{"id":2323,"date":"2026-08-06T15:00:00","date_gmt":"2026-08-06T07:00:00","guid":{"rendered":"https:\/\/cnbygele.com\/blog\/cement-kiln-vfd-harmonics-operating-log\/"},"modified":"2026-08-24T17:24:32","modified_gmt":"2026-08-24T09:24:32","slug":"cement-kiln-vfd-harmonics-operating-log","status":"publish","type":"post","link":"https:\/\/cnbygele.com\/vi\/blog\/cement-kiln-vfd-harmonics-operating-log\/","title":{"rendered":"Cement Kiln VFD Harmonics: Operating-State Log Guide"},"content":{"rendered":"<div class=\"b2b-article\">\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Cement plants combine kiln rotation drives, large ID fans, raw mills, and finish-grinding VFDs on shared buses where harmonic current shifts with production rate and fuel changes.<\/strong> Assessing cement kiln VFD harmonics requires an operating-state log that ties each spectrum capture to kiln speed, fan damper position, and mill loading rather than a single afternoon snapshot.<\/p>\n<nav class=\"b2b-toc\" style=\"background:#f5f8fa;padding:16px 20px;border-radius:8px;margin:0 0 24px\">\n<h2 id=\"contents\" style=\"margin:42px 0 14px;scroll-margin-top:96px\">M\u1ee5c l\u1ee5c<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"#set-the-measurement-boundary-for-kiln-and-fan-feeders\">Set the measurement boundary for kiln and fan feeders<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#keep-distortion-review-separate-from-process-and-emission-questions\">Keep distortion review separate from process and emission questions<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#choose-mitigation-paths-after-the-operating-log-is-complete\">Choose mitigation paths after the operating log is complete<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#document-installation-and-acceptance-before-equipment-arrives\">Document installation and acceptance before equipment arrives<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#product-inquiry-checklist-for-cement-plants\">Product inquiry checklist for cement plants<\/a><\/li>\n<\/ul>\n<\/nav>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"direct-answer\">Tr\u1ea3 l\u1eddi tr\u1ef1c ti\u1ebfp<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Cement plants combine kiln rotation drives, large ID fans, raw mills, and finish-grinding VFDs on shared buses where harmonic current shifts with production rate and fuel changes. Assessing cement kiln VFD harmonics requires an operating-state log that ties each spectrum capture to kiln speed, fan damper position, and mill loading rather than a single afternoon snapshot.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Power-quality discussions in cement plants often mix kiln-process concerns with feeder-level distortion readings. CNBYG can review AHF\/APF product-line fit when measured harmonic current is the stated objective. This article does not confirm kiln process stability, clinker quality, emission compliance, or a guaranteed harmonic result. Browse related topics in the <a href=\"https:\/\/cnbygele.com\/vi\/power-quality-system-guides\/\">H\u01b0\u1edbng d\u1eabn K\u1ef9 thu\u1eadt H\u1ec7 th\u1ed1ng Ch\u1ea5t l\u01b0\u1ee3ng \u0110i\u1ec7n<\/a>.<\/p>\n<figure class=\"wp-block-image size-large\" style=\"clear:both;display:block;margin:28px 0;float:none;width:100%;\"><img decoding=\"async\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/07\/reactive-power-and-harmonic-compensation-devices-overview-product-1.webp\" alt=\"Cement kiln VFD harmonics operating-state logging at plant feeders\" class=\"alignnone size-large\" style=\"display:block;max-width:640px;height:auto;float:none;margin:0 auto;\" \/><\/figure>\n<p style=\"clear:both;margin:0;padding:0;height:0;line-height:0;\">&nbsp;<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"set-the-measurement-boundary-for-kiln-and-fan-feeders\">Set the measurement boundary for kiln and fan feeders<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Start by naming the bus where the mitigation decision will apply. A logger on a kiln main-drive feeder characterizes that drive group. A logger at the medium-voltage incomer or PCC answers a plant-boundary question. Document CT ratios, polarity, aggregation interval, voltage reference, and which major loads were online during each capture.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">For kiln main drives, induced-draft fans, and raw-mill VFD groups in cement plants, build a time-stamped operating log covering kiln ramp and steady operation, ID fan speed changes, raw-mill start and stop, fuel-switch transitions, and planned maintenance derates. Each spectrum export should carry a note describing kiln speed, fan damper position, mill loading, and fuel type for that window. Label fuel type and production rate with each log entry, because kiln operating points change both harmonic current and reactive demand on the same feeders.