{"id":1298,"date":"2026-04-29T10:02:18","date_gmt":"2026-04-29T02:02:18","guid":{"rendered":"https:\/\/w6pown520g.wpdns.site\/?post_type=product&#038;p=1298"},"modified":"2026-06-29T15:47:13","modified_gmt":"2026-06-29T07:47:13","slug":"bsmj-cylinder-series-cylindrical-capacitors","status":"publish","type":"product","link":"https:\/\/cnbygele.com\/tr\/product\/bsmj-cylinder-series-cylindrical-capacitors\/","title":{"rendered":"BSMJ (Silindir) Serisi Silindirik Kondansat\u00f6rler"},"content":{"rendered":"<h2><strong><b>\u00dcr\u00fcn A\u00e7\u0131klamas\u0131<\/b><\/strong><\/h2>\n<p>BSMJ(silindir) serisi silindirik kondansat\u00f6rler; g\u00fc\u00e7 fakt\u00f6r\u00fcn\u00fc iyile\u015ftirmek, reaktif g\u00fc\u00e7 kay\u0131plar\u0131n\u0131 azaltmak ve gerilim kalitesini art\u0131rmak amac\u0131yla, 1000V ve alt\u0131ndaki anma gerilimine sahip g\u00fc\u00e7 frekansl\u0131 AC g\u00fc\u00e7 sistemleri i\u00e7in uygundur.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1058\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/5.BSMJ_-1.webp\" alt=\"\" width=\"1560\" height=\"646\" \/><\/p>\n<h2>Ana Teknik Parametreler<\/h2>\n<table style=\"height: 493px;\" width=\"1161\">\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"188\">Proje<\/td>\n<td width=\"620\">Parametre<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"188\">Kay\u0131p a\u00e7\u0131s\u0131 tanjant de\u011feri<\/td>\n<td width=\"620\">Anma \u015febeke frekans\u0131 geriliminde 0,0012'nin alt\u0131nda<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"188\">Kapasite<br \/>\nsapma<\/td>\n<td width=\"620\">Kondansat\u00f6r\u00fcn \u00f6l\u00e7\u00fclen de\u011feri ile anma de\u011feri aras\u0131ndaki fark<br \/>\nO~+10% de\u011ferini a\u015fmayacak ve maksimum kapasitans ile minimum kapasitans aras\u0131ndaki oran<br \/>\n\u00fc\u00e7 fazl\u0131 bir kondansat\u00f6rde herhangi iki hat terminali aras\u0131nda \u00f6l\u00e7\u00fclen<br \/>\n1,08'i ge\u00e7meyecek<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" width=\"67\">Dayanmak<br \/>\ngerilim<\/td>\n<td width=\"121\">Kutuplar aras\u0131<\/td>\n<td width=\"620\">G\u00fc\u00e7 frekans\u0131 2.15Un, 2S<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"121\">Polar kabuk<\/td>\n<td width=\"620\">600V ve alt\u0131 anma gerilimi, 3.6kV uygulanan gerilim, 5S<\/td>\n<\/tr>\n<tr>\n<td width=\"620\">600V ve alt\u0131 anma gerilimi, 7.2kV uygulanan gerilim, 5S<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"188\">\u0130zin verilen maksimum a\u015f\u0131r\u0131 gerilim<\/td>\n<td width=\"620\">1.1 Her 24 saatte 8 saati ge\u00e7memek kayd\u0131yla<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"188\">\u0130zin verilen maksimum a\u015f\u0131r\u0131 ak\u0131m<\/td>\n<td width=\"620\">1,3 \u0130n\u00e7<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"188\">De\u015farj (kendi kendine de\u015farj)<br \/>\nkarakteristikler<\/td>\n<td width=\"620\">Kondansat\u00f6r, \u015funu azaltabilen bir de\u015farj cihaz\u0131 ile donat\u0131lm\u0131\u015ft\u0131r:<br \/>\nKondansat\u00f6r\u00fcn kalan voltaj\u0131n\u0131n 3 dakika i\u00e7inde 2Un'den 75V veya alt\u0131na d\u00fc\u015fmesi<br \/>\ng\u00fc\u00e7 kayna\u011f\u0131n\u0131n ba\u011flant\u0131s\u0131n\u0131 kesmenin<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"188\">Y\u00f6netici standartlar\u0131<\/td>\n<td width=\"620\">IEC60831-2017,GB\/T12747-2014<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Ana \u00d6zellikler Ve D\u0131\u015f Boyutlar<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1060\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/7.BSMJ_-1.webp\" alt=\"\" width=\"1920\" height=\"796\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td rowspan=\"2\" width=\"112\">Teknik \u00d6zellikler<\/td>\n<td rowspan=\"2\" width=\"96\">Kapasite (\u03bcF)<\/td>\n<td rowspan=\"2\" width=\"81\">Ak\u0131m (a)<\/td>\n<td colspan=\"2\" width=\"100\">V\u00fccut boyutu (mm)<\/td>\n<td rowspan=\"2\" width=\"175\">Taban montaj\u0131 (mm)<\/td>\n<\/tr>\n<tr>\n<td>A<\/td>\n<td>B<\/td>\n<\/tr>\n<tr>\n<td>0.45-10-3<\/td>\n<td>157.3<\/td>\n<td>12.8<\/td>\n<td>16<\/td>\n<td>245<\/td>\n<td>M12x17<\/td>\n<\/tr>\n<tr>\n<td>0.45-15-3<\/td>\n<td>235.9<\/td>\n<td>19.2<\/td>\n<td>96<\/td>\n<td>245<\/td>\n<td>M16x25<\/td>\n<\/tr>\n<tr>\n<td>0.45-20-3<\/td>\n<td>314.5<\/td>\n<td>25.7<\/td>\n<td>106<\/td>\n<td>245<\/td>\n<td>M16x25<\/td>\n<\/tr>\n<tr>\n<td>0.45-25-3<\/td>\n<td>393.2<\/td>\n<td>32.1<\/td>\n<td>116<\/td>\n<td>245<\/td>\n<td>M16x25<\/td>\n<\/tr>\n<tr>\n<td>0.45-30-3<\/td>\n<td>471.8<\/td>\n<td>38.5<\/td>\n<td>116<\/td>\n<td>290<\/td>\n<td>M16x25<\/td>\n<\/tr>\n<tr>\n<td>0.45-40-3<\/td>\n<td>629.1<\/td>\n<td>51.3<\/td>\n<td>126<\/td>\n<td>290<\/td>\n<td>M16x25<\/td>\n<\/tr>\n<tr>\n<td>0.48-10-3<\/td>\n<td>138.2<\/td>\n<td>12.0<\/td>\n<td>16<\/td>\n<td>245<\/td>\n<td>M12x17<\/td>\n<\/tr>\n<tr>\n<td>0.48-15-3<\/td>\n<td>207.3<\/td>\n<td>18.0<\/td>\n<td>96<\/td>\n<td>245<\/td>\n<td>M16x25<\/td>\n<\/tr>\n<tr>\n<td>0.48-20-3<\/td>\n<td>276.5<\/td>\n<td>24.1<\/td>\n<td>106<\/td>\n<td>245<\/td>\n<td>M16x25<\/td>\n<\/tr>\n<tr>\n<td>0.48-25-3<\/td>\n<td>345.6<\/td>\n<td>30.1<\/td>\n<td>116<\/td>\n<td>245<\/td>\n<td>M16x25<\/td>\n<\/tr>\n<tr>\n<td>0.48-30-3<\/td>\n<td>414.7<\/td>\n<td>36.1<\/td>\n<td>116<\/td>\n<td>290<\/td>\n<td>M16x25<\/td>\n<\/tr>\n<tr>\n<td>0.48-40-3<\/td>\n<td>552.9<\/td>\n<td>48.1<\/td>\n<td>126<\/td>\n<td>290<\/td>\n<td>M16 