สินค้า

เครื่องสร้างตัวแปรไฟฟ้าสถิตแบบ SVG

Our static reactive power compensators (SVG) provide an optimal solution for issues related to network stability, power factor, and reactive power demand in various industrial applications. The devices feature extremely fast operation, compact design, and exceptional cost efficiency, ensuring immediate response to disturbances in medium- and low-voltage power systems. By compensating reactive power, they significantly increase the lifespan of installations, enhance the reliability of production processes, improve system performance, and reduce transmission losses, all while meeting the most stringent energy quality standards.

ภาพรวม
ดาวน์โหลด

รายละเอียดสินค้า

The consumption of reactive power involves additional charges levied by operators, which is why the use of an SVG compensator effectively reduces electricity bills, completely eliminating the costs associated with reactive power consumption.

  • Immediate and precise reactive power compensation
  • Active harmonic suppression
  • Dynamic adaptation to changing operating conditions

SVG principle of operation

The operating principle of the SVG compensator is based on continuously monitoring the current and voltage waveforms in the network.

When the system detects phase deviations caused by the nature of the load, it immediately generates a compensating current with the opposite characteristics. Thanks to the use of German IGBT modules from Infineon and precise PWM control, the device corrects the power factor in real time, compensating both inductive and capacitive reactive power. This active mode of operation ensures the maintenance of ideal power supply parameters regardless of load fluctuations, guaranteeing exceptional reliability and the highest precision of compensation.

Wall-Mounted SVG

Technical Specification

TYPE Series 230V Series 400V Series 500V Series 690V
ความจุ 20kVar/30kVar/35kVar/
50kVar/70kVar/100kVar
10kVar/15kVar/20kVar/
30kVar/35kVar/50kVar/
75kVar/100kVar/150kVar
85kVar 120kVar
แรงดันไฟฟ้า 230V(+/-20%) 400V(+/-20%) 500V(+/-20%) 690V(+/-20%)
ความถี่ 50Hz(+/-5%)
Phase 1 Phase 3 Phases
เวลาในการตอบกลับ <10ms
compensation factor >95%
Device efficiency >97%
Switching frequency 32kHz 16kHz 12,8kHz 12,8kHz
Function การชดเชยกำลังไฟฟ้ารีแอคทีฟ
Number of modules No limitations. One monitoring module can be
equipped with 32 actuator/execution modules
Communication Dual-channel RS485 (Support for wireless WiFi/GPRS communication)
Altitude above sea level <2000ม.
อุณหภูมิ -20~+50C
Humidity <90%
Pollution Degree Below Level 2
Protections Overload,Over current,Over voltage,Against supply network asymmetry,
Thermal/Over temperature,Frequency fluctuations Short-circuit
Noise <50dB <60dB <65dB
Installation method Wall Mounting
Connection From the top (Wall-mounted)
Degree of protection IP20

Product Size Information

โมเดล Capacity(kvar) Voltage(V) Size(W*H*D)(mm) Cooling
SVG-0.23-2L-W 20Kvar/30Kvar/35Kvar 230V 380x424x88 Forced Air Cooling
SVG-0.23-2L-W 50Kvar/70Kvar/100Kvar 230V 500x550x130 Forced Air Cooling
SVG-0.4-4L-W 10Kvar/15Kvar/20Kvar/30Kvar/35Kvar 400V 380x424x88 Forced Air Cooling
SVG-0.4-4L-W 50Kvar/75Kvar/100Kvar/150Kvar 400V 500x550x130 Forced Air Cooling
SVG-0.5-4L-W 85Kvar 500V 500x550x130 Forced Air Cooling
SVG-0.69-4L-W 120Kvar 690V 500x550x130 Forced Air Cooling

The specification is limited to standard types; other dimensions are available upon request.

Rack-mounted SVG

Technical Specification

TYPE Series 230V Series 400V Series 500V Series 690V
ความจุ 20kVar/30kVar/35kVar/
50kVar/70kVar/100kVar
10kVar/15kVar/20kVar/
30kVar/35kVar/50kVar/
75kVar/100kVar/150kVar
85kVar 120kVar
แรงดันไฟฟ้า 230V(+/-20%) 400V(+/-20%) 500V(+/-20%) 690V(+/-20%)
ความถี่ 50Hz(+/-5%)
Phase 1 Phase 3 Phases
เวลาในการตอบกลับ <10ms
compensation factor >95%
Device efficiency >97%
Switching frequency 32kHz 16kHz 12,8kHz 12,8kHz
Function การชดเชยกำลังไฟฟ้ารีแอคทีฟ
Number of modules No limitations. One monitoring module can be
equipped with 32 actuator/execution modules
Communication Dual-channel RS485 (Support for wireless WiFi/GPRS communication)
Altitude above sea level <2000ม.
อุณหภูมิ -20~+50C
Humidity <90%
Pollution Degree Below Level 2
Protections Overload,Over current,Over voltage,Against supply network asymmetry,
Thermal/Over temperature,Frequency fluctuations Short-circuit
Noise <50dB <60dB <65dB
Installation method Rack-mount
Connection From the back (Rack)
Degree of protection IP20

Product Size Information

โมเดล Capacity(kvar) Voltage(V) Size(W*H*D)(mm) Cooling
SVG-0.23-2L-R 20Kvar/30Kvar/35Kvar 230V 380x424x88 Forced Air Cooling
SVG-0.23-2L-R 50Kvar/70Kvar/100Kvar 230V 500x550x130 Forced Air Cooling
SVG-0.4-4L-R 10Kvar/15Kvar/20Kvar/30Kvar/35Kvar 400V 380x424x88 Forced Air Cooling
SVG-0.4-4L-R 50Kvar/75Kvar/100Kvar/150Kvar 400V 500x550x130 Forced Air Cooling
SVG-0.5-4L-R 85Kvar 500V 500x550x130 Forced Air Cooling
SVG-0.69-4L-R 120Kvar 690V 500x550x130 Forced Air Cooling

The specification is limited to standard types; other dimensions are available upon request.

ขอใบเสนอราคาแบบกำหนดเอง

สนใจผลิตภัณฑ์นี้ใช่ไหม กรุณากรอกแบบฟอร์มด้านล่างแล้วทีมขายของเราจะติดต่อกลับภายใน 24 ชั่วโมง.

แบบฟอร์มผลิตภัณฑ์