{"id":2327,"date":"2026-08-03T15:00:00","date_gmt":"2026-08-03T07:00:00","guid":{"rendered":"https:\/\/cnbygele.com\/blog\/plastic-extrusion-line-vfd-harmonics-logging\/"},"modified":"2026-08-24T17:24:55","modified_gmt":"2026-08-24T09:24:55","slug":"plastic-extrusion-line-vfd-harmonics-logging","status":"publish","type":"post","link":"https:\/\/cnbygele.com\/vi\/blog\/plastic-extrusion-line-vfd-harmonics-logging\/","title":{"rendered":"Plastic Extrusion Line VFD Harmonics: Operating Logs"},"content":{"rendered":"<div class=\"b2b-article\">\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Plastics plants run extrusion lines where screw-speed setpoints, melt-temperature control, and changeovers shift VFD harmonic current on shared feeders.<\/strong> Assessing plastic extrusion VFD harmonics needs operating logs tied to recipe and line state rather than a single afternoon capture.<\/p>\n<nav class=\"b2b-toc\" style=\"background:#f5f8fa;padding:16px 20px;border-radius:8px;margin:0 0 24px\">\n<h2 id=\"contents\" style=\"margin:42px 0 14px;scroll-margin-top:96px\">M\u1ee5c l\u1ee5c<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"#bound-the-extruder-measurement-point\">Bound the extruder measurement point<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#keep-product-quality-separate-from-harmonic-scope\">Keep product quality separate from harmonic scope<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#mitigation-options-after-recipe-aware-logs\">Mitigation options after recipe-aware logs<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#assemble-an-extrusion-line-rfq-evidence-pack\">Assemble an extrusion-line RFQ evidence pack<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#installation-around-production-calendars\">Installation around production calendars<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#plastics-plant-inquiry-checklist\">Plastics-plant inquiry checklist<\/a><\/li>\n<\/ul>\n<\/nav>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"direct-answer\">Tr\u1ea3 l\u1eddi tr\u1ef1c ti\u1ebfp<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Plastics plants run extrusion lines where screw-speed setpoints, melt-temperature control, and changeovers shift VFD harmonic current on shared feeders. Assessing plastic extrusion VFD harmonics needs operating logs tied to recipe and line state rather than a single afternoon capture.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Melt-quality discussions and electrical distortion reviews should stay on separate tracks. CNBYG can discuss AHF\/APF context when measured harmonic current is the objective. It cannot establish product dimensional quality, melt stability, or a guaranteed harmonic result. Wider reading: <a href=\"https:\/\/cnbygele.com\/vi\/power-quality-system-guides\/\">H\u01b0\u1edbng d\u1eabn K\u1ef9 thu\u1eadt H\u1ec7 th\u1ed1ng Ch\u1ea5t l\u01b0\u1ee3ng \u0110i\u1ec7n<\/a>.<\/p>\n<figure class=\"wp-block-image size-large\" style=\"clear:both;display:block;margin:28px 0;float:none;width:100%;\"><img decoding=\"async\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/07\/reactive-power-automatic-compensation-controller-guide-product-1.webp\" alt=\"Plastic extrusion VFD harmonics operating-state logging\" class=\"alignnone size-large\" style=\"display:block;max-width:640px;height:auto;float:none;margin:0 auto;\" \/><\/figure>\n<p style=\"clear:both;margin:0;padding:0;height:0;line-height:0;\">&nbsp;<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"bound-the-extruder-measurement-point\">Bound the extruder measurement point<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Line feeders characterize screw and haul-off drives; the plant PCC answers a different question. Record CT details, recipe IDs, and line speed with each spectrum.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">For extruder main drives, melt pumps, and haul-off VFD groups, log startup heat, steady extrusion, recipe changeover, haul-off speed changes, and planned shutdown. Label resin recipe and line speed with each spectrum, because changeovers can produce brief peaks that matter for demand windows.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">M\u1ed9t h\u1ed3 s\u01a1 ti\u1ec1n RFQ th\u1ef1c t\u1ebf cho \u1ee9ng d\u1ee5ng n\u00e0y th\u01b0\u1eddng bao g\u1ed3m:<\/p>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\">Single-line showing extruder and haul-off feeders.<\/li>\n<li style=\"margin:0 0 8px\">Spectra across startup heat, steady run, and changeovers.<\/li>\n<li style=\"margin:0 0 8px\">Notes linked to the extrusion recipe and line speed state.<\/li>\n<li style=\"margin:0 0 8px\">Capacitor and filter inventory on the plastics bus.