{"id":1689,"date":"2026-05-21T11:55:14","date_gmt":"2026-05-21T03:55:14","guid":{"rendered":"https:\/\/w6pown520g.wpdns.site\/?post_type=product&#038;p=1689"},"modified":"2026-06-29T16:02:23","modified_gmt":"2026-06-29T08:02:23","slug":"svg-static-var-generators-2","status":"publish","type":"product","link":"https:\/\/cnbygele.com\/vi\/product\/svg-static-var-generators-2\/","title":{"rendered":"M\u00e1y ph\u00e1t c\u00f4ng su\u1ea5t ph\u1ea3n kh\u00e1ng t\u0129nh SVG"},"content":{"rendered":"<h2>M\u00f4 t\u1ea3 s\u1ea3n ph\u1ea9m<\/h2>\n<p>The consumption of reactive power involves additional charges levied by operators, which is why the use of an SVG compensator effectively reduces electricity bills, completely eliminating the costs associated with reactive power consumption.<\/p>\n<ul>\n<li>Immediate and precise reactive power compensation<\/li>\n<li>Active harmonic suppression<\/li>\n<li>Dynamic adaptation to changing operating conditions<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1609\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control.webp\" alt=\"\" width=\"1500\" height=\"872\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control.webp 1500w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-300x174.webp 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-1024x595.webp 1024w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-768x446.webp 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/1.1-AHF-Active-Harmonic-Filter-Harmonic-Control-600x349.webp 600w\" sizes=\"auto, (max-width: 1500px) 100vw, 1500px\" \/><\/p>\n<p><strong><b>SVG principle of operation<\/b><\/strong><\/p>\n<p>The operating principle of the SVG compensator is based on continuously monitoring the current and voltage waveforms in the network.<\/p>\n<p>When the system detects phase deviations caused by the nature of the load, it immediately generates a compensating current with the opposite characteristics. Thanks to the use of German IGBT modules from Infineon and precise PWM control, the device corrects the power factor in real time, compensating both inductive and capacitive reactive power. This active mode of operation ensures the maintenance of ideal power supply parameters regardless of load fluctuations, guaranteeing exceptional reliability and the highest precision of compensation.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1613\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1.webp\" alt=\"\" width=\"2480\" height=\"2339\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1.webp 2480w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-300x283.webp 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-1024x966.webp 1024w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-768x724.webp 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-1536x1449.webp 1536w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-2048x1932.webp 2048w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/2.SVG-reactive-power-compensators-1-600x566.webp 600w\" sizes=\"auto, (max-width: 2480px) 100vw, 2480px\" \/><\/p>\n<h2><strong><b>Wall-Mounted SVG<\/b><\/strong><\/h2>\n<p><strong>Technical Specification<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"174\">TYPE<\/td>\n<td width=\"149\">Series 230V<\/td>\n<td width=\"155\">Series 400V<\/td>\n<td width=\"91\">Series 500V<\/td>\n<td