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">A cement-plant RFQ record typically includes:<\/p>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\">Annotated single-line showing every meter position, breaker, and CT location.<\/li>\n<li style=\"margin:0 0 8px\">Harmonic spectra and RMS trends captured over full production shifts, not isolated tests.<\/li>\n<li style=\"margin:0 0 8px\">Operating notes tied to the kiln and fan operating point for every file in the data set.<\/li>\n<li style=\"margin:0 0 8px\">Inventory of existing capacitors, detuned banks, legacy filters, and VFD brands on the shared bus.<\/li>\n<li style=\"margin:0 0 8px\">Reactive-power and demand curves spanning at least one representative production cycle.<\/li>\n<\/ul>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Logging focus<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Data to attach<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">T\u1ea1i sao \u0111i\u1ec1u \u0111\u00f3 quan tr\u1ecdng<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Activity at the monitored kiln or fan feeder<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Order-by-order current, load state, CT reference<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Isolates kiln, fan, or mill contribution<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Activity at plant boundary<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Voltage\/current trends, transformer loading, upstream data<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Supports PCC-level mitigation scope<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Repeatability across production and fuel-change cycles<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Nhi\u1ec1u c\u1eeda s\u1ed5 v\u1eadn h\u00e0nh \u0111\u01b0\u1ee3c d\u00e1n nh\u00e3n<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Prevents quoting against atypical fuel or rate changes<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Thi\u1ebft b\u1ecb \u0111\u00e3 k\u1ebft n\u1ed1i<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ki\u1ec3m k\u00ea b\u1ea3o v\u1ec7, b\u00f9 \u0111\u1eafp m\u1ed9t d\u00f2ng<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Reveals resonance or interaction risks<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Quan tr\u1ecdng:<\/strong> Do not select APF or SVG capacity from a single kiln snapshot without time-stamped operating-state labels (Source: <a href=\"https:\/\/cnbygele.com\/vi\/blog\/vfd-harmonics-industrial-plants-apf-selection\/\">\u0110o s\u00f3ng h\u00e0i bi\u1ebfn t\u1ea7n (VFD) v\u00e0 l\u1ef1a ch\u1ecdn b\u1ed9 l\u1ecdc t\u00edch c\u1ef1c (APF)<\/a>). Kiln speed, fan loading, and mill duty change non-linear current together on shared cement-plant buses.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"keep-distortion-review-separate-from-process-and-emission-questions\">Keep distortion review separate from process and emission questions<\/h2>\n<figure class=\"wp-block-image size-large\" style=\"clear:both;display:block;margin:28px 0;float:none;width:100%;\"><img decoding=\"async\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/07\/reactive-power-and-harmonic-compensation-devices-overview-body-2.webp\" alt=\"Kiln and ID fan harmonic measurement context in cement plants\" class=\"alignnone size-large\" style=\"display:block;max-width:640px;height:auto;float:none;margin:0 auto;\" \/><\/figure>\n<p style=\"clear:both;margin:0;padding:0;height:0;line-height:0;\">&nbsp;<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Harmonic readings in cement plants sit beside clinker-quality targets, emission limits, and fuel-switching schedules. A distorted waveform does not, by itself, explain a process upset or an environmental exceedance. Treat each concern with its own evidence trail and acceptance criteria. Blending them early tends to produce oversized mitigation scopes or mismatched device selections.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">The <a href=\"https:\/\/standards.ieee.org\/ieee\/519\/5892\/\" rel=\"nofollow noopener\" target=\"_blank\">T\u1ed5ng quan v\u1ec1 IEEE 519<\/a> helps frame boundary discussions for harmonic control, yet every cement site still needs its own point of measurement, operating cases, and contractual language. Articles and vendor brochures cannot substitute for that project definition. Likewise, correlating a harmonic event with a kiln instability requires plant instrumentation and process engineering review beyond this measurement guide.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"choose-mitigation-paths-after-the-operating-log-is-complete\">Choose mitigation paths after the operating log is complete<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Shortlist equipment only when the logged data matches the stated objective and the integration envelope is understood. Kiln plants often carry mixed loads\u2014ID fans, mills, crushers, and auxiliary VFDs\u2014so the correct device category depends on whether harmonic-current reduction, reactive support, or both is required.