Ürünler

Statik Var Jeneratörü (SVG) & Gelişmiş Statik Var Jeneratörü (ASVG)

Our static reactive power compensators (SVG) provide an optimal solution for issues related to network stability, power factor, and reactive power demand in various industrial applications. The devices feature extremely fast operation, compact design, and exceptional cost efficiency, ensuring immediate response to disturbances in medium- and low-voltage power systems. By compensating reactive power, they significantly increase the lifespan of installations, enhance the reliability of production processes, improve system performance, and reduce transmission losses, all while meeting the most stringent energy quality standards.

Genel Bakış
İndirilenler

Ürün Açıklaması

The consumption of reactive power involves additional charges levied by operators, which is why the use of an SVG compensator effectively reduces electricity bills, completely eliminating the costs associated with reactive power consumption.

  • Immediate and precise reactive power compensation
  • Active harmonic suppression
  • Dynamic adaptation to changing operating conditions

SVG principle of operation

The operating principle of the SVG compensator is based on continuously monitoring the current and voltage waveforms in the network.

When the system detects phase deviations caused by the nature of the load, it immediately generates a compensating current with the opposite characteristics. Thanks to the use of German IGBT modules from Infineon and precise PWM control, the device corrects the power factor in real time, compensating both inductive and capacitive reactive power. This active mode of operation ensures the maintenance of ideal power supply parameters regardless of load fluctuations, guaranteeing exceptional reliability and the highest precision of compensation.

Wall-Mounted SVG

Teknik Şartname

TİP Seri 230V Seri 400V Seri 500V Seri 690V
Kapasite 20kVar/30kVar/35kVar/
50kVar/70kVar/100kVar
10kVar/15kVar/20kVar/
30kVar/35kVar/50kVar/
75kVar/100kVar/150kVar
85kVar 120kVar
Voltaj 230 V (+/-20%) 400 V (+/-20%) 500 V (+/-20%) 690 V (+/-201 TP3T)
Frekans 50 Hz (+/-5%)
Evre 1 Phase 3 Aşama
Yanıt süresi <10ms
compensation factor >95%
Device efficiency >97%
Switching frequency 32kHz 16kHz 12,8kHz 12,8kHz
İşlev Reaktif güç kompanzasyonu
Modül sayısı No limitations. One monitoring module can be
equipped with 32 actuator/execution modules
Communication Dual-channel RS485 (Support for wireless WiFi/GPRS communication)
Deniz seviyesinden yükseklik <2000m
Sıcaklık -20~+50°C
Nem <90%
Kirlilik Derecesi Seviye 2'nin altında
Protections Overload,Over current,Over voltage,Against supply network asymmetry,
Thermal/Over temperature,Frequency fluctuations Short-circuit
Gürültü <50dB <60dB <65dB
Kurulum yöntemi Duvara Montaj
Connection From the top (Wall-mounted)
Koruma derecesi IP20

Ürün Boyut Bilgileri

Model Kapasite (kvar) Gerilim(V) Boyutlar(G*Y*D)(mm) Soğutma
SVG-0.23-2L-W 20Kvar/30Kvar/35Kvar 230V 380x424x88 Zorlamalı Hava Soğutma
SVG-0.23-2L-W 50Kvar/70Kvar/100Kvar 230V 500x550x130 Zorlamalı Hava Soğutma
SVG-0.4-4L-W 10Kvar/15Kvar/20Kvar/30Kvar/35Kvar 400V 380x424x88 Zorlamalı Hava Soğutma
SVG-0.4-4L-W 50Kvar/75Kvar/100Kvar/150Kvar 400V 500x550x130 Zorlamalı Hava Soğutma
SVG-0.5-4L-W 85Kvar 500V 500x550x130 Zorlamalı Hava Soğutma
SVG-0.69-4L-W 120Kvar 690V 500x550x130 Zorlamalı Hava Soğutma

Şartname standart tiplerle sınırlıdır; diğer boyutlar talep üzerine temin edilebilir.

