{"id":1301,"date":"2026-04-29T10:02:18","date_gmt":"2026-04-29T02:02:18","guid":{"rendered":"https:\/\/w6pown520g.wpdns.site\/?post_type=product&#038;p=1301"},"modified":"2026-06-29T15:58:59","modified_gmt":"2026-06-29T07:58:59","slug":"byfk-series-intelligent-low-voltage-composite-switch","status":"publish","type":"product","link":"https:\/\/cnbygele.com\/tr\/product\/byfk-series-intelligent-low-voltage-composite-switch\/","title":{"rendered":"BYFK Serisi Ak\u0131ll\u0131 Al\u00e7ak Gerilim Kompozit \u015ealteri"},"content":{"rendered":"<h2><strong><b>Ana Teknik \u00d6zellikler <\/b><\/strong><\/h2>\n<p><strong>Koruma Fonksiyonu<\/strong><\/p>\n<ul>\n<li>Bir mikroi\u015flemci kullanarak r\u00f6lelerin, giri\u015f g\u00fcc\u00fcn\u00fcn ve y\u00fcklerin \u00e7al\u0131\u015fma durumunu ger\u00e7ek zamanl\u0131 olarak izler, kapsaml\u0131 koruma fonksiyonlar\u0131na sahiptir.<\/li>\n<li>Voltaj hatas\u0131 faz kayb\u0131 korumas\u0131: Sistem voltaj\u0131 faz kayb\u0131 beslemesindeyken \u015falter kapanmay\u0131 reddeder. Ba\u011flant\u0131 sonras\u0131 faz kayb\u0131 meydana gelirse otomatik olarak ba\u011flant\u0131y\u0131 keser.<\/li>\n<li>G\u00fc\u00e7 kayna\u011f\u0131 voltaj\u0131 faz kayb\u0131 korumas\u0131: \u00c7al\u0131\u015fma g\u00fc\u00e7 kayna\u011f\u0131nda faz kayb\u0131 oldu\u011funda anahtar kapanmay\u0131 reddeder. Ba\u011fland\u0131ktan sonra faz kayb\u0131 meydana gelirse otomatik olarak devre d\u0131\u015f\u0131 kal\u0131r.<\/li>\n<li>Kendi kendine ar\u0131za te\u015fhis korumas\u0131: Sistem, r\u00f6lenin \u00e7al\u0131\u015fma durumunu otomatik olarak izler. Bir ar\u0131za meydana gelirse, kapanmay\u0131 reddeder veya otomatik olarak ba\u011flant\u0131y\u0131 keser<\/li>\n<li>Y\u00fcks\u00fcz koruma: Y\u00fck ba\u011fl\u0131 de\u011filken anahtar kapanmay\u0131 reddeder. Elektrik kesintisi korumas\u0131: Ba\u011fland\u0131ktan sonra ani bir elektrik kesintisi olursa, otomatik olarak ba\u011flant\u0131y\u0131 keser.<\/li>\n<\/ul>\n<p><strong>D\u00fc\u015f\u00fck G\u00fc\u00e7 T\u00fcketimi<\/strong><\/p>\n<p>R\u00f6le, yaln\u0131zca anahtarlama an\u0131nda elektrik t\u00fcketir ve normal zamanlarda elektrik t\u00fcketmez; b\u00f6ylece enerji tasarrufu ve t\u00fcketim azl\u0131\u011f\u0131 sa\u011flan\u0131r.<\/p>\n<p><strong>\u0130\u015f G\u00fcvencesi<\/strong><\/p>\n<p>T\u00fcm kontrol giri\u015f sinyalleri ve dahili devreler g\u00fcvenli bir \u015fekilde yal\u0131t\u0131lm\u0131\u015f olup, geli\u015fmi\u015f ak\u0131ll\u0131 kontrol teknolojisi ve patentli cihazlar benimsenmi\u015ftir. Benzer \u00fcr\u00fcnlerle kar\u015f\u0131la\u015ft\u0131r\u0131ld\u0131\u011f\u0131nda, a\u015f\u0131r\u0131 ak\u0131m ve g\u00fcvenlik g\u00fcvenilirli\u011fi konular\u0131nda son derece y\u00fcksek performans avantajlar\u0131na sahiptir.