{"id":1688,"date":"2026-05-21T11:53:39","date_gmt":"2026-05-21T03:53:39","guid":{"rendered":"https:\/\/w6pown520g.wpdns.site\/?post_type=product&#038;p=1688"},"modified":"2026-06-29T16:02:44","modified_gmt":"2026-06-29T08:02:44","slug":"ahf-active-harmonic-filter-harmonic-control-2","status":"publish","type":"product","link":"https:\/\/cnbygele.com\/vi\/product\/ahf-active-harmonic-filter-harmonic-control-2\/","title":{"rendered":"AHF Active Harmonic Filter Harmonic Control"},"content":{"rendered":"<h2>M\u00f4 t\u1ea3 s\u1ea3n ph\u1ea9m<\/h2>\n<p>The AHF active power filter can effectively monitor harmonics and extract harmonic currents from them. The device emits inverse harmonic currents through IGBT, completely suppressing harmonics at the device connection point, and avoiding greater losses caused by harmonics flowing into circuit breakers or transformers. At the same time, the device can also manage reactive power and three-phase imbalance phenomena, truly achieving intelligent integrated power quality management. AHF can effectively filter out 2\u201350 harmonics.<\/p>\n<ul>\n<li>Improve the quality of power supply, improve the reliability of equipment operation, and reduce economic losses caused by equipment malfunctions<\/li>\n<li>Reduce line heating, reduce insulation aging, and improve electrical safety and reliability<\/li>\n<li>Reduce the resonance probability of compensation capacitors and improve electricity safety; Meet the requirements of national standards<\/li>\n<li>Reduce electromagnetic interference caused by harmonics and ensure the normal operation of the communication system<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-1609 size-full\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control.webp\" alt=\"\" width=\"1500\" height=\"872\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control.webp 1500w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-300x174.webp 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-1024x595.webp 1024w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-768x446.webp 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-600x349.webp 600w\" sizes=\"auto, (max-width: 1500px) 100vw, 1500px\" \/><\/p>\n<p><strong><b>AHF principle of operation:<\/b><\/strong><\/p>\n<p>The AHF operates by continuously monitoring the load current in real time using external current transformers (CTs). Its internal high-speed digital signal processor (DSP) extracts harmonic components and reactive current from the detected waveform, then generates a precise, opposite-phase compensation current. This compensating current is injected back into the power line through an insulated-gate bipolar transistor (IGBT) inverter, effectively canceling the harmonics and correcting the power factor. As a result, the AHF ensures that only the fundamental current at nearunity power factor is drawn from the utility, delivering clean, stable power to the grid.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-945\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.AHF-Active-Harmonic-Filter-Harmonic-Control.webp\" alt=\"\" width=\"1500\" height=\"1693\" \/><\/p>\n<h2><strong><b>Wall-Mounted AHF<\/b><\/strong><\/h2>\n<p><strong>Technical Specification<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"164\">TYPE<\/td>\n<td width=\"122\">Series 230V<\/td>\n<td width=\"122\">Series 400V<\/td>\n<td width=\"122\">Series 500V<\/td>\n<td width=\"122\">Series 690V<\/td>\n<\/tr>\n<tr>\n<td>C\u00f4ng su\u1ea5t<\/td>\n<td width=\"122\">30A\/50A\/75A<br \/>\n100A\/150A\/200A<\/td>\n<td width=\"122\">30A\/50A\/75A<br \/>\n100A\/150A\/200A<\/td>\n<td width=\"122\">30A\/50A\/75A<br \/>\n100A\/150A\/200A<\/td>\n<td width=\"122\">30A\/50A\/75A<br \/>\n100A\/150A<\/td>\n<\/tr>\n<tr>\n<td>\u0110i\u1ec7n \u00e1p<\/td>\n<td>230V(+\/-20%)<\/td>\n<td>400V(+\/-20%)<\/td>\n<td>500V(+\/-20%)<\/td>\n<td>690V(+\/-20%)<\/td>\n<\/tr>\n<tr>\n<td>T\u1ea7n su\u1ea5t<\/td>\n<td colspan=\"4\">50Hz(+\/-5%)<\/td>\n<\/tr>\n<tr>\n<td>Phase<\/td>\n<td colspan=\"4\">3 Phases<\/td>\n<\/tr>\n<tr>\n<td>Th\u1eddi gian ph\u1ea3n h\u1ed3i<\/td>\n<td colspan=\"4\">&lt;5ms<\/td>\n<\/tr>\n<tr>\n<td>Current transformer<\/td>\n<td colspan=\"4\">150\uff1a5~10,000\uff1a5<\/td>\n<\/tr>\n<tr>\n<td>Efficiency &amp; Losses<\/td>\n<td colspan=\"4\">Efficiency \u226597% (3ph), \u226415 W\/A Loss<\/td>\n<\/tr>\n<tr>\n<td>Function<\/td>\n<td colspan=\"4\">Elimination of harmonic<\/td>\n<\/tr>\n<tr>\n<td>Number of modules<\/td>\n<td