x25<\/td>\n<\/tr>\n<tr>\n<td>0.525-10-3<\/td>\n<td>115.5<\/td>\n<td>11.0<\/td>\n<td>R<\/td>\n<td>245<\/td>\n<td>M12x17<\/td>\n<\/tr>\n<tr>\n<td>0.525-15-3<\/td>\n<td>173.3<\/td>\n<td>16.5<\/td>\n<td>96<\/td>\n<td>245<\/td>\n<td>M16x25<\/td>\n<\/tr>\n<tr>\n<td>0.525-20-3<\/td>\n<td>231.1<\/td>\n<td>22.0<\/td>\n<td>106<\/td>\n<td>245<\/td>\n<td>M16x25<\/td>\n<\/tr>\n<tr>\n<td>0.525-25-3<\/td>\n<td>288.9<\/td>\n<td>27.5<\/td>\n<td>116<\/td>\n<td>245<\/td>\n<td>M16x25<\/td>\n<\/tr>\n<tr>\n<td>0.525-30-3<\/td>\n<td>346.6<\/td>\n<td>33.0<\/td>\n<td>116<\/td>\n<td>290<\/td>\n<td>M16x25<\/td>\n<\/tr>\n<tr>\n<td>0.525-40-3<\/td>\n<td>462.2<\/td>\n<td>44.0<\/td>\n<td>126<\/td>\n<td>290<\/td>\n<td>M16x25<\/td>\n<\/tr>\n<tr>\n<td>0.525-50-3<\/td>\n<td>577.7<\/td>\n<td>55.0<\/td>\n<td>136<\/td>\n<td>290<\/td>\n<td>M16x25<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Not: Monofaze \u00fcr\u00fcnlerin harici montaj boyutlar\u0131, ayn\u0131 spesifikasyondaki trifaze \u00fcr\u00fcnlerinki ile ayn\u0131d\u0131r.<\/p>\n<p>\u015eirketimiz, kullan\u0131c\u0131lar i\u00e7in \u00fcr\u00fcnlerin di\u011fer \u00f6zelliklerini de \u00f6zelle\u015ftirebilir. \u00d6zel gereksinimleriniz varsa, l\u00fctfen m\u00fczakere edin ve sipari\u015f verin.<\/p>\n<h2>Talimatlar<\/h2>\n<p><strong>Kullanma Talimat\u0131<\/strong><\/p>\n<ul>\n<li>Orijinal fabrika ambalaj\u0131nda ta\u015f\u0131y\u0131n; dikkatli tutun.<\/li>\n<li>Kuru, a\u015f\u0131nd\u0131r\u0131c\u0131 olmayan gaz i\u00e7eren kapal\u0131 bir ortamda saklay\u0131n.<\/li>\n<\/ul>\n<p><strong>Kullan\u0131c\u0131 kabul muayenesi<\/strong><\/p>\n<ul>\n<li>Kullanmadan \u00f6nce isim levhas\u0131 modelinin sat\u0131n al\u0131nan \u00fcr\u00fcnle e\u015fle\u015fti\u011fini kontrol edin.<\/li>\n<li>Kapasite testi: 4.2\u2019ye g\u00f6re, 2% ba\u011f\u0131l hataya sahip cihazlar kullan\u0131larak ger\u00e7ekle\u015ftirilmelidir.<\/li>\n<li>Dayan\u0131m gerilimi testi: 4.3 numaral\u0131 maddede belirtilen gerilimin 75%\u2019sini uygulay\u0131n.<\/li>\n<\/ul>\n<p><strong>Kurulum ve \u00e7al\u0131\u015ft\u0131rma<\/strong><\/p>\n<ul>\n<li>\u0130\u00e7 mekana kurun, 2000 metrenin alt\u0131ndaki rak\u0131mlarda kullan\u0131m i\u00e7indir.<\/li>\n<li>Ortam s\u0131cakl\u0131\u011f\u0131 -25~+50 \u00b0C, nem &lt;85%; talep \u00fczerine d\u00fc\u015f\u00fck s\u0131cakl\u0131k versiyonu (-40~+50 \u00b0C) temin edilebilir.<\/li>\n<\/ul>\n<ul>\n<li>Kurulum yeri: do\u011frudan g\u00fcne\u015f \u0131\u015f\u0131\u011f\u0131ndan, ya\u011fmurdan, a\u015f\u0131r\u0131 tozdan ve \u015fiddetli titre\u015fimden ka\u00e7\u0131n\u0131n; bo\u015fluk &gt;30 mm; yaz aylar\u0131ndaki y\u00fcksek s\u0131cakl\u0131klarda iyi havaland\u0131rma ve \u0131s\u0131 da\u011f\u0131l\u0131m\u0131 sa\u011flay\u0131n.<\/li>\n<li>Montajdan \u00f6nce, a\u015f\u0131r\u0131 gerilim alt\u0131nda uzun s\u00fcreli \u00e7al\u0131\u015fmay\u0131 \u00f6nlemek i\u00e7in kondansat\u00f6r giri\u015finden sonraki gerilim y\u00fckselmesini dikkate al\u0131n; gerilim dalga bi\u00e7imini ve \u015febeke \u00f6zelliklerini kontrol edin; harmonik kaynaklar\u0131 mevcutsa harmonikleri s\u0131n\u0131rlamak i\u00e7in \u00f6nlemler al\u0131n.