Produk

Static Var Generator (SVG) & Advanced Static Var Generator (ASVG)

Our static reactive power compensators (SVG) provide an optimal solution for issues related to network stability, power factor, and reactive power demand in various industrial applications. The devices feature extremely fast operation, compact design, and exceptional cost efficiency, ensuring immediate response to disturbances in medium- and low-voltage power systems. By compensating reactive power, they significantly increase the lifespan of installations, enhance the reliability of production processes, improve system performance, and reduce transmission losses, all while meeting the most stringent energy quality standards.

Ikhtisar
Unduhan

Deskripsi Produk

The consumption of reactive power involves additional charges levied by operators, which is why the use of an SVG compensator effectively reduces electricity bills, completely eliminating the costs associated with reactive power consumption.

  • Immediate and precise reactive power compensation
  • Active harmonic suppression
  • Dynamic adaptation to changing operating conditions

SVG principle of operation

The operating principle of the SVG compensator is based on continuously monitoring the current and voltage waveforms in the network.

When the system detects phase deviations caused by the nature of the load, it immediately generates a compensating current with the opposite characteristics. Thanks to the use of German IGBT modules from Infineon and precise PWM control, the device corrects the power factor in real time, compensating both inductive and capacitive reactive power. This active mode of operation ensures the maintenance of ideal power supply parameters regardless of load fluctuations, guaranteeing exceptional reliability and the highest precision of compensation.

Wall-Mounted SVG

Spesifikasi Teknis

KETIK Seri 230V Seri 400V Seri 500V Seri 690V
Kapasitas 20kVar/30kVar/35kVar/
50kVar/70kVar/100kVar
10kVar/15kVar/20kVar/
30kVar/35kVar/50kVar/
75kVar/100kVar/150kVar
85kVar 120kVar
Tegangan 230 V (+/-20%) 400 V (+/-20%) 500 V (+/-201 TP3T) 690 V (+/-201 TP3T)
Frekuensi 50 Hz (+/-51 TP3T)
Fase 1 Phase 3 Fase
Waktu respons <10ms
compensation factor >95%
Device efficiency >97%
Switching frequency 32kHz 16kHz 12,8kHz 12,8kHz
Fungsi Kompensasi daya reaktif
Jumlah modul No limitations. One monitoring module can be
equipped with 32 actuator/execution modules
Communication Dual-channel RS485 (Support for wireless WiFi/GPRS communication)
Ketinggian di atas permukaan laut <2000m
Suhu -20 hingga +50 °C
Kelembapan <90%
Tingkat Polusi Di Bawah Level 2
Protections Overload,Over current,Over voltage,Against supply network asymmetry,
Thermal/Over temperature,Frequency fluctuations Short-circuit
Kebisingan <50dB <60dB <65dB
Metode instalasi Pemasangan di Dinding
Connection From the top (Wall-mounted)
Derajat perlindungan IP20

Informasi Ukuran Produk

Model Kapasitas (kvar) Tegangan (V) Ukuran (P×T×L) (mm) Pendinginan
SVG-0.23-2L-W 20Kvar/30Kvar/35Kvar 230V 380x424x88 Pendinginan Udara Paksa
SVG-0.23-2L-W 50Kvar/70Kvar/100Kvar 230V 500x550x130 Pendinginan Udara Paksa
SVG-0.4-4L-W 10Kvar/15Kvar/20Kvar/30Kvar/35Kvar 400V 380x424x88 Pendinginan Udara Paksa
SVG-0.4-4L-W 50Kvar/75Kvar/100Kvar/150Kvar 400V 500x550x130 Pendinginan Udara Paksa
SVG-0.5-4L-W 85Kvar 500V 500x550x130 Pendinginan Udara Paksa
SVG-0.69-4L-W 120Kvar 690V 500x550x130 Pendinginan Udara Paksa

Spesifikasi terbatas pada jenis standar; dimensi lain tersedia berdasarkan permintaan.