<\/li>\n<li style=\"margin:0 0 8px\">Demand trends over at least one full production day with changeovers.<\/li>\n<\/ul>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Extrusion log focus<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Y\u00eau c\u1ea7u cung c\u1ea5p b\u1eb1ng ch\u1ee9ng<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Quy\u1ebft \u0111\u1ecbnh \u0111\u01b0\u1ee3c h\u1ed7 tr\u1ee3<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Activity at the monitored extruder or line feeder<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">D\u1ea3i t\u1ea7n hi\u1ec7n t\u1ea1i, xu h\u01b0\u1edbng RMS, tr\u1ea1ng th\u00e1i t\u1ea3i, tham chi\u1ebfu CT<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u0110\u1eb7c t\u00ednh ngu\u1ed3n c\u1ee5c b\u1ed9<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ho\u1ea1t \u0111\u1ed9ng t\u1ea1i ranh gi\u1edbi h\u1ec7 th\u1ed1ng<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Xu h\u01b0\u1edbng \u0111i\u1ec7n \u00e1p\/d\u00f2ng \u0111i\u1ec7n, d\u1eef li\u1ec7u m\u00e1y bi\u1ebfn \u00e1p v\u00e0 th\u01b0\u1ee3ng ngu\u1ed3n<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ph\u1ea1m vi gi\u1ea3m thi\u1ec3u ranh gi\u1edbi<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Repeatability across production and changeover cycles<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Nhi\u1ec1u c\u1eeda s\u1ed5 v\u1eadn h\u00e0nh \u0111\u01b0\u1ee3c d\u00e1n nh\u00e3n<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">L\u1eadp k\u1ebf ho\u1ea1ch c\u00f4ng su\u1ea5t v\u00e0 v\u1eadn h\u00e0nh th\u1eed<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Thi\u1ebft b\u1ecb \u0111\u00e3 k\u1ebft n\u1ed1i<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ki\u1ec3m k\u00ea b\u1ea3o v\u1ec7, b\u00f9 \u0111\u1eafp m\u1ed9t d\u00f2ng<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u0110\u00e1nh gi\u00e1 t\u01b0\u01a1ng t\u00e1c v\u00e0 h\u1ed9i nh\u1eadp<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Quan tr\u1ecdng:<\/strong> Do not select APF capacity from a single steady-run snapshot without changeover labels (Source: <a href=\"https:\/\/cnbygele.com\/vi\/blog\/vfd-harmonics-industrial-plants-apf-selection\/\">\u0110o s\u00f3ng h\u00e0i bi\u1ebfn t\u1ea7n (VFD) v\u00e0 l\u1ef1a ch\u1ecdn b\u1ed9 l\u1ecdc t\u00edch c\u1ef1c (APF)<\/a>). Recipe transitions can create brief peaks that matter for demand windows.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"keep-product-quality-separate-from-harmonic-scope\">Keep product quality separate from harmonic scope<\/h2>\n<figure class=\"wp-block-image size-large\" style=\"clear:both;display:block;margin:28px 0;float:none;width:100%;\"><img decoding=\"async\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/07\/reactive-power-automatic-compensation-controller-guide-body-3.webp\" alt=\"Screw speed and changeover harmonic measurement context\" class=\"alignnone size-large\" style=\"display:block;max-width:640px;height:auto;float:none;margin:0 auto;\" \/><\/figure>\n<p style=\"clear:both;margin:0;padding:0;height:0;line-height:0;\">&nbsp;<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Dimensional drift and harmonic current can appear in the same shift without sharing a root cause. Maintain separate evidence trails and acceptance criteria.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Reference the <a href=\"https:\/\/standards.ieee.org\/ieee\/519\/5892\/\" rel=\"nofollow noopener\" target=\"_blank\">T\u1ed5ng quan v\u1ec1 IEEE 519<\/a> for boundary language, then define the plastics-plant measurement point in the RFQ.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Operators should also record melt-pump status and haul-off speed beside screw setpoints, because those auxiliaries change feeder coincidence. Keep a short note on resin lot identifiers next to the electrical log so process and electrical teams can reconcile timestamps during RFQ review. Those notes are short, but they keep extrusion changeover windows comparable for quotation and later commissioning follow-up on each site.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"mitigation-options-after-recipe-aware-logs\">Mitigation options after recipe-aware logs<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">AHF\/APF is relevant when harmonic-current reduction at the plastics-plant distribution bus or PCC is agreed. SVG may address reactive swings during speed changes. Passive filters need resonance checks against extrusion bus data.