<\/li>\n<li>\u0130nd\u00fcksiyon motoruyla paralel ba\u011fland\u0131\u011f\u0131nda, kondansat\u00f6r ak\u0131m\u0131 motorun bo\u015fta ak\u0131m\u0131n\u0131n &lt;90%\u2019sinden az olmal\u0131d\u0131r. Hat ve topraklama terminalleri i\u00e7in esnek bak\u0131r teller kullan\u0131n ve iyi temas sa\u011flad\u0131\u011f\u0131ndan emin olun; hasar\u0131 \u00f6nlemek i\u00e7in terminalleri d\u00fczenli olarak kontrol edin.<\/li>\n<li>A\u015f\u0131r\u0131 voltaj hasar\u0131n\u0131 \u00f6nlemek i\u00e7in ba\u011flant\u0131 kesilmesi ve yeniden ba\u011flanma aras\u0131ndaki s\u00fcre &gt;3 dk (kendi kendine de\u015farj s\u00fcresi) olmal\u0131d\u0131r.<\/li>\n<\/ul>\n<p><strong>Sipari\u015f talimatlar\u0131<\/strong><\/p>\n<ul>\n<li>Kullan\u0131c\u0131lar \u00fcr\u00fcn\u00fcn anma gerilimini, anma s\u0131\u011fas\u0131n\u0131, faz say\u0131s\u0131n\u0131 ve di\u011fer parametreleri sa\u011flamal\u0131d\u0131r.<\/li>\n<li>Kullan\u0131c\u0131lar kullan\u0131m yerinin baz\u0131 \u00f6zelliklerini sa\u011flamak i\u00e7in ellerinden gelenin en iyisini yapmal\u0131d\u0131r.<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>BSMJ (Silindir) Serisi Silindirik Kondansat\u00f6rler, kolay montaj ve minimum alan gereksinimi i\u00e7in yuvarlak tasar\u0131ma sahip y\u00fcksek kaliteli anodize al\u00fcminyum g\u00f6vdelere sahiptir. Benzersiz tasar\u0131mlar\u0131, y\u00fcksek ortama s\u0131cakl\u0131klar\u0131na ve \u00f6nemli sistem gerilimi dalgalanmalar\u0131na dayanmalar\u0131na olanak tan\u0131r. Dahili olarak bir de\u015farj direnci ve g\u00fcvenlik cihaz\u0131 ile donat\u0131lm\u0131\u015f olup, g\u00fcvenlik cihaz\u0131, artan i\u00e7 bas\u0131n\u00e7 veya kondansat\u00f6r ar\u0131zas\u0131 durumunda b\u00fcy\u00fcmenin \u00f6nlenmesi i\u00e7in g\u00fcc\u00fc otomatik olarak keser.<\/p>","protected":false},"featured_media":1354,"template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[38,35],"product_tag":[],"class_list":["post-1298","product","type-product","status-publish","has-post-thumbnail","product_cat-power-film-capacitor","product_cat-reactive-power-compensator","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product\/1298","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/media\/1354"}],"wp:attachment":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/media?parent=1298"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product_brand?post=1298"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product_cat?post=1298"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product_tag?post=1298"}],"curies":[{"name":"Naber","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}