW Kontrol\u00f6r\u00fcn\u00fc Se\u00e7in<\/h2>\n<p>Bu sayfada birden fazla kontrol\u00f6r modeli listelenmektedir. JKW ailesi ad\u0131n\u0131n ayn\u0131 olmas\u0131; panel boyutlar\u0131n\u0131n, besleme \u00f6zelliklerinin, \u00e7\u0131k\u0131\u015flar\u0131n veya anahtarlama davran\u0131\u015flar\u0131n\u0131n ayn\u0131 oldu\u011fu anlam\u0131na gelmez. Tam sipari\u015f kodunu mevcut pano \u00e7izimi ve \u00fcreticinin g\u00fcncel kullan\u0131m k\u0131lavuzuyla kar\u015f\u0131la\u015ft\u0131r\u0131n.<\/p>\n<div style=\"overflow-x:auto;max-width:100%\">\n<table>\n<thead>\n<tr>\n<th>Kontrol edilecek \u00f6\u011fe<\/th>\n<th>Bilgi talebiyle birlikte g\u00f6nderilmesi gerekenler<\/th>\n<th>Birbiriyle uyumlu olmas\u0131 gereken \u00f6zellikler<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Model kimli\u011fi ve montaj uyumu<\/td>\n<td>Orijinal model etiketinin foto\u011fraf\u0131, panel kesim \u00f6l\u00e7\u00fcleri ve montaj derinli\u011fi<\/td>\n<td>Tam model kodu ve mekanik \u00e7izim<\/td>\n<\/tr>\n<tr>\n<td>Besleme ve ak\u0131m trafosu (CT) giri\u015fi<\/td>\n<td>Ger\u00e7ek besleme de\u011feri, CT oran\u0131, sekonder anma de\u011feri ve \u00f6rnekleme konumu<\/td>\n<td>Sipari\u015f edilen kontrol\u00f6r\u00fcn kullan\u0131m k\u0131lavuzu ve pano devre \u015femas\u0131<\/td>\n<\/tr>\n<tr>\n<td>Kademe ve \u00e7\u0131k\u0131\u015f \u00f6zellikleri<\/td>\n<td>Kademe say\u0131s\u0131, kondansat\u00f6r grubu kademe de\u011ferleri ve kontakt\u00f6r\/tist\u00f6r aray\u00fcz\u00fc<\/td>\n<td>\u00c7\u0131k\u0131\u015f t\u00fcr\u00fc ile anahtarlama ve de\u015farj gereksinimleri<\/td>\n<\/tr>\n<tr>\n<td>Yedek par\u00e7a uyumlulu\u011fu<\/td>\n<td>Mevcut terminal ba\u011flant\u0131 \u015femas\u0131, etkinle\u015ftirilmi\u015f i\u015flevler ve planlanan yedek model kodu<\/td>\n<td>Benzer model adlar\u0131na de\u011fil, belgelenmi\u015f uyumlulu\u011fa g\u00fcvenin<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>JKW-285 modeli i\u00e7in yedek \u00fcr\u00fcn talebinde, s\u00f6z konusu modele ait belgeleri sa\u011flay\u0131n: A\u015fa\u011f\u0131daki katalog sat\u0131rlar\u0131 tek ba\u015f\u0131na JKW-285 ile e\u015fde\u011ferli\u011fi kan\u0131tlamaz. Kontrol\u00f6r ayarlar\u0131n\u0131 yapmadan veya bir yedek \u00fcr\u00fcn\u00fc onaylamadan \u00f6nce belirsiz ya da tutars\u0131z eski kay\u0131tlar\u0131 g\u00fcncel tedarik\u00e7i teknik veri sayfas\u0131yla kar\u015f\u0131la\u015ft\u0131rarak do\u011frulay\u0131n.<\/p>\n<p>Sistem d\u00fczeyindeki ba\u011flam i\u00e7in \u015fu k\u0131lavuzlar\u0131 kullan\u0131n: <a href=\"https:\/\/cnbygele.com\/tr\/blog\/leading-vs-lagging-current-power-factor\/\">ileri ve geri g\u00fc\u00e7 fakt\u00f6r\u00fc k\u0131lavuzu<\/a> ve <a href=\"https:\/\/cnbygele.com\/tr\/blog\/static-var-generator-svg-capacity-selection-and-technical-parameter-guide\/\">reaktif kompanzasyon boyutland\u0131rma k\u0131lavuzu<\/a>. Kademeli kondansat\u00f6r bankas\u0131 kontrol cihaz\u0131 ile SVG farkl\u0131 i\u015flevlere sahiptir; bunlar\u0131 do\u011frudan birbirinin yerine kullan\u0131labilecek cihazlar olarak de\u011ferlendirmeyin.