<\/p>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Danh m\u1ee5c gi\u1ea3m nh\u1eb9<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">H\u1eefu \u00edch khi<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">X\u00e1c nh\u1eadn tr\u01b0\u1edbc khi g\u1eedi y\u00eau c\u1ea7u b\u00e1o gi\u00e1<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">AHF \/ APF<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Harmonic-current reduction at the plastics-plant distribution bus or PCC is documented<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ph\u1ed5, k\u1ebf ho\u1ea1ch CT, \u0111\u01b0\u1eddng d\u1eabn nhi\u1ec7t, b\u1ea3o v\u1ec7, ki\u1ec3m tra nghi\u1ec7m thu<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">SVG \/ ASVG<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">H\u1ed7 tr\u1ee3 c\u00f4ng su\u1ea5t ph\u1ea3n kh\u00e1ng nhanh l\u00e0 m\u1ee5c ti\u00eau ch\u00ednh<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">H\u1ed3 s\u01a1 \u0111i\u1ec7n \u00e1p, thi\u1ebft b\u1ecb b\u00f9 hi\u1ec7n c\u00f3, \u0111i\u1ec1u khi\u1ec3n, v\u1eadn h\u00e0nh th\u1eed<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Tinh ch\u1ec9nh th\u1ee5 \u0111\u1ed9ng<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">M\u1ed9t nghi\u00ean c\u1ee9u h\u1ec7 th\u1ed1ng cho th\u1ea5y m\u1ed9t ch\u1ee9c n\u0103ng \u0111\u01b0\u1ee3c \u0111i\u1ec1u ch\u1ec9nh \u1ed5n \u0111\u1ecbnh ho\u1eb7c b\u1ecb l\u1ec7ch \u0111i\u1ec1u ch\u1ec9nh<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">\u0110\u00e1nh gi\u00e1 c\u1ed9ng h\u01b0\u1edfng, ch\u00ednh s\u00e1ch chuy\u1ec3n \u0111\u1ed5i, quy\u1ec1n truy c\u1eadp b\u1ea3o tr\u00ec<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Thay \u0111\u1ed5i v\u1eadn h\u00e0nh<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">L\u00ean l\u1ecbch ho\u1eb7c d\u00e0n d\u1ef1ng ca l\u00e0m vi\u1ec7c thay \u0111\u1ed5i \u0111\u00e1ng k\u1ec3 nhu c\u1ea7u<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ch\u1ee7 s\u1edf h\u1eefu ph\u00ea duy\u1ec7t v\u00e0 t\u00e0i li\u1ec7u h\u00f3a vi\u1ec7c tri\u1ec3n khai<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"assemble-an-extrusion-line-rfq-evidence-pack\">Assemble an extrusion-line RFQ evidence pack<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Before suppliers quote, assemble recipe-labeled spectra, changeover tables, CT notes, and a marked-up plastics single-line. Clarify whether the decision is local extruder troubleshooting, plant-bus assessment, or harmonic-current mitigation. Show steady-run and changeover windows side by side.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Require the quote to declare covered orders, heat-near-cabinet limits, and acceptance tests. Include headroom for future lines and list capacitors on the plastics bus. Name who labels recipes and who signs the acceptance checklist.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Add barrel-heat clearance notes, changeover outage slots, and a glossary of recipe codes so steady-run and transition files remain distinguishable. Include CT polarity checks, sample intervals, and a note describing which lines shared the plastics bus during each capture. Record expected spare headroom for future extruders and keep the acceptance checklist owner named before quotation begins.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Xem l\u1ea1i <a href=\"https:\/\/cnbygele.com\/vi\/product\/ahf-active-harmonic-filter-harmonic-control\/\">Trang B\u1ed9 l\u1ecdc s\u00f3ng h\u00e0i t\u00edch c\u1ef1c CNBYG AHF<\/a> using recipe-aware extrusion spectra. The welding-load guide on <a href=\"https:\/\/cnbygele.com\/vi\/blog\/vfd-harmonics-industrial-plants-apf-selection\/\">\u0110o s\u00f3ng h\u00e0i bi\u1ebfn t\u1ea7n (VFD) v\u00e0 l\u1ef1a ch\u1ecdn b\u1ed9 l\u1ecdc t\u00edch c\u1ef1c (APF)<\/a> illustrates another duty-cycle logging pattern.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"installation-around-production-calendars\">Installation around production calendars<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Capture cabinet placement away from hot barrels, cable routes, and changeover outage slots. Acceptance tests should replay recipe bands from the baseline log.<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">The related manufacturing scenario in <a href=\"https:\/\/cnbygele.com\/vi\/blog\/welding-robot-harmonic-profile-mitigation\/\">s\u00f3ng h\u00e0i c\u1ee7a robot h\u00e0n trong nh\u00e0 m\u00e1y \u00f4 t\u00f4<\/a> shows how recipe-aware logs support commissioning comparisons.