width=\"91\">Series 690V<\/td>\n<\/tr>\n<tr>\n<td>C\u00f4ng su\u1ea5t<\/td>\n<td width=\"149\">20kVar\/30kVar\/35kVar\/<br \/>\n50kVar\/70kVar\/100kVar<\/td>\n<td width=\"155\">10kVar\/15kVar\/20kVar\/<br \/>\n30kVar\/35kVar\/50kVar\/<br \/>\n75kVar\/100kVar\/150kVar<\/td>\n<td>85kVar<\/td>\n<td>120kVar<\/td>\n<\/tr>\n<tr>\n<td>\u0110i\u1ec7n \u00e1p<\/td>\n<td>230V(+\/-20%)<\/td>\n<td>400V(+\/-20%)<\/td>\n<td>500V(+\/-20%)<\/td>\n<td>690V(+\/-20%)<\/td>\n<\/tr>\n<tr>\n<td>T\u1ea7n su\u1ea5t<\/td>\n<td colspan=\"4\">50Hz(+\/-5%)<\/td>\n<\/tr>\n<tr>\n<td>Phase<\/td>\n<td>1 Phase<\/td>\n<td colspan=\"3\">3 Phases<\/td>\n<\/tr>\n<tr>\n<td>Th\u1eddi gian ph\u1ea3n h\u1ed3i<\/td>\n<td colspan=\"4\">&lt;10ms<\/td>\n<\/tr>\n<tr>\n<td>compensation factor<\/td>\n<td colspan=\"4\">&gt;95%<\/td>\n<\/tr>\n<tr>\n<td>Device efficiency<\/td>\n<td colspan=\"4\">&gt;97%<\/td>\n<\/tr>\n<tr>\n<td>Switching frequency<\/td>\n<td>32kHz<\/td>\n<td>16kHz<\/td>\n<td>12,8kHz<\/td>\n<td>12,8kHz<\/td>\n<\/tr>\n<tr>\n<td>Function<\/td>\n<td colspan=\"4\">B\u00f9 c\u00f4ng su\u1ea5t ph\u1ea3n kh\u00e1ng<\/td>\n<\/tr>\n<tr>\n<td>Number of modules<\/td>\n<td colspan=\"4\" width=\"488\">No limitations. One monitoring module can be<br \/>\nequipped with 32 actuator\/execution modules<\/td>\n<\/tr>\n<tr>\n<td>Communication<\/td>\n<td colspan=\"4\">Dual-channel RS485 (Support for wireless WiFi\/GPRS communication)<\/td>\n<\/tr>\n<tr>\n<td>Altitude above sea level<\/td>\n<td colspan=\"4\">&lt; 2000m<\/td>\n<\/tr>\n<tr>\n<td>Nhi\u1ec7t \u0111\u1ed9<\/td>\n<td colspan=\"4\">-20~+50C<\/td>\n<\/tr>\n<tr>\n<td>Humidity<\/td>\n<td colspan=\"4\">&lt;90%<\/td>\n<\/tr>\n<tr>\n<td>Pollution Degree<\/td>\n<td colspan=\"4\">Below Level 2<\/td>\n<\/tr>\n<tr>\n<td>Protections<\/td>\n<td colspan=\"4\" width=\"488\">Overload,Over\u00a0current,Over\u00a0voltage,Against supply network asymmetry,<br \/>\nThermal\/Over\u00a0temperature,Frequency fluctuations Short-circuit<\/td>\n<\/tr>\n<tr>\n<td>Noise<\/td>\n<td>&lt;50dB<\/td>\n<td>&lt;60dB<\/td>\n<td colspan=\"2\">&lt;65dB<\/td>\n<\/tr>\n<tr>\n<td>Installation method<\/td>\n<td colspan=\"4\">Wall Mounting<\/td>\n<\/tr>\n<tr>\n<td>Connection<\/td>\n<td colspan=\"4\">From the top (Wall-mounted)<\/td>\n<\/tr>\n<tr>\n<td>Degree of protection<\/td>\n<td colspan=\"4\">IP20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong><b>Product Size Information<\/b><\/strong><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-962\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/4.SVG.webp\" alt=\"\" width=\"1500\" height=\"816\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"101\">M\u00f4 h\u00ecnh<\/td>\n<td width=\"246\">Capacity(kvar)<\/td>\n<td width=\"71\">Voltage(V)<\/td>\n<td width=\"113\">Size(W*H*D)(mm)<\/td>\n<td width=\"133\">Cooling<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.23-2L-W<\/td>\n<td>20Kvar\/30Kvar\/35Kvar<\/td>\n<td>230V<\/td>\n<td>380x424x88<\/td>\n<td>Forced Air Cooling<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.23-2L-W<\/td>\n<td>50Kvar\/70Kvar\/100Kvar<\/td>\n<td>230V<\/td>\n<td>500x550x130<\/td>\n<td>Forced Air Cooling<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.4-4L-W<\/td>\n<td>10Kvar\/15Kvar\/20Kvar\/30Kvar\/35Kvar<\/td>\n<td>400V<\/td>\n<td>380x424x88<\/td>\n<td>Forced Air