<\/p>\n<h2><strong><b>\u00dcr\u00fcn A\u00e7\u0131klamas\u0131<\/b><\/strong><\/h2>\n<p>JKW serisi reaktif g\u00fc\u00e7 otomatik kompanzasyon kontrol cihaz\u0131 (bundan sonra kontrol cihaz\u0131 olarak an\u0131lacakt\u0131r), al\u00e7ak gerilim da\u011f\u0131t\u0131m sistemlerinde reaktif g\u00fcc\u00fc kompanze etmek i\u00e7in kullan\u0131lan \u00f6zel bir ekipmand\u0131r. \u00c7in Halk Cumhuriyeti'nin JBT9663-2013 end\u00fcstri standard\u0131na ve DUT597-1996 elektrik enerjisi end\u00fcstrisi standard\u0131na uygun olarak tasarlanm\u0131\u015ft\u0131r. \u00d6rneklenen fiziksel b\u00fcy\u00fckl\u00fck reaktif g\u00fc\u00e7t\u00fcr. Yenilik\u00e7i tasar\u0131m\u0131, \u00e7oklu i\u015flevleri, iyi kontrol performans\u0131 ve y\u00fcksek g\u00fcvenilirli\u011fi sayesinde \u00c7in'deki benzer \u00fcr\u00fcnler aras\u0131nda \u00f6nc\u00fc bir konuma sahiptir ve da\u011f\u0131t\u0131m otomasyonu i\u00e7in yeni bir ekipman sunmaktad\u0131r.<\/p>\n<ul>\n<li>AC \u00f6rnekleme teknolojisi kullan\u0131r;<\/li>\n<li>Temel g\u00fc\u00e7 fakt\u00f6r\u00fcn\u00fc ve temel reaktif g\u00fcc\u00fc kontrol parametreleri olarak kullan\u0131r; y\u00fcksek kontrol hassasiyeti sa\u011flar, anahtarlama sal\u0131n\u0131m\u0131 olu\u015fturmaz ve harmoniklerden etkilenmez;<\/li>\n<li>Kontrol parametrelerinin tamam\u0131 dijital olarak ayarlan\u0131r; kullan\u0131m\u0131 kolayd\u0131r, ayarlar tek ad\u0131mda tamamlan\u0131r ve elektrik kesintilerinde veriler kaybolmaz;<\/li>\n<li>Anahtarlama s\u0131kl\u0131\u011f\u0131n\u0131 azaltmak ve sistemin hizmet \u00f6mr\u00fcn\u00fc uzatmak i\u00e7in otomatik optimizasyon kontrol\u00fc kullan\u0131r;<\/li>\n<li>G\u00fc\u00e7l\u00fc parazit \u00f6nleme kapasitesine sahiptir; g\u00fc\u00e7 kayna\u011f\u0131ndan do\u011frudan uygulanan 2000 V parazit darbelerine dayanabilir, donma veya veri kayb\u0131 ya\u015fanmadan kararl\u0131 ve g\u00fcvenilir \u015fekilde \u00e7al\u0131\u015f\u0131r;<\/li>\n<li>G\u00fc\u00e7 fakt\u00f6r\u00fcn\u00fcn, reaktif g\u00fcc\u00fcn, gerilimin, ak\u0131m\u0131n (primer taraf) ve \u015febeke kontrol parametrelerinin dijital g\u00f6sterimini sa\u011flar;<\/li>\n<li>\u0130ki \u00e7al\u0131\u015fma modu vard\u0131r: g\u00fc\u00e7 fakt\u00f6r\u00fc modu ve reaktif g\u00fc\u00e7 kontrol modu. Bu modlar kullan\u0131c\u0131lar\u0131n kurulum ve devreye alma i\u015flemlerini kolayla\u015ft\u0131r\u0131r;<\/li>\n<li>A\u015f\u0131r\u0131 gerilim ve d\u00fc\u015f\u00fck gerilimi alg\u0131lama ve g\u00f6r\u00fcnt\u00fcleme i\u015flevine sahiptir. Kondansat\u00f6r grubunun a\u015f\u0131r\u0131 gerilim ko\u015fullar\u0131nda \u00e7al\u0131\u015fmas\u0131n\u0131 \u00f6nlemek i\u00e7in kondansat\u00f6r grubunu h\u0131zla devreden \u00e7\u0131kar\u0131r;<\/li>\n<li>\u0130ste\u011fe ba\u011fl\u0131 anahtarlama sal\u0131n\u0131m\u0131 kilitleme i\u015flevine sahiptir (kullan\u0131c\u0131lar\u0131n sipari\u015f s\u0131ras\u0131nda bu \u00f6zelli\u011fi belirtmesi gerekir);<\/li>\n<li>Tek bir kondansat\u00f6r grubunun devreden \u00e7\u0131kar\u0131lmas\u0131ndan