<\/p>\n<h2><strong><b>S\u0131n\u0131fland\u0131rma <\/b><\/strong><\/h2>\n<ul>\n<li>\u00dc\u00e7 fazl\u0131 ortak kompanzasyon tipi: Kompanzasyon kondansat\u00f6r\u00fcn\u00fcn kablolama y\u00f6ntemi \u00fc\u00e7gen ba\u011flant\u0131d\u0131r (\u25b3 ile g\u00f6sterilir)<\/li>\n<li>\u00dc\u00e7 fazl\u0131 kompanzasyon tipi: Kompanzasyon kondansat\u00f6r\u00fcn\u00fcn kablolama y\u00f6ntemi y\u0131ld\u0131z ba\u011flant\u0131d\u0131r (Y ile temsil edilir)<\/li>\n<\/ul>\n<h2><strong><b>Avantaj<\/b><\/strong><\/h2>\n<p>Harici kontrol sinyalleri al\u0131nd\u0131ktan sonra, ak\u0131ll\u0131 de\u011ferlendirme yoluyla, s\u0131f\u0131r ge\u00e7i\u015fli anahtarlama, d\u00fc\u015f\u00fck kalk\u0131\u015f ak\u0131m\u0131, kontaklar\u0131n yap\u0131\u015fmamas\u0131 ve d\u00fc\u015f\u00fck enerji t\u00fcketimi sa\u011flamak i\u00e7in en uygun anahtarlama noktas\u0131 otomatik olarak bulunur; ayr\u0131ca voltaj anormallik korumas\u0131, faz kayb\u0131 korumas\u0131, bile\u015fen ar\u0131za korumas\u0131 ve \u00e7al\u0131\u015fma g\u00f6stergesi gibi fonksiyonlara sahiptir. Benzer \u00fcr\u00fcnlerle kar\u015f\u0131la\u015ft\u0131r\u0131ld\u0131\u011f\u0131nda, BYFK serisi ak\u0131ll\u0131 al\u00e7ak gerilim kompozit anahtarlar\u0131, kalk\u0131\u015f ak\u0131mlar\u0131n\u0131 ve g\u00fcvenlik g\u00fcvenilirliklerini b\u00fcy\u00fck \u00f6l\u00e7\u00fcde art\u0131r\u0131r.<\/p>\n<h2><strong><b>\u015eartname<\/b><\/strong><\/h2>\n<table style=\"height: 819px;\" width=\"1219\">\n<tbody>\n<tr>\n<td width=\"305\">Proje<\/td>\n<td width=\"361\">Parametre<\/td>\n<\/tr>\n<tr>\n<td>Ortam s\u0131cakl\u0131\u011f\u0131<\/td>\n<td>-20\u2103~+55\u2103<\/td>\n<\/tr>\n<tr>\n<td>Ba\u011f\u0131l nem<\/td>\n<td>40 \u2103&#x27;de, 20%~90%<\/td>\n<\/tr>\n<tr>\n<td>Anma gerilimi<\/td>\n<td width=\"361\">380V\/220V \u00fc\u00e7 fazl\u0131 d\u00f6rt telli AC 50Hz \u00dc\u00e7 fazl\u0131 voltaj\u0131n e\u015f zamanl\u0131 de\u011fi\u015fimi<\/td>\n<\/tr>\n<tr>\n<td>\u0130zin verilen sapma<\/td>\n<td>\u00b1 20%\u2019yi a\u015fmamal\u0131d\u0131r<\/td>\n<\/tr>\n<tr>\n<td>Gerilim bozulma oran\u0131<\/td>\n<td>&lt;5%<\/td>\n<\/tr>\n<tr>\n<td>Anma frekans\u0131<\/td>\n<td>50 Hz<\/td>\n<\/tr>\n<tr>\n<td>Anma ak\u0131m\u0131<\/td>\n<td>&lt;80A (Normal tip); &lt;80A (Devre kesicili tip)<\/td>\n<\/tr>\n<tr>\n<td>Hizmet \u00f6mr\u00fc<\/td>\n<td>500.000 kez<\/td>\n<\/tr>\n<tr>\n<td>Faz numaras\u0131<\/td>\n<td width=\"361\">\u00dc\u00e7gen ba\u011flant\u0131 y\u00f6ntemi (\u00fc\u00e7 fazl\u0131); Y \u015feklinde ba\u011flant\u0131 y\u00f6ntemi (tek fazl\u0131)<\/td>\n<\/tr>\n<tr>\n<td>\u00dc\u00e7 fazl\u0131 kontrol kapasitesi<\/td>\n<td>&lt;40Kvar<\/td>\n<\/tr>\n<tr>\n<td>Tek fazl\u0131 kontrol kapasitesi<\/td>\n<td>&lt;10Kvar<\/td>\n<\/tr>\n<tr>\n<td>g\u00fc\u00e7 kayb\u0131<\/td>\n<td>&lt;1.5VA<\/td>\n<\/tr>\n<tr>\n<td>Temas bas\u0131nc\u0131 d\u00fc\u015f\u00fc\u015f\u00fc<\/td>\n<td>&lt;100mV<\/td>\n<\/tr>\n<tr>\n<td>Kontak dayan\u0131m gerilimi<\/td>\n<td>&gt;1600V<\/td>\n<\/tr>\n<tr>\n<td>Yan\u0131t s\u00fcresi<\/td>\n<td>&lt;1000ms<\/td>\n<\/tr>\n<tr>\n<td>Her a\u00e7\u0131l\u0131p kapanma aras\u0131ndaki s\u00fcre<\/td>\n<td>&gt;5 Saniye<\/td>\n<\/tr>\n<tr>\n<td>\u0130ki ard\u0131\u015f\u0131k ba\u011flant\u0131 aras\u0131ndaki s\u00fcre<\/td>\n<td>=35 Saniye<\/td>\n<\/tr>\n<tr>\n<td>Kontrol sinyali<\/td>\n<td>DC12V\u00b120%; De\u011fi\u015fim\/\u0130leti\u015fim (\u0130ste\u011fe