BYFK composite switch is a combination of intelligent chips, digital circuits, and magnetic holding relays to achieve voltage zero crossing conduction and current zero crossing cutoff, allowing the switch to fulyswitch to zero crossing at the moment of turing on and off, without generating over voltage. Switches have many advantages such as no inrush current, extremely low power consumption, high lifespan, and low fault rate, and are widely used in the field of low-voltage reactive power compensation.
Protection Function
Low Power Consumption
The relay only consumes electricity at the moment of switching, and does not consume electricity during normal times, thus achieving energy conservation and consumption reduction.
Job Security
All control input signals and internal circuits are safely isolated, and advanced intelligent control technology and patented devices are adopted. Compared with similar products, it has extremely high performance advantages in surge current and safety reliability.
After receiving external control signals, through intelligent judgment, the optimal switching point is automaticallv found to ensure zero crossina switchina, low inrush current, non sintering of contacts, owenergy consumption, and has functions such as voltage anomaly protection, phase loss protection.component fault protection,and operation indication.Compared with similar products, the BYFK series of intelligent low-voltage composite switches greatly improve their inrush current and safety reliability.
| Project | Parameter |
| Ambient temperature | -20℃~+55℃ |
| Relative humidity | At 40℃,20%~90% |
| Rated voltage | 380V/220V three-phase four wire AC 50Hz The synchronous change of three-phase voltage shall |
| Allowable deviation | not exceed ± 20% |
| Voltage distortion rate | <5% |
| Rated frequency | 50HZ |
| Rated current | <80A(Ordinary type); <80A(With circuit breaker type) |
| Service life | 500000 times |
| Phase number | A Delta connection method (three-phase); Y-shaped connection method (single-phase) |
| Three phase control capacity | <40Kvar |
| Single-phase control capacity | <10Kvar |
| power dissipation | <1.5VA |
| Contact pressure drop | <100mV |
| Contact withstand voltage | >1600V |
| Response time | <1000ms |
| Interval between each turn on and turn off | >5 Second |
| Interval between two consecutive connections | =35 Second |
| Control signal | DC12V±20%; Exchange/Communication (Optional) |
| Input impedance | >6.8K |
| Conduction impedance | <0.0032 |
| Inrush current | Less than 1.5 times the rated current |
| Rated current of feedback contact | 1A (put on as connected) |


Interested in this product? Fill out the form below and our sales team will get back to you within 24 hours.