yeniden devreye al\u0131nmas\u0131na kadar ge\u00e7en s\u00fcreyi 200 saniye geciktirme i\u015flevi iste\u011fe ba\u011fl\u0131 olarak sunulur. Kondansat\u00f6r grubu devreden \u00e7\u0131kar\u0131ld\u0131ktan sonra yeterli de\u015farj s\u00fcresi sa\u011flanarak kondansat\u00f6rlerin yeniden devreye al\u0131nmas\u0131 s\u0131ras\u0131nda \u015febeke \u00fczerindeki etki azalt\u0131l\u0131r (kullan\u0131c\u0131lar\u0131n sipari\u015f s\u0131ras\u0131nda bu \u00f6zelli\u011fi belirtmesi gerekir);<\/li>\n<li>Ak\u0131m \u00f6rnekleme sinyalinin giri\u015f direnci 0,05 ohm'dan d\u00fc\u015f\u00fckt\u00fcr ve \u00f6l\u00e7\u00fcm devresinden do\u011frudan al\u0131nabilir;<\/li>\n<li>\u0130ki kompanzasyon modu vard\u0131r: g\u00fc\u00e7 fakt\u00f6r\u00fc ve reaktif g\u00fc\u00e7;<\/li>\n<li>Kullan\u0131m k\u0131lavuzu, kolay kurulum ve devreye alma i\u00e7in \u00e7ok say\u0131da ar\u0131za giderme y\u00f6ntemi sunar.<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1036\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/9.JKW_.webp\" alt=\"\" width=\"1566\" height=\"719\" \/><\/p>\n<h2><strong><b>Ana Teknik Parametreler <\/b><\/strong><\/h2>\n<p><strong>Temel Parametreler<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"298\">Proje<\/td>\n<td width=\"298\">Parametre<\/td>\n<\/tr>\n<tr>\n<td>Anma gerilimi<\/td>\n<td>AC380\/AC220V+10%<\/td>\n<\/tr>\n<tr>\n<td>Anma ak\u0131m\u0131<\/td>\n<td>AC0-5A<\/td>\n<\/tr>\n<tr>\n<td>Anma frekans\u0131<\/td>\n<td>50 Hz \u00b1 51 TP3T<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Kontrol Parametreleri<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"239\">Proje<\/td>\n<td width=\"413\">Parametre<\/td>\n<\/tr>\n<tr>\n<td>Hassasiyet<\/td>\n<td>100mA<\/td>\n<\/tr>\n<tr>\n<td>Hedef COS \u03a6 \u00f6n ayar\u0131<\/td>\n<td>0.70-1.00; Ad\u0131m boyutu 0.01; Fabrika \u00f6n ayar\u0131 0.95<\/td>\n<\/tr>\n<tr>\n<td>Anahtarlama gecikmesi<\/td>\n<td>1~!250s<\/td>\n<\/tr>\n<tr>\n<td>A\u015f\u0131r\u0131 gerilim korumas\u0131<\/td>\n<td>380~500\/230~260V; Ad\u0131m boyutu 1V; Geri d\u00f6n\u00fc\u015f fark\u0131 6V<\/td>\n<\/tr>\n<tr>\n<td>D\u00fc\u015f\u00fck voltaj korumas\u0131<\/td>\n<td>340V\/180V; Geri d\u00f6n\u00fc\u015f fark\u0131 6V<\/td>\n<\/tr>\n<tr>\n<td>Ak\u0131m trafosu de\u011fi\u015fiklikleri<\/td>\n<td>5015A~4000\/5A; Ad\u0131m boyutu 1<\/td>\n<\/tr>\n<tr>\n<td>Kapasitif kapasite<\/td>\n<td>0~125 kVAr, fabrika ayar\u0131 her kademe i\u00e7in 5 kVAr<\/td>\n<\/tr>\n<tr>\n<td>Kontak ak\u0131m de\u011feri<\/td>\n<td>Kademe ba\u015f\u0131na 380 V*5 A\/220 V*7 A<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>\u00d6l\u00e7\u00fcm Do\u011frulu\u011fu<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"298\">Proje<\/td>\n<td width=\"298\">Parametre<\/td>\n<\/tr>\n<tr>\n<td>Voltaj<\/td>\n<td>\u00b11,01 TP3T<\/td>\n<\/tr>\n<tr>\n<td>G\u00fcncel<\/td>\n<td>\u00b11,01 TP3T<\/td>\n<\/tr>\n<tr>\n<td>G\u00fc\u00e7 Fakt\u00f6r\u00fc<\/td>\n<td>\u00b11,01 TP3T<\/td>\n<\/tr>\n<tr>\n<td>Reaktif G\u00fc\u00e7<\/td>\n<td>\u00b12.0%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Kontrol