Rack-mounted SVG

Spesifikasi Teknis

KETIK Seri 230V Seri 400V Seri 500V Seri 690V
Kapasitas 20kVar/30kVar/35kVar/
50kVar/70kVar/100kVar
10kVar/15kVar/20kVar/
30kVar/35kVar/50kVar/
75kVar/100kVar/150kVar
85kVar 120kVar
Tegangan 230 V (+/-20%) 400 V (+/-20%) 500 V (+/-201 TP3T) 690 V (+/-201 TP3T)
Frekuensi 50 Hz (+/-51 TP3T)
Fase 1 Phase 3 Fase
Waktu respons <10ms
compensation factor >95%
Device efficiency >97%
Switching frequency 32kHz 16kHz 12,8kHz 12,8kHz
Fungsi Kompensasi daya reaktif
Jumlah modul No limitations. One monitoring module can be
equipped with 32 actuator/execution modules
Communication Dual-channel RS485 (Support for wireless WiFi/GPRS communication)
Ketinggian di atas permukaan laut <2000m
Suhu -20 hingga +50 °C
Kelembapan <90%
Tingkat Polusi Di Bawah Level 2
Protections Overload,Over current,Over voltage,Against supply network asymmetry,
Thermal/Over temperature,Frequency fluctuations Short-circuit
Kebisingan <50dB <60dB <65dB
Metode instalasi Rack-mount
Connection From the back (Rack)
Derajat perlindungan IP20

Informasi Ukuran Produk

Model Kapasitas (kvar) Tegangan (V) Ukuran (P×T×L) (mm) Pendinginan
SVG-0.23-2L-R 20Kvar/30Kvar/35Kvar 230V 380x424x88 Pendinginan Udara Paksa
SVG-0.23-2L-R 50Kvar/70Kvar/100Kvar 230V 500x550x130 Pendinginan Udara Paksa
SVG-0.4-4L-R 10Kvar/15Kvar/20Kvar/30Kvar/35Kvar 400V 380x424x88 Pendinginan Udara Paksa
SVG-0.4-4L-R 50Kvar/75Kvar/100Kvar/150Kvar 400V 500x550x130 Pendinginan Udara Paksa
SVG-0.5-4L-R 85Kvar 500V 500x550x130 Pendinginan Udara Paksa
SVG-0.69-4L-R 120Kvar 690V 500x550x130 Pendinginan Udara Paksa

Spesifikasi terbatas pada jenis standar; dimensi lain tersedia berdasarkan permintaan.

SVG / ASVG product-resource hub

Static Var Generator (SVG) and Advanced Static Var Generator (ASVG) are product-line terms for dynamic reactive-power compensation projects. CNBYG evaluates the required response, reactive-power range, connection conditions, load variation, existing equipment, and installation constraints with the project data. A product page is not a guarantee of power-factor, voltage, or compliance performance.

Discuss an SVG/ASVG application

Application entry points

Marine and shipbuilding

Review shore-power, welding, and installation constraints for the relevant vessel or yard project.

SVG / ASVG selection inputs

  • Single-line diagram, nominal voltage, frequency, transformer capacity, and installation location
  • Reactive-power profile, power-factor objective, load variation, and relevant voltage data
  • Existing capacitor banks, reactors, filtering equipment, protection, and control interfaces
  • Environmental, enclosure, thermal, cable, and commissioning constraints

For systems with a separate harmonic-current issue, review the AHF/APF product hub and determine whether the objectives require coordinated equipment.

Selected technical resources

Use these articles to frame the technical question before requesting a project recommendation.

Manufacturer and RFQ information

For a manufacturer discussion, provide the project electrical data and installation constraints rather than requesting a rating from a keyword alone. CNBYG can discuss product-line availability, technical documentation, and project inputs through the halaman kontak.

Pertanyaan yang sering diajukan

Is SVG suitable for all reactive-power applications?

No. Suitability depends on the electrical system, required response, load profile, existing equipment, and project requirements.

What does “ASVG” mean on this site?

It is CNBYG’s Advanced Static Var Generator product terminology. Confirm functions and configuration against the applicable product documentation and application data.

Minta Penawaran Kustom

Tertarik dengan produk ini? Isi formulir di bawah ini dan tim penjualan kami akan segera menghubungi Anda dalam waktu 24 jam.

Formulir Produk