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"plastics-plant-inquiry-checklist\">Plastics-plant inquiry checklist<\/h2>\n<figure class=\"wp-block-image size-large\" style=\"clear:both;display:block;margin:28px 0;float:none;width:100%;\"><img decoding=\"async\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/07\/reactive-power-automatic-compensation-controller-guide-cover-3.webp\" alt=\"CNBYG AHF product context for plastics plant VFD feeders\" class=\"alignnone size-large\" style=\"display:block;max-width:640px;height:auto;float:none;margin:0 auto;\" \/><\/figure>\n<p style=\"clear:both;margin:0;padding:0;height:0;line-height:0;\">&nbsp;<\/p>\n<p style=\"margin:0 0 16px;line-height:1.7\">Include single-line data, recipe-labeled spectra, drive inventory, compensation details, and space or cooling notes. CNBYG can review product-line fit and must not guarantee product dimensional quality, melt stability, or a guaranteed harmonic result. Use the <a href=\"https:\/\/cnbygele.com\/vi\/contact-us\/\">Trang li\u00ean h\u1ec7 CNBYG<\/a>.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"frequently-asked-questions\">C\u00e1c c\u00e2u h\u1ecfi th\u01b0\u1eddng g\u1eb7p<\/h2>\n<h3 style=\"margin:28px 0 12px\">Why log recipe and line speed with extrusion harmonics?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Screw torque and haul-off duty change with recipe, so unlabeled spectra cannot support a reliable mitigation scope.<\/p>\n<h3 style=\"margin:28px 0 12px\">Should each extruder have its own meter point?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Measure where the mitigation decision applies; add per-line feeders when bus data points to a specific source.<\/p>\n<h3 style=\"margin:28px 0 12px\">Does this article confirm product-quality outcomes from harmonic mitigation?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">No. Dimensional quality and melt stability require process engineering beyond a harmonic logging guide.<\/p>\n<h3 style=\"margin:28px 0 12px\">M\u1ed9t ph\u00e9p \u0111o c\u00f3 \u0111\u1ee7 \u0111\u1ec3 l\u1ef1a ch\u1ecdn thi\u1ebft b\u1ecb gi\u1ea3m thi\u1ec3u hay kh\u00f4ng?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Usually not for extrusion lines. Recipe bands, changeovers, and capture length determine whether capacity talk is justified.<\/p>\n<h3 style=\"margin:28px 0 12px\">Can mitigation equipment be sized from extruder nameplate kW alone?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">No. Nameplate kW is context; measured spectra and operating logs set the capacity basis.<\/p>\n<h3 style=\"margin:28px 0 12px\">B\u00e0i vi\u1ebft n\u00e0y c\u00f3 \u0111\u1ea3m b\u1ea3o k\u1ebft qu\u1ea3 v\u1ec1 m\u1eb7t tu\u00e2n th\u1ee7 ho\u1eb7c v\u1eadn h\u00e0nh kh\u00f4ng?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">No. Product quality, network conditions, and commissioning remain plant-specific.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"references\">T\u00e0i li\u1ec7u tham kh\u1ea3o<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/standards.ieee.org\/ieee\/519\/5892\/\" rel=\"nofollow noopener\" target=\"_blank\">IEEE 519 harmonic-control context for plastic extrusion vfd harmonics projects<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/www.nema.org\/standards\/view\/motors-and-generators\" rel=\"nofollow noopener\" target=\"_blank\">NEMA MG 1 motor-system background for plastic extrusion vfd harmonics reviews<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/www.energy.gov\/eere\/amo\/industrial-technologies-office\" rel=\"nofollow noopener\" target=\"_blank\">United States DOE Industrial Technologies Office resources<\/a><\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Plastics plants run extrusion lines where screw-speed setpoints, melt-temperature control, and changeovers shift VFD harmonic current on shared feeders. Assessing plastic extrusion VFD harmonics needs operating logs tied to recipe and line state rather than a single afternoon capture. Contents Bound the extruder measurement point Keep product quality separate from harmonic scope Mitigation options after [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-2327","post","type-post","status-publish","format-standard","hentry","category-blog"],"blocksy_meta":{"styles_descriptor":{"styles":{"desktop":"","tablet":"","mobile":""},"google_fonts":[],"version":7}},"acf":[],"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/posts\/2327","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/comments?post=2327"}],"version-history":[{"count":1,"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/posts\/2327\/revisions"}],"predecessor-version":[{"id":2504,"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/posts\/2327\/revisions\/2504"}],"wp:attachment":[{"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/media?parent=2327"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/categories?post=2327"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/tags?post=2327"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}