colspan=\"4\" width=\"491\">No limitations. One monitoring module can be equipped with 32 actuator\/execution modules<\/td>\n<\/tr>\n<tr>\n<td>Communications protocol<\/td>\n<td colspan=\"4\">Modbus, TCP\/IP, CAN<\/td>\n<\/tr>\n<tr>\n<td>Altitude above sea level<\/td>\n<td colspan=\"4\">&lt; 2000m<\/td>\n<\/tr>\n<tr>\n<td>Nhi\u1ec7t \u0111\u1ed9<\/td>\n<td colspan=\"4\">-20~+50C<\/td>\n<\/tr>\n<tr>\n<td>Humidity<\/td>\n<td colspan=\"4\">&lt;90%<\/td>\n<\/tr>\n<tr>\n<td>Pollution Degree<\/td>\n<td colspan=\"4\">Below Level 2<\/td>\n<\/tr>\n<tr>\n<td>Compensation mode<\/td>\n<td colspan=\"4\" width=\"491\">Harmonic suppression\/reactive power compensation\/unbalance compensation,<\/p>\n<p>11 modes in any combination<\/td>\n<\/tr>\n<tr>\n<td>Noise<\/td>\n<td>&lt;50dB<\/td>\n<td>&lt;60dB<\/td>\n<td colspan=\"2\">&lt;65dB<\/td>\n<\/tr>\n<tr>\n<td>Installation method<\/td>\n<td colspan=\"4\">Wall Mounting<\/td>\n<\/tr>\n<tr>\n<td>Standards compliance<\/td>\n<td colspan=\"4\">IEEE519\u3001IEC6100-3-6\u3001ER G5\/4\u3001CE\uff0cEMC Compliance: EN 61000-6-4 Class A<\/td>\n<\/tr>\n<tr>\n<td>Degree of protection<\/td>\n<td colspan=\"4\">IP20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><b>Product Size Information<\/b><\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-947\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/4.AHF-Active-Harmonic-Filter-Harmonic-Control.webp\" alt=\"\" width=\"1500\" height=\"778\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"112\">M\u00f4 h\u00ecnh<\/td>\n<td width=\"213\">Capacity(kvar)<\/td>\n<td width=\"79\">Voltage(V)<\/td>\n<td width=\"117\">Size(W*H*D)(mm)<\/td>\n<td width=\"140\">Cooling<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.23-3L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>230V<\/td>\n<td>480x570x175<\/td>\n<td>Forced Air Cooling<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.23-3L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>230V<\/td>\n<td>480x570x175<\/td>\n<td>Forced Air Cooling<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.4-4L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>400V<\/td>\n<td>480x570x175<\/td>\n<td>Forced Air Cooling<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.4-4L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>400V<\/td>\n<td>480x570x175<\/td>\n<td>Forced Air Cooling<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.5-4L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>500V<\/td>\n<td>480x570x175<\/td>\n<td>Forced Air Cooling<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.69-4L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A<\/td>\n<td>690V<\/td>\n<td>480x570x175<\/td>\n<td>Forced Air Cooling<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The specification is limited to standard types; other dimensions are available upon request.<\/p>\n<h2><strong><b>Rack Mounted AHF<\/b><\/strong><\/h2>\n<p><strong>Technical Specification<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"165\">TYPE<\/td>\n<td width=\"123\">Series 230V<\/td>\n<td width=\"123\">Series 400V<\/td>\n<td width=\"123\">Series 500V<\/td>\n<td width=\"123\">Series 690V<\/td>\n<\/tr>\n<tr>\n<td>C\u00f4ng su\u1ea5t<\/td>\n<td width=\"123\">30A\/50A\/75A<br \/>\n100A\/150A\/200A<\/td>\n<td width=\"123\">30A\/50A\/75A<br \/>\n100A\/150A\/200A<\/td>\n<td width=\"123\">30A\/50A\/75A<br \/>\n100A\/150A\/200A<\/td>\n<td width=\"123\">30A\/50A\/75A<br \/>\n100A\/150A<\/td>\n<\/tr>\n<tr>\n<td>\u0110i\u1ec7n \u00e1p<\/td>\n<td>230V(+\/-20%)<\/td>\n<td>400V(+\/-20%)<\/td>\n<td>500V(+\/-20%)<\/td>\n<td>690V(+\/-20%)<\/td>\n<\/tr>\n<tr>\n<td>T\u1ea7n su\u1ea5t<\/td>\n<td colspan=\"4\">50Hz(+\/-5%)<\/td>\n<\/tr>\n<tr>\n<td>Phase<\/td>\n<td colspan=\"4\">3 Phases<\/td>\n<\/tr>\n<tr>\n<td>Th\u1eddi gian ph\u1ea3n h\u1ed3i<\/td>\n<td colspan=\"4\">&lt;5ms<\/td>\n<\/tr>\n<tr>\n<td>Current transformer<\/td>\n<td colspan=\"4\">150\uff1a5~10,000\uff1a5<\/td>\n<\/tr>\n<tr>\n<td>Efficiency &amp; Losses<\/td>\n<td colspan=\"4\">Efficiency \u226597% (3ph), \u226415 W\/A Loss<\/td>\n<\/tr>\n<tr>\n<td>Function<\/td>\n<td colspan=\"4\">Elimination of harmonic<\/td>\n<\/tr>\n<tr>\n<td>Number of modules<\/td>\n<td colspan=\"4\" width=\"493\">No limitations. One monitoring module can be equipped with 32 actuator\/execution modules<\/td>\n<\/tr>\n<tr>\n<td>Communications protocol<\/td>\n<td colspan=\"4\">Modbus, TCP\/IP, CAN<\/td>\n<\/tr>\n<tr>\n<td>Altitude above sea level<\/td>\n<td colspan=\"4\">&lt; 2000m<\/td>\n<\/tr>\n<tr>\n<td>Nhi\u1ec7t \u0111\u1ed9<\/td>\n<td colspan=\"4\">-20~+50C<\/td>\n<\/tr>\n<tr>\n<td>Humidity<\/td>\n<td colspan=\"4\">&lt;90%<\/td>\n<\/tr>\n<tr>\n<td>Pollution Degree<\/td>\n<td colspan=\"4\">Below Level 2<\/td>\n<\/tr>\n<tr>\n<td>Compensation mode<\/td>\n<td colspan=\"4\" width=\"493\">Harmonic suppression\/reactive power compensation\/unbalance compensation, 11 modes in any combination<\/td>\n<\/tr>\n<tr>\n<td>Noise<\/td>\n<td>&lt;50dB<\/td>\n<td>&lt;60dB<\/td>\n<td colspan=\"2\">&lt;65dB<\/td>\n<\/tr>\n<tr>\n<td>Installation method<\/td>\n<td colspan=\"4\">Rack Mounting<\/td>\n<\/tr>\n<tr>\n<td>Standards compliance<\/td>\n<td colspan=\"4\">IEEE519\u3001IEC6100-3-6\u3001ER G5\/4\u3001CE\uff0cEMC Compliance: EN 61000-6-4 Class A<\/td>\n<\/tr>\n<tr>\n<td>Degree of protection<\/td>\n<td colspan=\"4\">IP20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong><b>Product Size Information<\/b><\/strong><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1610\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.1-AHF-Active-Harmonic-Filter-Harmonic-Control.webp\" alt=\"\" width=\"1500\" height=\"765\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.1-AHF-Active-Harmonic-Filter-Harmonic-Control.webp 1500w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.1-AHF-Active-Harmonic-Filter-Harmonic-Control-300x153.webp 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.1-AHF-Active-Harmonic-Filter-Harmonic-Control-1024x522.webp 1024w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.1-AHF-Active-Harmonic-Filter-Harmonic-Control-768x392.webp 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.1-AHF-Active-Harmonic-Filter-Harmonic-Control-600x306.webp 600w\" sizes=\"auto, (max-width: 1500px) 100vw, 1500px\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"112\">M\u00f4 h\u00ecnh<\/td>\n<td width=\"208\">Capacity(kvar)<\/td>\n<td width=\"81\">Voltage(V)<\/td>\n<td width=\"120\">Size(W*H*D)(mm)<\/td>\n<td width=\"143\">Cooling<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.23-3L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>230V<\/td>\n<td>480x570x175<\/td>\n<td>Forced Air Cooling<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.23-3L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>230V<\/td>\n<td>480x570x175<\/td>\n<td>Forced Air Cooling<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.4-4L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>400V<\/td>\n<td>480x570x175<\/td>\n<td>Forced Air Cooling<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.4-4L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>400V<\/td>\n<td>480x570x175<\/td>\n<td>Forced Air Cooling<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.5-4L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A\/200A<\/td>\n<td>500V<\/td>\n<td>480x570x175<\/td>\n<td>Forced Air Cooling<\/td>\n<\/tr>\n<tr>\n<td>AHF-0.69-4L-W<\/td>\n<td>30A\/50A\/75A\/100A\/150A<\/td>\n<td>690V<\/td>\n<td>480x570x175<\/td>\n<td>Forced Air Cooling<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The specification is limited to standard types; other dimensions are available upon request.<\/p>","protected":false},"excerpt":{"rendered":"<p>AHF active harmonic filters improve power quality and equipment reliability through harmonic control, reducing economic losses caused by equipment failures. They reduce line heating and insulation aging, enhancing electrical safety and reliability, while also reducing the resonance probability of compensation capacitors, ensuring power safety and compliance with national standards. The device reduces electromagnetic interference caused by harmonics, ensuring the normal operation of communication systems.<\/p>","protected":false},"featured_media":1606,"template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[33,30],"product_tag":[],"class_list":["post-1688","product","type-product","status-publish","has-post-thumbnail","product_cat-power-quality-system","product_cat-products","first","instock","downloadable","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/product\/1688","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/media\/1606"}],"wp:attachment":[{"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/media?parent=1688"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/product_brand?post=1688"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/product_cat?post=1688"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/product_tag?post=1688"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}