Cooling<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.4-4L-W<\/td>\n<td>50Kvar\/75Kvar\/100Kvar\/150Kvar<\/td>\n<td>400V<\/td>\n<td>500x550x130<\/td>\n<td>Forced Air Cooling<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.5-4L-W<\/td>\n<td>85Kvar<\/td>\n<td>500V<\/td>\n<td>500x550x130<\/td>\n<td>Forced Air Cooling<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.69-4L-W<\/td>\n<td>120Kvar<\/td>\n<td>690V<\/td>\n<td>500x550x130<\/td>\n<td>Forced Air Cooling<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The specification is limited to standard types; other dimensions are available upon request.<\/p>\n<h2><strong><b>Rack-mounted SVG<\/b><\/strong><\/h2>\n<p><strong>Technical Specification<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"183\">TYPE<\/td>\n<td width=\"146\">Series 230V<\/td>\n<td width=\"153\">Series 400V<\/td>\n<td width=\"93\">Series 500V<\/td>\n<td width=\"93\">Series 690V<\/td>\n<\/tr>\n<tr>\n<td>C\u00f4ng su\u1ea5t<\/td>\n<td width=\"146\">20kVar\/30kVar\/35kVar\/<br \/>\n50kVar\/70kVar\/100kVar<\/td>\n<td width=\"153\">10kVar\/15kVar\/20kVar\/<br \/>\n30kVar\/35kVar\/50kVar\/<br \/>\n75kVar\/100kVar\/150kVar<\/td>\n<td>85kVar<\/td>\n<td>120kVar<\/td>\n<\/tr>\n<tr>\n<td>\u0110i\u1ec7n \u00e1p<\/td>\n<td>230V(+\/-20%)<\/td>\n<td>400V(+\/-20%)<\/td>\n<td>500V(+\/-20%)<\/td>\n<td>690V(+\/-20%)<\/td>\n<\/tr>\n<tr>\n<td>T\u1ea7n su\u1ea5t<\/td>\n<td colspan=\"4\">50Hz(+\/-5%)<\/td>\n<\/tr>\n<tr>\n<td>Phase<\/td>\n<td>1 Phase<\/td>\n<td colspan=\"3\">3 Phases<\/td>\n<\/tr>\n<tr>\n<td>Th\u1eddi gian ph\u1ea3n h\u1ed3i<\/td>\n<td colspan=\"4\">&lt;10ms<\/td>\n<\/tr>\n<tr>\n<td>compensation factor<\/td>\n<td colspan=\"4\">&gt;95%<\/td>\n<\/tr>\n<tr>\n<td>Device efficiency<\/td>\n<td colspan=\"4\">&gt;97%<\/td>\n<\/tr>\n<tr>\n<td>Switching frequency<\/td>\n<td>32kHz<\/td>\n<td>16kHz<\/td>\n<td>12,8kHz<\/td>\n<td>12,8kHz<\/td>\n<\/tr>\n<tr>\n<td>Function<\/td>\n<td colspan=\"4\">B\u00f9 c\u00f4ng su\u1ea5t ph\u1ea3n kh\u00e1ng<\/td>\n<\/tr>\n<tr>\n<td>Number of modules<\/td>\n<td colspan=\"4\" width=\"487\">No limitations. One monitoring module can be<br \/>\nequipped with 32 actuator\/execution modules<\/td>\n<\/tr>\n<tr>\n<td>Communication<\/td>\n<td colspan=\"4\">Dual-channel RS485 (Support for wireless WiFi\/GPRS communication)<\/td>\n<\/tr>\n<tr>\n<td>Altitude above sea level<\/td>\n<td colspan=\"4\">&lt; 2000m<\/td>\n<\/tr>\n<tr>\n<td>Nhi\u1ec7t \u0111\u1ed9<\/td>\n<td colspan=\"4\">-20~+50C<\/td>\n<\/tr>\n<tr>\n<td>Humidity<\/td>\n<td colspan=\"4\">&lt;90%<\/td>\n<\/tr>\n<tr>\n<td>Pollution Degree<\/td>\n<td colspan=\"4\">Below Level 2<\/td>\n<\/tr>\n<tr>\n<td>Protections<\/td>\n<td colspan=\"4\" width=\"487\">Overload,Over current,Over voltage,Against supply network asymmetry,<br \/>\nThermal\/Over temperature,Frequency fluctuations Short-circuit<\/td>\n<\/tr>\n<tr>\n<td>Noise<\/td>\n<td>&lt;50dB<\/td>\n<td>&lt;60dB<\/td>\n<td colspan=\"2\">&lt;65dB<\/td>\n<\/tr>\n<tr>\n<td>Installation method<\/td>\n<td colspan=\"4\">Rack-mount<\/td>\n<\/tr>\n<tr>\n<td>Connection<\/td>\n<td colspan=\"4\">From the back (Rack)<\/td>\n<\/tr>\n<tr>\n<td>Degree of protection<\/td>\n<td colspan=\"4\">IP20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><b>Product Size Information<\/b><\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1615\" src=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators.webp\" alt=\"\" width=\"1500\" height=\"765\" srcset=\"https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators.webp 