Parametrelerinin Ayarlanabilir Aral\u0131\u011f\u0131 ve Fabrika Ayar De\u011ferleri<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"101\">Parametre kodu<\/td>\n<td width=\"246\">Anlam\u0131<\/td>\n<td width=\"170\">Ayar de\u011feri<\/td>\n<td width=\"146\">Ayarlanabilir aral\u0131k<\/td>\n<\/tr>\n<tr>\n<td>PA-1<\/td>\n<td>COS \u00f6n ayar\u0131<\/td>\n<td>Histerezis 0,95<\/td>\n<td>End\u00fcktif 0,8-100<\/td>\n<\/tr>\n<tr>\n<td>PA-2<\/td>\n<td>Gecikme \u00f6n ayar\u0131<\/td>\n<td>30 sn<\/td>\n<td>1-250 sn<\/td>\n<\/tr>\n<tr>\n<td>PA-3<\/td>\n<td>A\u015f\u0131r\u0131 gerilim \u00f6n ayar\u0131<\/td>\n<td>430V<\/td>\n<td>230~260V\/380~500V<\/td>\n<\/tr>\n<tr>\n<td>PA-4<\/td>\n<td>Devre \u00f6n ayar\u0131<\/td>\n<td>1-12<\/td>\n<td>1-12 Devre<\/td>\n<\/tr>\n<tr>\n<td>PA-4*<\/td>\n<td>Ak\u0131m trafosu oran\u0131 \u00f6n ayar\u0131<\/td>\n<td>Mevcut yap\u0131land\u0131rma<\/td>\n<td>50~4000<\/td>\n<\/tr>\n<tr>\n<td>C-01<\/td>\n<td>1. devre kondansat\u00f6r \u00f6n ayar\u0131<\/td>\n<td>Mevcut yap\u0131land\u0131rma<\/td>\n<td>0~150 kVAr<\/td>\n<\/tr>\n<tr>\n<td>C-12<\/td>\n<td>12. devre kondansat\u00f6r \u00f6n ayar\u0131<\/td>\n<td>Mevcut yap\u0131land\u0131rma<\/td>\n<td>0~150 kVAr<\/td>\n<\/tr>\n<tr>\n<td>PA-5<\/td>\n<td>Kesme \u00f6n ayar\u0131<\/td>\n<td>1.00<\/td>\n<td>0.70~0.70<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Not: * Reaktif g\u00fc\u00e7 kontrol modunda<\/p>\n<p><strong>Temel \u00d6zellikler<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"158\">Model \u00f6zellikleri<\/td>\n<td width=\"146\">Boyut<\/td>\n<td width=\"155\">Nominal gerilim (V AC; modele g\u00f6re do\u011frulanmal\u0131d\u0131r)<\/td>\n<td width=\"155\">Sinyal frekans\u0131<\/td>\n<\/tr>\n<tr>\n<td>JKW5C<\/td>\n<td>113x113 mm<\/td>\n<td>AC220V1380V<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>JKW5B<\/td>\n<td>162x102mm<\/td>\n<td>AC380V<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>JKG2B<\/td>\n<td>162x102mm<\/td>\n<td>AC22OV<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>JKW1B<\/td>\n<td>140x102mm<\/td>\n<td>AC220V1380V<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>JKW58<\/td>\n<td>140x140mm<\/td>\n<td>AC220V1380V<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>JKWD5<\/td>\n<td>113x113 mm<\/td>\n<td>AC220V\/380V<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>JKWF-12<\/td>\n<td>113x113 mm<\/td>\n<td>AC220V<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>JKWF-16<\/td>\n<td>113x113 mm<\/td>\n<td>AC22OV<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>JKWF-16<\/td>\n<td>140x140mm<\/td>\n<td>AC22OV<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>RPCF-16<\/td>\n<td>113x113 mm<\/td>\n<td>AC380V<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td width=\"116\">D\u00f6ng\u00fc<\/td>\n<td width=\"213\">\u00c7\u0131kt\u0131<\/td>\n<td width=\"323\">Tazminat y\u00f6ntemi<\/td>\n<\/tr>\n<tr>\n<td>1-12 d\u00f6ng\u00fc<\/td>\n<td>Statik durum<\/td>\n<td>Ortak kompanzasyon<\/td>\n<\/tr>\n<tr>\n<td>1-12 d\u00f6ng\u00fc<\/td>\n<td>Statik