ba\u011fl\u0131)<\/td>\n<\/tr>\n<tr>\n<td>Giri\u015f empedans\u0131<\/td>\n<td>&gt;6,8B<\/td>\n<\/tr>\n<tr>\n<td>\u0130letim empedans\u0131<\/td>\n<td>&lt;0,0032<\/td>\n<\/tr>\n<tr>\n<td>Kalk\u0131\u015f ak\u0131m\u0131<\/td>\n<td>Anma ak\u0131m\u0131n\u0131n 1,5 kat\u0131ndan az<\/td>\n<\/tr>\n<tr>\n<td>Geri bildirim konta\u011f\u0131n\u0131n anma ak\u0131m\u0131<\/td>\n<td>1A (ba\u011fl\u0131 olarak tak)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong><b>G\u00f6r\u00fcn\u00fcm ve Kurulum Boyutlar\u0131<\/b><\/strong><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1641\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/BYFK.webp\" alt=\"\" width=\"1920\" height=\"959\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/BYFK.webp 1920w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/BYFK-300x150.webp 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/BYFK-1024x511.webp 1024w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/BYFK-768x384.webp 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/BYFK-1536x767.webp 1536w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/BYFK-600x300.webp 600w\" sizes=\"auto, (max-width: 1920px) 100vw, 1920px\" \/><\/p>\n<h2><strong><b>Kablo Ba\u011flant\u0131 Y\u00f6ntemi<\/b><\/strong><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1088\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/7.BYFK_.webp\" alt=\"\" width=\"1920\" height=\"1215\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>BYFK kompozit \u015falter; gerilim s\u0131f\u0131r ge\u00e7i\u015fli iletim ve ak\u0131m s\u0131f\u0131r ge\u00e7i\u015fli kesme sa\u011flamak \u00fczere ak\u0131ll\u0131 \u00e7ipler, say\u0131sal devreler ve manyetik tutma r\u00f6lelerinin bir kombinasyonu olup, \u015falterin a\u00e7ma ve kapama an\u0131nda a\u015f\u0131r\u0131 gerilim \u00fcremeden tamamen s\u0131f\u0131r ge\u00e7i\u015fte anahtarlama yapmas\u0131na olanak tan\u0131r. \u015ealterler, a\u015f\u0131r\u0131 ak\u0131m olmamas\u0131, son derece d\u00fc\u015f\u00fck g\u00fc\u00e7 t\u00fcketimi, y\u00fcksek \u00f6m\u00fcr ve d\u00fc\u015f\u00fck ar\u0131za oran\u0131 gibi bir\u00e7ok avantaja sahip olup, al\u00e7ak gerilim reaktif g\u00fc\u00e7 kompenzasyonu alan\u0131nda yayg\u0131n olarak kullan\u0131lmaktad\u0131r.<\/p>","protected":false},"featured_media":1638,"template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[35,41],"product_tag":[],"class_list":["post-1301","product","type-product","status-publish","has-post-thumbnail","product_cat-reactive-power-compensator","product_cat-switch","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product\/1301","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/media\/1638"}],"wp:attachment":[{"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/media?parent=1301"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product_brand?post=1301"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product_cat?post=1301"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnbygele.com\/tr\/wp-json\/wp\/v2\/product_tag?post=1301"}],"curies":[{"name":"Naber","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}