1500w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators-300x153.webp 300w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators-1024x522.webp 1024w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators-768x392.webp 768w, https:\/\/cnbygele.com\/wp-content\/uploads\/2026\/04\/6.SVG-reactive-power-compensators-600x306.webp 600w\" sizes=\"auto, (max-width: 1500px) 100vw, 1500px\" \/><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"101\">M\u00f4 h\u00ecnh<\/td>\n<td width=\"246\">Capacity(kvar)<\/td>\n<td width=\"71\">Voltage(V)<\/td>\n<td width=\"113\">Size(W*H*D)(mm)<\/td>\n<td width=\"133\">Cooling<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.23-2L-R<\/td>\n<td>20Kvar\/30Kvar\/35Kvar<\/td>\n<td>230V<\/td>\n<td>380x424x88<\/td>\n<td>Forced Air Cooling<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.23-2L-R<\/td>\n<td>50Kvar\/70Kvar\/100Kvar<\/td>\n<td>230V<\/td>\n<td>500x550x130<\/td>\n<td>Forced Air Cooling<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.4-4L-R<\/td>\n<td>10Kvar\/15Kvar\/20Kvar\/30Kvar\/35Kvar<\/td>\n<td>400V<\/td>\n<td>380x424x88<\/td>\n<td>Forced Air Cooling<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.4-4L-R<\/td>\n<td>50Kvar\/75Kvar\/100Kvar\/150Kvar<\/td>\n<td>400V<\/td>\n<td>500x550x130<\/td>\n<td>Forced Air Cooling<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.5-4L-R<\/td>\n<td>85Kvar<\/td>\n<td>500V<\/td>\n<td>500x550x130<\/td>\n<td>Forced Air Cooling<\/td>\n<\/tr>\n<tr>\n<td>SVG-0.69-4L-R<\/td>\n<td>120Kvar<\/td>\n<td>690V<\/td>\n<td>500x550x130<\/td>\n<td>Forced Air Cooling<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The specification is limited to standard types; other dimensions are available upon request.<\/p>","protected":false},"excerpt":{"rendered":"<p>Our static reactive power compensators (SVG) provide an optimal solution for issues related to network stability, power factor, and reactive power demand in various industrial applications. The devices feature extremely fast operation, compact design, and exceptional cost efficiency, ensuring immediate response to disturbances in medium- and low-voltage power systems. By compensating reactive power, they significantly increase the lifespan of installations, enhance the reliability of production processes, improve system performance, and reduce transmission losses, all while meeting the most stringent energy quality standards.<\/p>","protected":false},"featured_media":1606,"template":"","meta":{"_acf_changed":false,"_gspb_post_css":""},"product_brand":[],"product_cat":[33,30],"product_tag":[],"class_list":["post-1689","product","type-product","status-publish","has-post-thumbnail","product_cat-power-quality-system","product_cat-products","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/product\/1689","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/media\/1606"}],"wp:attachment":[{"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/media?parent=1689"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/product_brand?post=1689"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/product_cat?post=1689"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnbygele.com\/vi\/wp-json\/wp\/v2\/product_tag?post=1689"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}