<\/p>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Danh m\u1ee5c gi\u1ea3m nh\u1eb9<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">H\u1eefu \u00edch khi<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">X\u00e1c nh\u1eadn tr\u01b0\u1edbc khi g\u1eedi y\u00eau c\u1ea7u b\u00e1o gi\u00e1<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">AHF \/ APF<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Harmonic-current reduction at the cement plant medium-voltage or PCC boundary is documented and agreed<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Current spectra, CT plan, thermal path, protection, and acceptance test<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">SVG \/ ASVG<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">H\u1ed7 tr\u1ee3 c\u00f4ng su\u1ea5t ph\u1ea3n kh\u00e1ng nhanh l\u00e0 m\u1ee5c ti\u00eau ch\u00ednh<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Voltage profile, existing compensation, controls interface, and commissioning plan<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Tinh ch\u1ec9nh th\u1ee5 \u0111\u1ed9ng<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">M\u1ed9t nghi\u00ean c\u1ee9u h\u1ec7 th\u1ed1ng cho th\u1ea5y m\u1ed9t ch\u1ee9c n\u0103ng \u0111\u01b0\u1ee3c \u0111i\u1ec1u ch\u1ec9nh \u1ed5n \u0111\u1ecbnh ho\u1eb7c b\u1ecb l\u1ec7ch \u0111i\u1ec1u ch\u1ec9nh<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Resonance review, switching policy, and maintenance access<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Process or schedule change<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Operating-point shifts materially change demand<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Owner sign-off, production impact, and documented implementation<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\">Xem l\u1ea1i <a href=\"https:\/\/cnbygele.com\/vi\/product\/ahf-active-harmonic-filter-harmonic-control\/\">Trang B\u1ed9 l\u1ecdc s\u00f3ng h\u00e0i t\u00edch c\u1ef1c CNBYG AHF<\/a> alongside the logged data. The companion article on <a href=\"https:\/\/cnbygele.com\/vi\/blog\/vfd-harmonics-industrial-plants-apf-selection\/\">\u0110o s\u00f3ng h\u00e0i bi\u1ebfn t\u1ea7n (VFD) v\u00e0 l\u1ef1a ch\u1ecdn b\u1ed9 l\u1ecdc t\u00edch c\u1ef1c (APF)<\/a> walks through a similar measurement-first workflow in another heavy-industry setting.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"document-installation-and-acceptance-before-equipment-arrives\">Document installation and acceptance before equipment arrives<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Capture proposed bus connection, cable route, enclosure rating, cooling airflow, maintenance access, alarm points, and shutdown interlocks while the RFQ is still open. Cement plants impose dust, heat, and vibration constraints that affect cabinet placement and service intervals. Waiting until purchase-order stage to discover a routing conflict delays projects that already face production windows.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Post-installation checks should replay comparable kiln and fan states from the baseline log. Match meter placement, aggregation settings, and major-load lineup wherever possible. If acceptance targets a PCC metric, retain that boundary in the after-test plan. Shifting the logger to a different feeder without updating the objective can show improvement or regression that reflects test design rather than hardware performance. See <a href=\"https:\/\/cnbygele.com\/vi\/blog\/injection-molding-power-quality-servo-drives\/\">injection molding power quality and servo drives<\/a> for a parallel example of state-based acceptance in manufacturing environments.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"product-inquiry-checklist-for-cement-plants\">Product inquiry checklist for cement plants<\/h2>\n<figure class=\"wp-block-image size-large\" style=\"clear:both;display:block;margin:28px 0;float:none;width:100%;\"><img decoding=\"async\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/07\/reactive-power-and-harmonic-compensation-devices-overview-cover-2.webp\" alt=\"CNBYG AHF product context for cement plant VFD mitigation RFQs\" class=\"alignnone size-large\" style=\"display:block;max-width:640px;height:auto;float:none;margin:0 auto;\" \/><\/figure>\n<p style=\"clear:both;margin:0;padding:0;height:0;line-height:0;\">&nbsp;<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Send the single-line diagram, nominal voltage, transformer data, representative spectra, fuel and production schedule, major VFD inventory, existing compensation, protection schemes, preferred connection point, space and cooling notes, and communication expectations. State whether the decision concerns local feeder troubleshooting, plant-boundary assessment, harmonic-current mitigation, reactive-power support, or a combined review.