durum<\/td>\n<td>Ortak kompanzasyon<\/td>\n<\/tr>\n<tr>\n<td>1-12 d\u00f6ng\u00fc<\/td>\n<td>Statik durum<\/td>\n<td>Ortak kompanzasyon<\/td>\n<\/tr>\n<tr>\n<td>1-12 d\u00f6ng\u00fc<\/td>\n<td>Statik durum<\/td>\n<td>Ortak kompanzasyon<\/td>\n<\/tr>\n<tr>\n<td>1-12 d\u00f6ng\u00fc<\/td>\n<td>Statik durum<\/td>\n<td>Ortak kompanzasyon<\/td>\n<\/tr>\n<tr>\n<td>1-12 d\u00f6ng\u00fc<\/td>\n<td>DC12V<\/td>\n<td>Ortak kompanzasyon<\/td>\n<\/tr>\n<tr>\n<td>1-12 d\u00f6ng\u00fc<\/td>\n<td>Statik durum\/DC12V<\/td>\n<td>Ortak kompanzasyon + alt kompanzasyon<\/td>\n<\/tr>\n<tr>\n<td>1-16 d\u00f6ng\u00fc<\/td>\n<td>DC12V<\/td>\n<td>Ortak kompanzasyon + alt kompanzasyon<\/td>\n<\/tr>\n<tr>\n<td>1-16 d\u00f6ng\u00fc<\/td>\n<td>Statik durum<\/td>\n<td>Ortak kompanzasyon + alt kompanzasyon<\/td>\n<\/tr>\n<tr>\n<td>1-16 d\u00f6ng\u00fc<\/td>\n<td>Statik durum\/DC12V<\/td>\n<td>Ortak kompanzasyon<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Kablo Ba\u011flant\u0131 Y\u00f6ntemi<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1037\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/10.JKW_-scaled.webp\" alt=\"\" width=\"772\" height=\"2560\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>JKW serisi otomatik reaktif g\u00fc\u00e7 kompanzasyon kontrol\u00f6r\u00fc, AC \u00f6rnekleme teknolojisini kullanarak temel g\u00fc\u00e7 fakt\u00f6r\u00fcn\u00fc ve temel reaktif g\u00fcc\u00fc kontrol fiziksel b\u00fcy\u00fckl\u00fckleri olarak esas al\u0131r. B\u00f6ylece y\u00fcksek kontrol hassasiyeti sa\u011flar, anahtarlama sal\u0131n\u0131mlar\u0131n\u0131 \u00f6nler ve harmoniklerden etkilenmez. T\u00fcm kontrol parametreleri dijital olarak ayarlan\u0131r; bu sayede kullan\u0131m kolayla\u015f\u0131r ve elektrik kesintilerinde veri kayb\u0131 \u00f6nlenir. Bu kontrol\u00f6r, anahtarlama s\u0131kl\u0131\u011f\u0131n\u0131 azaltmak, sistemin kullan\u0131m \u00f6mr\u00fcn\u00fc uzatmak ve g\u00fc\u00e7l\u00fc parazit \u00f6nleme kapasitesi sa\u011flamak i\u00e7in otomatik optimizasyon kontrol\u00fc kullan\u0131r. Ayr\u0131ca, sistemin kilitlenmesine veya veri kayb\u0131na neden olmadan 2000 V parazit darbelerine dayanabilir ve istikrarl\u0131, g\u00fcvenilir \u00e7al\u0131\u015fma sa\u011flar.<\/p>","protected":false},"featured_media":1622,"template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[37,35],"product_tag":[],"class_list":["post-1296","product","type-product","status-publish","has-post-thumbnail","product_cat-intelligent-controller","product_cat-reactive-power-compensator","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product\/1296","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/media\/1622"}],"wp:attachment":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/media?parent=1296"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product_brand?post=1296"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product_cat?post=1296"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product_tag?post=1296"}],"curies":[{"name":"Naber","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}