AHF active harmonic filters improve power quality and equipment reliability through harmonic control, reducing economic losses caused by equipment failures. They reduce line heating and insulation aging, enhancing electrical safety and reliability, while also reducing the resonance probability of compensation capacitors, ensuring power safety and compliance with national standards. The device reduces electromagnetic interference caused by harmonics, ensuring the normal operation of communication systems.

Overview
Downloads
Video Display

Product Description

The AHF active power filter can effectively monitor harmonics and extract harmonic currents from them. The device emits inverse harmonic currents through IGBT, completely suppressing harmonics at the device connection point, and avoiding greater losses caused by harmonics flowing into circuit breakers or transformers. At the same time, the device can also manage reactive power and three-phase imbalance phenomena, truly achieving intelligent integrated power quality management. AHF can effectively filter out 2–50 harmonics.

  • Improve the quality of power supply, improve the reliability of equipment operation, and reduce economic losses caused by equipment malfunctions
  • Reduce line heating, reduce insulation aging, and improve electrical safety and reliability
  • Reduce the resonance probability of compensation capacitors and improve electricity safety; Meet the requirements of national standards
  • Reduce electromagnetic interference caused by harmonics and ensure the normal operation of the communication system

 

 

AHF principle of operation:

The AHF operates by continuously monitoring the load current in real time using external current transformers (CTs). Its internal high-speed digital signal processor (DSP) extracts harmonic components and reactive current from the detected waveform, then generates a precise, opposite-phase compensation current. This compensating current is injected back into the power line through an insulated-gate bipolar transistor (IGBT) inverter, effectively canceling the harmonics and correcting the power factor. As a result, the AHF ensures that only the fundamental current at nearunity power factor is drawn from the utility, delivering clean, stable power to the grid.

Wall-Mounted AHF

Technical Specification

TYPE Series 230V Series 400V Series 500V Series 690V
Capacity 30A/50A/75A
100A/150A/200A
30A/50A/75A
100A/150A/200A
30A/50A/75A
100A/150A/200A
30A/50A/75A
100A/150A
Voltage 230V(+/-20%) 400V(+/-20%) 500V(+/-20%) 690V(+/-20%)
Frequency 50Hz(+/-5%)
Phase 3 Phases
Response time <5ms
Current transformer 150:5~10,000:5
Efficiency & Losses Efficiency ≥97% (3ph), ≤15 W/A Loss
Function Elimination of harmonic
Number of modules No limitations. One monitoring module can be equipped with 32 actuator/execution modules
Communications protocol Modbus, TCP/IP, CAN
Altitude above sea level <2000m
Temperature -20~+50C
Humidity <90%
Pollution Degree Below Level 2
Compensation mode Harmonic suppression/reactive power compensation/unbalance compensation,

11 modes in any combination

Noise <50dB <60dB <65dB
Installation method Wall Mounting
Standards compliance IEEE519、IEC6100-3-6、ER G5/4、CE,EMC Compliance: EN 61000-6-4 Class A
Degree of protection IP20

Product Size Information

Model Capacity(kvar) Voltage(V) Size(W*H*D)(mm) Cooling
AHF-0.23-3L-W 30A/50A/75A/100A/150A/200A 230V 480x570x175 Forced Air Cooling
AHF-0.23-3L-W 30A/50A/75A/100A/150A/200A 230V 480x570x175 Forced Air Cooling
AHF-0.4-4L-W 30A/50A/75A/100A/150A/200A 400V 480x570x175 Forced Air Cooling
AHF-0.4-4L-W 30A/50A/75A/100A/150A/200A 400V 480x570x175 Forced Air Cooling
AHF-0.5-4L-W 30A/50A/75A/100A/150A/200A 500V 480x570x175 Forced Air Cooling
AHF-0.69-4L-W 30A/50A/75A/100A/150A 690V 480x570x175 Forced Air Cooling

The specification is limited to standard types; other dimensions are available upon request.

Rack Mounted AHF

Technical Specification

TYPE Series 230V Series 400V Series 500V Series 690V
Capacity 30A/50A/75A
100A/150A/200A
30A/50A/75A
100A/150A/200A
30A/50A/75A
100A/150A/200A
30A/50A/75A
100A/150A
Voltage 230V(+/-20%) 400V(+/-20%) 500V(+/-20%) 690V(+/-20%)
Frequency 50Hz(+/-5%)
Phase 3 Phases
Response time <5ms
Current transformer 150:5~10,000:5
Efficiency & Losses Efficiency ≥97% (3ph), ≤15 W/A Loss
Function Elimination of harmonic
Number of modules No limitations. One monitoring module can be equipped with 32 actuator/execution modules
Communications protocol Modbus, TCP/IP, CAN
Altitude above sea level <2000m
Temperature -20~+50C
Humidity <90%
Pollution Degree Below Level 2
Compensation mode Harmonic suppression/reactive power compensation/unbalance compensation, 11 modes in any combination
Noise <50dB <60dB <65dB
Installation method Rack Mounting
Standards compliance IEEE519、IEC6100-3-6、ER G5/4、CE,EMC Compliance: EN 61000-6-4 Class A
Degree of protection IP20

Product Size Information

Model Capacity(kvar) Voltage(V) Size(W*H*D)(mm) Cooling
AHF-0.23-3L-W 30A/50A/75A/100A/150A/200A 230V 480x570x175 Forced Air Cooling
AHF-0.23-3L-W 30A/50A/75A/100A/150A/200A 230V 480x570x175 Forced Air Cooling
AHF-0.4-4L-W 30A/50A/75A/100A/150A/200A 400V 480x570x175 Forced Air Cooling
AHF-0.4-4L-W 30A/50A/75A/100A/150A/200A 400V 480x570x175 Forced Air Cooling
AHF-0.5-4L-W 30A/50A/75A/100A/150A/200A 500V 480x570x175 Forced Air Cooling