Rack-mounted SVG

Teknik Şartname

TİP Seri 230V Seri 400V Seri 500V Seri 690V
Kapasite 20kVar/30kVar/35kVar/
50kVar/70kVar/100kVar
10kVar/15kVar/20kVar/
30kVar/35kVar/50kVar/
75kVar/100kVar/150kVar
85kVar 120kVar
Voltaj 230 V (+/-20%) 400 V (+/-20%) 500 V (+/-20%) 690 V (+/-201 TP3T)
Frekans 50 Hz (+/-5%)
Evre 1 Phase 3 Aşama
Yanıt süresi <10ms
compensation factor >95%
Device efficiency >97%
Switching frequency 32kHz 16kHz 12,8kHz 12,8kHz
İşlev Reaktif güç kompanzasyonu
Modül sayısı No limitations. One monitoring module can be
equipped with 32 actuator/execution modules
Communication Dual-channel RS485 (Support for wireless WiFi/GPRS communication)
Deniz seviyesinden yükseklik <2000m
Sıcaklık -20~+50°C
Nem <90%
Kirlilik Derecesi Seviye 2'nin altında
Protections Overload,Over current,Over voltage,Against supply network asymmetry,
Thermal/Over temperature,Frequency fluctuations Short-circuit
Gürültü <50dB <60dB <65dB
Kurulum yöntemi Rack-mount
Connection From the back (Rack)
Koruma derecesi IP20

Ürün Boyut Bilgileri

Model Kapasite (kvar) Gerilim(V) Boyutlar(G*Y*D)(mm) Soğutma
SVG-0.23-2L-R 20Kvar/30Kvar/35Kvar 230V 380x424x88 Zorlamalı Hava Soğutma
SVG-0.23-2L-R 50Kvar/70Kvar/100Kvar 230V 500x550x130 Zorlamalı Hava Soğutma
SVG-0.4-4L-R 10Kvar/15Kvar/20Kvar/30Kvar/35Kvar 400V 380x424x88 Zorlamalı Hava Soğutma
SVG-0.4-4L-R 50Kvar/75Kvar/100Kvar/150Kvar 400V 500x550x130 Zorlamalı Hava Soğutma
SVG-0.5-4L-R 85Kvar 500V 500x550x130 Zorlamalı Hava Soğutma
SVG-0.69-4L-R 120Kvar 690V 500x550x130 Zorlamalı Hava Soğutma

Şartname standart tiplerle sınırlıdır; diğer boyutlar talep üzerine temin edilebilir.

SVG / ASVG product-resource hub

Static Var Generator (SVG) and Advanced Static Var Generator (ASVG) are product-line terms for dynamic reactive-power compensation projects. CNBYG evaluates the required response, reactive-power range, connection conditions, load variation, existing equipment, and installation constraints with the project data. A product page is not a guarantee of power-factor, voltage, or compliance performance.

Discuss an SVG/ASVG application

Application entry points

Marine and shipbuilding

Review shore-power, welding, and installation constraints for the relevant vessel or yard project.

SVG / ASVG selection inputs

  • Single-line diagram, nominal voltage, frequency, transformer capacity, and installation location
  • Reactive-power profile, power-factor objective, load variation, and relevant voltage data
  • Existing capacitor banks, reactors, filtering equipment, protection, and control interfaces
  • Environmental, enclosure, thermal, cable, and commissioning constraints

For systems with a separate harmonic-current issue, review the AHF/APF ürün merkezi and determine whether the objectives require coordinated equipment.

Seçilen teknik kaynaklar

Proje önerisinde bulunmadan önce teknik soruyu çerçevelemek için bu makaleleri kullanın.

Manufacturer and RFQ information

For a manufacturer discussion, provide the project electrical data and installation constraints rather than requesting a rating from a keyword alone. CNBYG can discuss product-line availability, technical documentation, and project inputs through the İletişim sayfası.

Sık sorulan sorular

Is SVG suitable for all reactive-power applications?

No. Suitability depends on the electrical system, required response, load profile, existing equipment, and project requirements.

What does “ASVG” mean on this site?

It is CNBYG’s Advanced Static Var Generator product terminology. Confirm functions and configuration against the applicable product documentation and application data.

Özel Teklif İste

Bu ürünle ilgileniyor musunuz? Aşağıdaki formu doldurun, satış ekibimiz 24 saat içinde sizinle iletişime geçecektir.

Ürün Formu