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">CNBYG can evaluate whether its product line aligns with that scope. It should not be asked to guarantee kiln process stability, clinker quality, emission compliance, or a guaranteed harmonic result. Engage kiln operators, process engineers, and utility representatives when regulated or safety-critical constraints apply. Submit available records through the <a href=\"https:\/\/cnbygele.com\/vi\/contact-us\/\">Trang li\u00ean h\u1ec7 CNBYG<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"frequently-asked-questions\">C\u00e1c c\u00e2u h\u1ecfi th\u01b0\u1eddng g\u1eb7p<\/h2>\n<h3 style=\"margin:28px 0 12px\">Why is an operating-state log required for cement kiln VFD harmonics?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Kiln speed, fan loading, and mill duty change non-linear current together, so spectra without operating context cannot support a reliable mitigation scope.<\/p>\n<h3 style=\"margin:28px 0 12px\">Should kiln drives and ID fans be measured on one feeder or separately?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Measure the feeder or bus where the mitigation decision will apply, then add individual drive feeders when the bus data points to a specific source worth isolating.<\/p>\n<h3 style=\"margin:28px 0 12px\">Does this article confirm emission or clinker-quality outcomes from harmonic mitigation?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">No. Process, environmental, and product-quality decisions require plant-specific engineering beyond a harmonic measurement article.<\/p>\n<h3 style=\"margin:28px 0 12px\">M\u1ed9t ph\u00e9p \u0111o c\u00f3 \u0111\u1ee7 \u0111\u1ec3 l\u1ef1a ch\u1ecdn thi\u1ebft b\u1ecb gi\u1ea3m thi\u1ec3u hay kh\u00f4ng?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Rarely for cement plants. Logger placement, fuel type, kiln speed band, fan loading, and capture duration all decide whether a spectrum represents normal production.<\/p>\n<h3 style=\"margin:28px 0 12px\">C\u00f3 th\u1ec3 k\u00edch th\u01b0\u1edbc c\u1ee7a thi\u1ebft b\u1ecb gi\u1ea3m nh\u1eb9 \u0111\u01b0\u1ee3c t\u00ednh ch\u1ec9 d\u1ef1a tr\u00ean t\u1ea3i \u0111\u01b0\u1ee3c k\u1ebft n\u1ed1i hay kh\u00f4ng?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">No. Nameplate kVA and drive counts describe installation context, but capacity review needs measured harmonic behavior, operating logs, and the defined project objective.<\/p>\n<h3 style=\"margin:28px 0 12px\">B\u00e0i vi\u1ebft n\u00e0y c\u00f3 \u0111\u1ea3m b\u1ea3o k\u1ebft qu\u1ea3 v\u1ec1 m\u1eb7t tu\u00e2n th\u1ee7 ho\u1eb7c v\u1eadn h\u00e0nh kh\u00f4ng?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">No. Emission limits, clinker quality, network conditions, acceptance tests, and commissioning must be verified for the specific site and contract.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"references\">T\u00e0i li\u1ec7u tham kh\u1ea3o<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/standards.ieee.org\/ieee\/519\/5892\/\" rel=\"nofollow noopener\" target=\"_blank\">IEEE 519 \u2014 Th\u1ef1c h\u00e0nh Khuy\u1ebfn ngh\u1ecb v\u00e0 Y\u00eau c\u1ea7u v\u1ec1 Ki\u1ec3m so\u00e1t S\u00f3ng h\u00e0i trong H\u1ec7 th\u1ed1ng \u0110i\u1ec7n<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/www.nema.org\/standards\/view\/motors-and-generators\" rel=\"nofollow noopener\" target=\"_blank\">NEMA MG 1 \u2014 \u0110\u1ed9ng c\u01a1 v\u00e0 M\u00e1y ph\u00e1t \u0111i\u1ec7n<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/www.portlandcement.org\/docs\/default-source\/market-economics\/pca-market-intelligence.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Portland Cement Association \u2014 U.S. cement industry background resources<\/a><\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Cement plants combine kiln rotation drives, large ID fans, raw mills, and finish-grinding VFDs on shared buses where harmonic current shifts with production rate and fuel changes. Assessing cement kiln VFD harmonics requires an operating-state log that ties each spectrum capture to kiln speed, fan damper position, and mill loading rather than a single afternoon [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-2323","post","type-post","status-publish","format-standard","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":7}},"acf":[],"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/posts\/2323","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/comments?post=2323"}],"version-history":[{"count":1,"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/posts\/2323\/revisions"}],"predecessor-version":[{"id":2500,"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/posts\/2323\/revisions\/2500"}],"wp:attachment":[{"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/media?parent=2323"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/categories?post=2323"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/tags?post=2323"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}